240W Single Output Industrial DIN RAIL Power Supply DRP-240 series Features : Universal AC input / Full range Built in active PFC function Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 100KHz 3 years warranty SPECIFICATION MODEL OUTPUT DRP-240-24 DRP-240-48 DC VOLTAGE 24V 48V RATED CURRENT 10A 5A CURRENT RANGE 0 ~ 10A 0 ~ 5A RATED POWER 240W 240W RIPPLE & NOISE (max.) Note.2 80mVp-p 150mVp-p VOLTAGE ADJ. RANGE 48 ~ 53V 1.0% 24 ~ 28V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION 0.5% LOAD REGULATION 1.0% 24ms/230VAC HOLD UP TIME (Typ.) INPUT Note.5 85 ~ 264VAC 24ms/115VAC at full load 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz 0.96/230VAC 84% 0.99/115VAC at full load AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.8A/115VAC 1.4A/230VAC OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION 85% COLD START 27A/115VAC 45A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 54 ~ 60V 30 ~ 36V Protection type : Shut down o/p voltage, re-power on to recover 100 5 (TSW1)detect on heat sink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 289.9Khrs min. MIL-HDBK-217F (25 125.5*125.2*100mm (W*H*D) 1.2Kg; 12pcs/15.5Kg/1.29CUFT DIMENSION PACKING NOTE 800ms, 40ms/115VAC at full load POWER FACTOR (Typ.) EFFICIENCY (Typ.) LEAKAGE CURRENT OTHERS 1.0% 800ms, 40ms/230VAC SETUP, RISE TIME VOLTAGE RANGE 0.5% ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:DRP-240-SPEC 2011-06-17 DRP-240 240W Single Output Industrial DIN RAIL Power Supply Mechanical Specification Case No. 922A series Unit:mm 125.5 100 125.2 TB1 LED 3 2 1 TB2 4 3 2 1 Terminal Pin Number Assignment (TB1) +V ADJ. Pin No. 1 2 3 35 ADMISSIBLE DIN-RAIL: TS35/7.5 OR TS35/15 Assignment FG AC/N AC/L Terminal Pin Number Assignment (TB2) Pin No. 1,2 3,4 Assignment DC OUTPUT +V DC OUTPUT -V Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING FG O.L.P. +V -V CONSTANT CURRENT LIMITING & DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. O.T.P. Derating Curve Output derating VS input voltage 100 100 230VAC 90 80 80 70 110VAC LOAD (%) LOAD (%) 60 40 20 60 50 40 -10 0 10 20 30 40 50 55 60 AMBIENT TEMPERATURE ( ) 70 (VERTICAL) Vin: -- 230VAC 110VAC 85 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:DRP-240-SPEC 2011-06-17