60W Ultra Slim Step Shape DIN Rail HDR-60 series Bauar t gepruft Sicherheit egel ma ge od o s be wac g UL508 UL60950-1 www. tuv.com ID 2000000000 EN61558 R33100 RoHS TPTC004 AS/NZS60950-1 IEC60950-1 Features Ultra slim design with 52.5mm(3SU) width Universal input 85~264VAC(277VAC operational) No load power consumption<0.3W Isolation class Pass LPS (Limited power source) DC output voltage adjustable Protections : Short circuit / Overload / Over voltage Cooling by free air convection (working temperature:-30~+70C) DIN rail TS-35/7.5 or 15 mountable Over voltage category LED indicator for power on 3 years warranty Applications Household control system Building automation Industrial control system Factory automation Electro-mechanical apparatus Description HDR-60 is one economical ultra slim 60W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 52.5mm(3SU) in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 85VAC to 264VAC (277VAC operational) and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current. HDR-60 is designed with plastic housing that it can effectively prevent user from electric hazards. With working efficiency up to 91%, the entire series can operate at the ambient temperature between -30 and 70 under air convection. The complete protection functions and relevant certificates for home automations and industrial control apparatus (IEC60950-1,UL508,UL60950-1,EN61558-2-16) make HDR-60 a very competitive power supply solution for household and industrial applications. Model Encoding HDR - 60 - 12 Output voltage Rated wattage Series name File Name:HDR-60-SPEC 2019-06-26 HDR-60 60W Ultra Slim Step Shape DIN Rail series SPECIFICATION MODEL HDR-60-5 INPUT HDR-60-15 HDR-60-24 HDR-60-48 DC VOLTAGE 5V 12V 15V 24V 48V RATED CURRENT 6.5A 4.5A 4A 2.5A 1.25A CURRENT RANGE 0 ~ 6.5A 32.5W 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A 54W 60W 60W 60W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p VOLTAGE ADJ. RANGE 10.8 ~ 13.8V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V RATED POWER OUTPUT HDR-60-12 5.0 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 50ms/230VAC HOLD UP TIME (Typ.) 30ms/230VAC VOLTAGE RANGE 85 ~ 264VAC (277VAC operational ) FREQUENCY RANGE 47 ~ 63Hz 90% 91% 500ms, 50ms/115VAC at full load 12ms/115VAC at full load 120 ~ 370VDC (390VDC operational ) EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.2A/115VAC 0.8A/230VAC COLD START 30A/115VAC 60A/230VAC OVERLOAD Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed 5.75 ~ 6.75V 56.5 ~ 64.8V 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 88% 89% 105 ~ 160% rated output power PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing 0.03%/ (0 ~ 50) RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters OVER VOLTAGE CATEGORY ; According to E N 61558, EN50178,EN60664-1, EN62477-1 ; altitude up to 2000 meters SAFETY STANDARDS WITHSTAND VOLTAGE UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN60950-1 I/P-O/P:4KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Standard Parameter Conducted EMC EMISSION SAFETY & EMC (Note 4) Radiated Harmonic Current MTBF OTHERS DIMENSION PACKING NOTE Class B EN61000-3-2 Class A Class B ------- Voltage Flicker EN61000-3-3 EN55024, EN55035, EN61000-6-2, EN61204-3 Parameter Standard Test Level /Note ESD Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility EMC IMMUNITY Test Level / Note EN55032(CISPR32), CNS13438 EN55032(CISPR32), CNS13438 EFT/Burest Surge EN61000-4-2 EN61000-4-3 EN61000-4-4 Conducted Magnetic Field EN61000-4-5 EN61000-4-6 EN61000-4-8 Voltage Dips and interruptions EN61000-4-11 Level 3, criteria A Level 3, criteria A Level 4,2KV/L-N, criteria A Level 3, criteria A Level 4, criteria A 95% dip 0. 5 periods, 30% dip 25 periods, 95% interruptions 250 periods 927.6K hrs min. MIL-HDBK-217F (25) 52.5*90*54.5mm (W*H*D) 190g;60pcs/12.4Kg/0.97CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:HDR-60-SPEC 2019-06-26 HDR-60 60W Ultra Slim Step Shape DIN Rail series Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (VERTICAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 277 (operational) INPUT VOLTAGE (VAC) 60Hz File Name:HDR-60-SPEC 2019-06-26 HDR-60 60W Ultra Slim Step Shape DIN Rail series Mechanical Specification ( Unit: mm , tolerance 0.5mm) 58.4 54.5 52.5 4 5 45.15 3 63.65 2 90 1 6 35 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin No. Assignment Pin No. Assignment Pin No. Assignment 1,2 -V 5 AC/L 3,4 +V 6 AC/N Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:HDR-60-SPEC 2019-06-26