2 of 10
RF1146
DS091023
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Absolute Maximum Ratings
Parameter Rating Unit
V
DD
, V1, V2 6.0 V
Maximum Input Power (DC to
2.5GHz, 2.5V Control)
31 dBm
Operating Temperature -30 to +85 °C
Storage Temperature -65 to +100 °C
Parameter Specification Unit Condition
Min. Typ. Max.
Operating Characteristics Active Mode:V
HIGH
>1.8V,V
LOW
<0.4V;
V
DD
=2.75V; Temp=25°C; P
IN
=26dBm unless
otherwise specified.
Insertion Loss
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT
0.35 0.50 dB 824MHz to 960MHz
0.35 0.60 dB 1574MHz to 1577MHz
0.45 0.65 dB 1850MHz to 1990MHz
0.55 0.70 2170MHz to 2500MHz
Isolation
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT
18 29 dB 824MHz to 960MHz
22 24 dB 1574MHz to 1577MHz
20 22 dB 1850MHz to 1990MHz
17 20 dB 2170MHz to 2500MHz
Return Loss
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT
19 dB 600MHz to 2500 MHz, All RF ports in Insertion
Loss state.
Harmonics
Second Harmonic (2f
0
)7086 dBcf=880MHz, P
IN
=26dBm
70 88 dBc f=1880MHz, P
IN
=26dBm
Third Harmonic (3f
0
)7081 dBcf=880MHz, P
IN
=26dBm
70 79 dBc f=1880MHz, P
IN
=26dBm
IIP2
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT (Cell)
102 106 dBm Tone 1: 824MHz @ 16dBm, Tone 2: 1693MHz
@ -20dBm, Receive Freq: 869MHz
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT (AWS)
104 108 dBm Tone 1: 1710MHz @ 16dBm, Tone 2:
3820MHz @ -20dBm, Receive Freq: 2110MHz
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT (PCS)
106 110 dBm Tone 1: 1850MHz @ 16dBm, Tone 2:
3780MHz @ -20dBm, Receive Freq: 1930MHz
Triple Beat Ration (TBR)
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT (Cell)
65 68 dBc VSWR=2:1; Temp=15°C, 25°C, 60°C; Jam-
mer Freq=881.5MHz
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT (PCS)
65 68 dBc VSWR=2:1; Temp=15°C, 25°C, 60°C; Jam-
mer Freq=1960MHz
0.1dB Compression (P0.1dB)
28 dBm f=900MHz
28 dBm f=1800MHz
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.