DC-DC CONVERTERS 10.8-15 W High Efficiency DC-DC Converters 1
2 YEAR WARRANTY
CXE15 Series
Single output
High efficiency topology, 87% typical at 5 V
Industry standard footprint
Wide operating temperature, up to and exceeding 70 ˚C
(natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote ON/OFF control
The CXE15 is a new high efficiency open frame isolated 15 Watt converter series
in an industry standard footprint. The first four models in the series feature an input
voltage range of 33 Vdc to 75 Vdc and are available in output voltages of 5 V,
3.3 V, 2.5 V and 1.8 V. The output voltage on each model is adjustable from 90%
to 110% of the nominal value. Typical efficiencies for the models are 87% for the 5
V, 86% for the 3.3 V, 85% for the 2.5 V and 83% for the 1.8 V version. The CXE15
series also has a remote ON/OFF capability with active high or active low logic.
Overcurrent and overvoltage protection features are included as standard. With full
international safety approval including EN60950 and cUL1950, the CXE15 reduces
compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
Radiated emissions
EN55022 (See Longform datasheet)
Level B
Immunity:
ESD air EN61000-4-2 8 kV, 15 kV
ESD contact EN61000-4-2 6 kV, 8 kV
Radiated field enclosure EN61000-4-3 10 V/m
Conducted (dc power) EN61000-4-6 10 V
Conducted (signal) EN61000-4-6 10 V (See Note 8)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Operational insulation Input/output 1500 Vdc
Switching frequency Fixed 265 kHz typ.
Approvals and UL/cUL1950, EN60950
standards TÜV Rheinland
(See Note 5)
Material flammability UL94V-0
Weight 12 g (0.42 oz)
MTBF MIL-HDBK-217F 3,628,000 hours
Representative model: 48S05J @ 48 Vin, 40 °C,
100% load ground benign
BELLCORE 332 >1,500,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40 °C to +65 °C
(See Note 9) temp. (3.3 V and 5 V)
Operating ambient -40 °C to +70 °C
temp. (1.8 V and 2.5 V)
Non-operating -40 °C to +120 °C
(All models)
OUTPUT SPECIFICATIONS
Voltage adjustability 90% to 110%
Total error band (See Note 11) ±3.5% max.
Line regulation 1.8 V and 2.5 V models 0.5% max.
Low line to high line 3.3 V and S05 models 0.1% max.
Load regulation 1.8 V model 2.0% max.
Full load to min. load 2.5 V model 1.5% max.
3.3 V and S05 models 0.5% max.
Minimum load 0%
Overshoot 1.8 V and 2.5 V models 3.5% max.
3.3 V and S05 models None
Undershoot None
Ripple and noise 1.8 V and 2.5 V models 40 mV pk-pk
(See Note 1) 14 mV rms
5 Hz to 20 MHz 3.3 V and S05 models 70 mV pk-p
20 mV rms
Transient response 1.8 V and 2.5 V models 150 mV
(See Note 2) 3.3 V and S05 models 100 mV
typ. deviation 400 µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 33-75 Vdc
Input current No load 35 mA max.
Remote OFF 25 mA max.
Input current (max.) (See Note 4) 0.55 A max. @ Io max.
and Vin = 33-75 Vdc
Input reflected ripple (See Note 6) 5 mA (pk-pk) typ.
Active high remote ON/OFF (See Note 10)
Logic compatibility Open collector ref to -input
ON Open circuit or >2 Vdc
OFF <1.2 Vdc
Undervoltage lockout Power up 33 V (typ.)
Power down 30 V (typ.)
Start-up time Power up 1.5 ms (typ.)
(See Note 7) Remote ON/OFF 2.5 ms (typ.)
SPECIFICATIONS
File Name: cxe15s_obs.pdf Rev: 01 Mar 2006
TÜV
For the most current data and application support visit w w w.artesyn.com/powerg roup/produ cts.htm
NNootteess
1Measured as per recommended set-up. See Application Note 116 for
details.
2di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3The CXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
4Recommended input fusing is a 2 A HRC 200 V rated fuse.
5This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6Measured with external filter. See Application Note 116 for details.
7Start-up into resistive load.
8Signal line assumed < 3 m in length.
9Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow. See
Application Note 116 for details.
10 Remote ON/OFF (pin 3) and Trim (pin 5) are currently available individually
or together by special order only. Manufacturing lead times may apply. The
base model includes pins 1, 2, 4, and 6. Use the suffix ‘–R’ for pin 3 with
negative logic, ‘-S’ for pin 3 with positive logic, and ‘-T’ for the Trim pin.
11 This parameter is calculated at worst case line, load, temperature and initial
settings.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit Continuous
Overvoltage Non-latching clamp
TELECOM SPECIFICATION
Central office interface A ETS300-132-2, input voltage
and current requirements
CXE15 Series
Single output
DC-DC CONVERTERS 10.8-15 W High Efficiency DC-DC Converters 2
File Name: cxe15s_obs.pdf Rev: 01 Mar 2006
OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODEL
POWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (10)
(MAX.) (MIN.) (MAX.)
10.8 W 33-75 Vdc 2.3 Vdc 1.8 V 0 A 6 A 83% 0.3% 2.0% CXE15-48S1V8
15 W 33-75 Vdc 3.2 Vdc 2.5 V 0 A 6 A 85% 0.3% 1.5% CXE15-48S2V5
15 W 33-75 Vdc 4 Vdc 3.3 V 0 A 4.5 A 86% 0.1% 0.5% CXE15-48S3V3
Datasheet © Artesyn Technologies
®
2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit w w w.artesyn.com/powerg roup/produ cts.htm
CXE15 Series
Single output
DC-DC CONVERTERS 10.8-15 W High Efficiency DC-DC Converters 3
Please consult our website for the following items: 4 Application Note 4 Longform Data Sheet www.artesyn.com
File Name: cxe15s_obs.pdf Rev: 01 Mar 2006
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TÜV Rheinland. Certificate No. R2074133
File No. 10401-3336-0916
1.000 (25.40)
TOP VIEW
SIDE VIEW
BOTTOM VIEW
2.000 (50.80)
0.600 (15.24) 0.600 (15.24)
0.800 (20.32)
0.200 (5.08)
0.300 (7.62)
0.10
(2.54)
0.400 (10.16)
0.800 (20.32)
0.120 (3.05)
0.100
(2.54) 0.800 (20.32) Case Outline
0.400 (10.16)
0.400 (10.16)
0.040 (1.016)
0.200
(5.08)
0.200 (5.08)
.200(5.08) .560 (14.22)
.060 (1.52)
Standoff (4 places) Plated Through Hole
0.052-0.06 (1.321-1.40) typical
Recommended Hole Pattern
0.015 (0.38)
0.350 (8.89)
0.400 (10.16)
0.600 (15.24)
1
2
4
5
63
0.040 (1.02)
4
5
63
1
2
Dimensions in Inches [mm]
PIN CONNECTIONS
PIN NUMBER FEATURE
1Vin -
2 Vin +
3 On/Off (See Note 10)
4 Vout +
5 Trim (See Note 10)
6 Vout -
TÜV