8
Selection
Selection table
Selection criteria
b Functions (On-delay or Off-delay, counter, repeat)
b Supply voltage (example: a/c 12–240 V).
b Timing range for a timing relay (example: 0.05 s–100 h)
b Type of output (contact or solid state) and required Number of contacts.
b Breaking capacity or Rated current of contacts, expressed in amperes.
This is the maximum current which may ow through the contacts.
Functions Timing
range
Supply
voltage
Type of
output
Rated
current
Relay
A0.1 s–100 h c 12 V 2 C/O contacts 5 A REXL2TMJD
4 C/O contacts 3 A REXL4TMJD
0.1 s–100 h c 24 V 2 C/O contacts 5 A REXL2TMBD
4 C/O contacts 3 A REXL4TMBD
0.1 s–100 h a 24 V 2 C/O contacts 5 A REXL2TMB7
4 C/O contacts 3 A REXL4TMB7
0.1 s–100 h a 120 V 2 C/O contacts 5 A REXL2TMF7
4 C/O contacts 3 A REXL4TMF7
0.1 s–100 h a 230 V 2 C/O contacts 5 A REXL2TMP7
4 C/O contacts 3 A REXL4TMP7
0.1–10 s a/c 24–240 V 1 solid state output 0.7 A RE9TA11MW
0.3–30 s 0.7 A RE9TA31MW
3–300 s 0.7 A RE9TA21MW
40 s–60 min 0.7 A RE9TA51MW
1 s–100 h 0.7 A RE17LAMW
0.02 s–300 h 2 timed C/O contacts 5 A RE48ATM12MW
0.05 s–300 h a/c 24 V, a 110–240 V 1 C/O contact 8 A RE7TL11BU
0.1–3 s 8 A RE8TA61BUTQ
0.1–10 s 8 A RE8TA11BUTQ
0.3–30 s 8 A RE8TA31BUTQ
3 s–300 s 8 A RE8TA21BUTQ
20–30 min 8 A RE8TA41BUTQ
0.05 s–300 h a/c 24 V, a 110–240 V,
a/c 42–48 V
2 C/O contacts 8 A RE7TP13BU
A, Ac, At, B, Bw, C, D, Di, H, Ht 1 s–100 h a 24–240 V 1 solid state output 0.7 A RE17LMBM
1 s–100 h a/c 12 V 1 C/O contact 8 A RE17RMJU
1 s–100 h a/c 12–240 V 1 C/O contact 8 A RE17RMMW
8 A RE17RMMWS
1 s–100 h c 24 V, a 24–240 V 1 C/O contact 8 A RE17RMMU
A, At 1 s–100 h c 24 V, a 24–240 V 1 C/O contact 8 A RE17RAMU
A, At, Aw 0.05 s–300 h a 110–240 V, a/c 24 V,
a/c 42–48 V
1 C/O contact 8 A RE7TM11BU
A, At, B, C, D, Di, H, Ht 1 s–10 h c 24 V, a 24–240 V 1 C/O contact 5 A RE17RMEMU
A, B, C, Di 0.02 s–300 h a/c 24–240 V 2 C/O contacts 5 A RE48AML12MW
A, C, D, Di, H, Qg, Qt, W 0.05 s–300 h a 110–240 V, a/c 24 V,
a/c 42–48 V
2 C/O contacts 8 A RE7MY13BU
0.05 s–300 h a/c 24–240 V 2 C/O contacts 8 A RE7MY13MW
A, C, D, Di, H, W 0.05 s–300 h a 110–240 V, a/c 24 V,
a/c 42–48 V
1 C/O contact 8 A RE7ML11BU
A, D, Di, H 0.1–10 s and 3–300 s a/c 24–240 V
a 24–240 V
1 solid state output 0.7 A RE9MS21MW
A1, A2, H1, H2 0.02 s–300 h a/c 24–240 V 2 C/O contacts 5 A RE48AMH13MW
Ac 0.05 s–300 h a 110–240 V, a/c 24 V,
a/c 42–48 V
1 C/O contact 8 A RE7MA11BU
2 C/O contacts 8 A RE7MA13BU
Ad, Ah, N, O, P, Pt, T, Tt, W 1 s–100 h c 24 V, a 24–240 V 1 C/O contact 8 A RE17RMXMU
Ak 0.05 s–300 h a 110–240 V, a/c 24 V,
a/c 42–48 V
1 C/O contact 8 A RE7MV11BU
Zelio™ Timing Relays