273
www.meder.com
MEDER electronic MK21 Series
Reed Sensors with Mounting
Holes for Screw Fastening
CONTACT DATA
All Data at 20° C Switch Model →
Contact Form →
Switch 85
Form A
Switch 90
Form B/C, potted
Contact Ratings Conditions Min. Typ. Max. Min. Typ. Max. Unit
Switching Power
Any DC combination of V & A
not to exceed their individual
max.‘s
100 20 W
Switching Voltage DC or peak AC 400 175 V
Switching Current DC or peak AC 1.0 0.5 A
Carry Current DC or peak AC 2.5 1.0 A
Static Contact Resistance w/ 0.5 V & 10 mA 150 150 mΩ
Dynamic Contact Resistance Measured w/ 0.5 V & 50 mA ,
1.5 ms after closure 200 250 mΩ
Insulation Resistance across
Contact 100 volts applied 1010 109Ω
Breakdown Voltage across
Contact
Voltage applied for 60 sec.
min. 4000 200 VDC
Operate Time incl. Bounce Measured w/ 100 % overdrive 1.0 0.7 ms
Release Time Measured w/ no coil
suppression 0.1 1.5 ms
Capacitance at 10 kHz cross contact 0.2 1.0 pF
Contact Operation **
Must Operate Condition Steady state eld 20 60 15 40 AT
Must Release Condition Steady state eld 12 54 AT
Environmental Data
Shock Resistance 1/2 sinus wave duration 11 ms 50 50 g
Vibration Resistance From 10 - 2000 Hz 20 20 g
Ambient Temperature M 10°C/ minute max. allowable -20 85 -20 85 oC
Ambient Temperature P 10°C/ minute max. allowable -35 85 -35 85 oC
Stock Temperature 10°C/ minute max. allowable 260 260 oC
Soldering Temperature 5 sec. 260 260 oC
Please note: The indicated electrical data are maximum values and can vary downwards when using a more
sensitive switch.
* Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodied Reed Switches described in our Reed Switch section. Consult
factory if more detail is required.