2009/10 EDITION MAGNETIC COMPONENTS SELECTOR GUIDE
We reserve the right to change specifications without prior notice.
www.bitechnologies.com
129
Inductance Leakage Peak
Power Output(1) 100kHz, 0.1V Inductance(2) Pri. DCR
Part Rating Vo Io Turns Ratio @ 0A 100kHz, 0.1V Current mW Max.
Number (W) (V) (A) Pri. Sec. Aux. µH Typ. µH Typ. (Adc) Pri. Sec. Aux. Fig.
HM110-5W3V3LF 5 3.3 1.52 1 0.156 0.578 180 1.50 0.65 600 16.0 600 1
HM110-5W5VLF 5 5 1.0 1 0.244 0.578 180 1.40 0.65 600 40.0 600 1
HM110-5W12VLF 5 12 0.42 1 0.578 0.578 180 1.50 0.65 600 213 600 1
HM110-6W3V3LF 6 3.3 2.0 1 0.100 0.400 120 1.50 0.65 600 7.0 250 2
HM110-8W3V3LF 8 3.3 2.42 1 0.176 0.588 100 1.00 1.00 255 8.0 500 3
HM110-8W5VLF 8 5 1.6 1 0.265 0.588 100 1.00 1.00 255 15.0 500 3
HM110-8W12VLF 8 12 0.66 1 0.588 0.588 100 1.00 1.00 255 75.0 500 3
HM110-15W3V3LF 15 3.3 4.55 1 0.143 0.500 70 1.00 1.65 123 8.5 360 4
HM110-15W5VLF 15 5 3.0 1 0.250 0.500 70 0.81 1.65 123 10.5 360 4
HM110-15W12VLF 15 12 1.25 1 0.500 0.500 70 1.00 1.65 123 42.0 360 4
HM110-30W5VLF 30 5 6.0 1 0.125 0.375 38 1.50 3.00 75 4.5 127 5
HM110-40W5VLF 40 5 8.0 1 0.158 0.368 30 1.50 4.00 65 3.0 127 6
Specifications @ 25°C
• OperatingTemperatureRange -40°Cto+125°C
• PowerRating 5Wto40W
• Topology Flyback
• IsolationVoltage 1500Vrms
HM110
Electrical / Environmental
HighFrequencySurfaceMount
PowerOverEthernetTransformers
Notes: (1) Theswitchingfrequencyofthetransformeris250kHz.
(2) Leakageinductanceismeasuredatprimarywithallotherwindingsshorted.
Outline Dimensions (mm) / Schematics
Schematic Top View Recommended
PCB Pad Layout
Figure 1
Front View
RoHS
Compliant