82 Compensated
82C www.meas-spec.com August 2011
2/4
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25° C (unless otherwise specifi ed )
PARAMETERS 001PSI 005PSI ≥015PSI UNITS NOTES
MIN TYP MAX MIN TYP MAX MIN TYP MAX
Span 50 100 150 50 100 150 75 100 150 mV 1
Zero Pressure Output -2 0 2 -2 0 2 -1 0 1 mV
Pressure Non Linearit y -0.3 0.3 -0.2 +0.2 -0.1 0.1 %Span 2
Pressure Hysteresis -0.10 ±0.02 0.10 -0.10 ±0.02 0.10 -0.05 ±0.02 0.05 %Span
Repeatability ±0.02 ±0.02 ±0.02 %Span
Input Resistanc e 2.5 5.0 6.5 2.5 5.0 6.5 3.8 5.8 KΩ
Output Resistance 4.0 7.0 4.0 7.0 4.0 6.0 KΩ
Thermal Hysteresis – Span -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 -0.25 ±0.05 +0.25 %Span 3
Thermal Hysteresis – Offset -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 -0.25 ±0.05 +0.25 %Span 3
Temperature Error – Span -1.0 1.0 -1.0 1.0 -0.75 0.75 %Span 3
Temperature Error – Offset -1.0 1.0 -1.0 1.0 -0.5 0.5 %Span 3, 9
Long Term Stability – Span ±0.10 ±0.10 ±0.10 %Span 4
Long Term Stability – Offset ±0.25 ±0.25 ±0.10 %Span 4
Supply Current 0.5 1.5 2.0 0.5 1.5 2.0 0.5 1.5 2.0 mA
Insulation Resist ance (50Vdc) 50 50 50 MΩ 5
Output Noise (10Hz to 1KHz) 1 1 1 uV p-p
Response Time (10% to 90%) 0.1 0.1 0.1 ms
Pressure Overload 10x 3x 3x Rated 6
Pressure Burst 12x 4x 4x Rated
Operating Temperature -20 +70 -20 +70 -40 +125 ºC
Compensated Temperature 0 +50 0 +70 -20 +85 °C
Storage Temperature -50 +125 -50 +125 -50 +125 ºC 7
Media – Pressure Port Liqui ds and Gases compatible with 316L Stainless Steel and Buna-N 8
Media – Reference Port Compatible with Sil icon, P yrex, Gold, Fluoros i l icone RTV and 316L Stainless Steel
Notes
1. Ratiometric to supply current.
2. Best fit straight l i ne.
3. Maximum t em perature error within the compensated temperature range with respect to 25°C.
4. Long term st ability over a one year period with constant current and temperature.
5. Minim um resistance between case and pins.
6. 10 psi maximum for 1 psi devices.
7. Maximum tem perature range for product with standard cable and connector is -20°C to +105°C.
8. Gage units not recommended for high vacuum applic ations. For high vacuum applications consult factory.
9. Temperature Error – Offset for 15psi is -0.75 to 0.75 and >15psi is -0.5 to 0.5.