Q85 Series Long Range Diffuse Sensors ac/dc sensors with e/m relay output and optional timing logic * * * * * * Economical long range diffuse (proximity) sensors in rugged, NEMA-6P (IEC IP67) Cycolac(R) ABS housings Sensing range of 39 inches (1 meter) referenced to a 90% reflectance white test card Operates from 24 to 240 volts ac or 12 to 240 volts dc; totally self-contained Q85VR3DL-T9 sensor with cover removed SPDT electromechanical relay output device; choice of on/off output or programmable timing logic Wiring chamber with two conduit entrances for mounting versatility LED indicators for OUTPUT ON and LIGHT SENSED (AIDTM signal strength indicator system, see text) Q85s are compact, economical, infrared diffuse (proximity) mode photoelectric sensors in rugged NEMA-6P rated ABS housings. They are ideally suited to conveyor control and similar applications. The timing logic functions offered in the "T9" models provide additional control capabilities over and above the basic model's ON/OFF (no delay) function. All Q85 sensors feature a convenient wiring chamber with two conduit entrances for ease of connection, positioning, and mounting. Sensing range is 39 inches (1 meter), referenced to a 90% reflectance white test card. Q85 Series sensors operate from either 24-240V ac or 12-240V dc and draw 2 watts maximum. They have SPDT electromechanical relay output, and are available with a choice of either ON/OFF or programmable timing output logic. Models with programmable timing logic ("T9" models) provide eight switchselectable logic functions: ON/OFF (no delay), ON delay, OFF delay, ON/OFF delay, one-shot (pulse), on-delayed one-shot, limit timer, and on-delayed limit timer. The adjustable time range for delay functions and pulse length is 0.1 to 5 seconds (see page 2). All models feature a SENSITIVITY control for precise adjustment of sensing gain. Two top-mounted LED indicators are provided, and are visible through a window in the wiring chamber's gasketed cover. A red indicator (Banner's exclusive, patented AIDTM system*) lights whenever the sensor "sees" the reflection of its own modulated light source, and pulses at a rate proportional to the strength of the received light signal. A yellow output indicator lights whenever the Q85's output is energized. Q85 Series sensors have rugged yellow Cycolac(R) ABS housings with ultrasonically-welded acrylic lenses. A gasketed ABS cover protects the wiring chamber and the timing and sensitivity adjustment controls inside. Two 1/2-14 NPSM conduit entrances are provided, and a plug and gasket are included for a possible unused entrance. Q85 Series sensors are rated NEMA 1, 2, 3, 3S, 4, 4X, 6, 6P, 12, and 13 (IEC IP67). An 11-gauge plated steel mounting bracket and two plated mounting bolts and nuts (see photo above and drawing on page 2) are included. *Alignment Indicating Device system, US patent number 4356393 Printed in USA Mounting bracket and hardware are included Specifications, Q85 Series Long-range Diffuse Sensors Sensing range: 39 inches (1 meter), referenced to a 90% reflectance white test card. Sensing beam: infrared, 880 nanometers. Supply voltage: 24 to 240V ac, 50/60 Hz or 12 to 240V dc (2 watts maximum). No polarity for power supply hookup. Models and Output Configurations: Q85VR3DL = SPDT e/m relay, on/off output Q85VR3DL-T9 = SPDT e/m relay, with programmable timer Output relay specifications: Maximum switching power (resistive load): 90W, 750VA. Install transient suppressor (MOV) across contacts that switch inductive loads. Maximum switching voltage (resistive load): 250V ac or 30V dc. Maximum switching current (resistive load): 3A. Minimum voltage and current: 5V dc, 10 mA. Mechanical life: 50,000,000 operations. Electrical life at full resistive load: 100,000 operations. Maximum switching speed: 25 operations per second. Closure time (no timing logic in use): 20 milliseconds max. Release time (no timing logic in use): 20 milliseconds max. Repeatability (no timing logic in use): 1 millisecond. All sensors are protected against false pulse on power-up. (False pulse protection circuit causes a 100 millisecond delay on power-up.) Adjustments: All models have a single-turn SENSITIVITY control potentiometer, accessible beneath the ABS wiring chamber cover (T9 models also have a light/dark operate switch). Timing logic (T9 models only) is configured at a DIP switch. Pulse length and delay are set by a single-turn potentiometer (accessible under the wiring chamber cover). The adjustable time range for both functions is 0.1 to 5 seconds; both functions are automatically set to the same value. Status Indicators: LEDs, one red and one yellow, both top-mounted. Red AIDTM system (Alignment Indicating Device, US patent #4356393) indicator LED lights whenever the sensor "sees" its own modulated light, and pulses at a rate proportional to the strength of the light signal. Yellow indicator lights whenever the sensor's output is energized. Construction: Yellow Cycolac(R) ABS housing, plated steel hardware. Acrylic lens. ABS cover for wiring/adjustments access. Rated NEMA 1, 2, 3, 3S, 4, 4X, 6, 6P, 12, and 13; IEC IP67. It is the customer's responsibility to maintain NEMA 6P integrity at the conduit entrance(s) in use. Maximum wire size (for connection to wiring terminals) is #14 AWG. Operating temperature range: -25 to +55C (-13 to +131F). Maximum relative humidity: 90% at 50C (non-condensing). Cycolac(R) is a registered trademark of General Electric Co. P/N 31529L3A Hookup and timing logic selection Hookup to the ac line and the external load is made at the five terminals inside the wiring chamber (see drawing below). There is no polarity for power supply hookup. Output is an SPDT electromechanical relay. Timing logic programming switch detail: 0 L.O. 1 D.O. SW1 SW2 the single-turn time adjustment potentiometer. When the timing function involves more than one time (as in ON and OFF delay, ON-delayed one-shot, and ON-delayed limit timer functions), the potentiometer sets both times to the same value. Logic function Switch: ON and OFF delays (both) ON delay (only) OFF delay (only) No delays ON delayed one-shot ON delayed limit timer One-shot Limit timer SW1 SW2 SW3 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 SW3 The output timing logic function (on sensor models with T9 model number suffix) is selected at the timing logic programming switches, according to the table (right). The output timing logic delays are set at With the light/dark operate switch (T9 models) set to light operate (L.O.), the sensor's electromechanical output relay is energized when the sensor sees the reflection of its own modulated light source. In the dark operate (D.O.) position, the output is energized when the sensor does not see the reflection of its modulated light source. Sensor sensitivity is set at the single-turn sensitivity adjustment potentiometer. Dimensions, Q85 diffuse mode sensors 1000 Top view E X 100 C E S S G A I N Beam Pattern Excess Gain Curve Q85 Series Q85 Series long-range diffuse mode sensors 25 mm Range is referenced to a 90% reflectance white test card 1 in 0 10 25 mm 1 in long-range diffuse sensors 1 .01 m .4 in 0 .1 m 1m 3.9 in 39 in DISTANCE 10 m .2 m 7.9 in .4 m 16 in .6 m 24 in .8 m 31 in 1m 39 in Distance to 90% white test card Shown with mounting bracket (included) Bottom view WARNING This photoelectric presence sensor does NOT include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can result in either an energized or a de-energized sensor output condition. Never use this product as a sensing device for personnel protection. Its use as a safety device may create an unsafe condition which could lead to serious injury or death. Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel protection. WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp. 9714 10th Avenue No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications): (612) 544-3573