Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para -
me ters, test conditions and
processing information only
to be used together with the
'Definitions' section in the
cat -
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays SCHRACK
2
Power PCB Relay RT1 (Continued)
Coil versions, DC-coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ohm mW
005 5 3.5 0.5 62+10% 403
006 6 4.2 0.6 90+10% 400
009 9 6.3 0.9 200+10% 400
012 12 8.4 1.2 360+10% 400
024 24 16.8 2.4 1440+10% 400
048 48 33.6 4.8 5520+10% 417
060 60 42.0 6.0 8570+12% 420
110 110 77.0 11.0 28800+12% 420
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Coil versions, AC-coil 50Hz
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
50 Hz 50 Hz 50 Hz
VAC VAC VAC Ohm VA
524 24 18.0 3.6 350+10% 0.76
615 115 86.3 17.3 8100+15% 0.76
620 120 90.0 18.0 8800+15% 0.75
700 200 150.0 30.0 24350+15% 0.76
730 230 172.5 34.5 32500+15% 0.74
All figures are given for coil without preenergization, at ambient temperature +23°C
Insulation
Dielectric strength coil-contact circuit 5000 Vrms
open contact circuit 1000 Vrms
Clearance / creepage coil-contact circuit W10 / 10 mm
Material group of insulation parts IIIa
Tracking index of relay base PTI 250 V
Insulation to IEC 61810-1
Type of insulation coil-contact circuit reinforced
open contact circuit micro disconnection
Rated insulation voltage 250 V
Pollution degree 12 A version 3 3
16 A version 3 2
Rated voltage system 240 V 230 / 400 V
Overvoltage category III
Other data
Mechanical endurance DC coil > 30 x 106cycles
AC coil > 10 x 106cycles
Material
RoHS - Directive 2002/95/EC compliant as per product date code 0413
Resistance to heat and fire, WG version according EN60335-1, par.30
Environment
Ambient temperature range DC coil -40...+85°C
AC coil -40...+70°C
Vibration resistance (function), NO / NC cont. 20 / 5 g, 30 ... 500 Hz
Shock resistance (destruction) 100 g
Category of protection RTII - flux proof, RTIII - wash tight
Processing
Mounting pcb or on socket
Mounting position any
Mounting distance DC / AC coils W 0 / W 2.5 mm
Resistance to soldering heat flux-proof version 270°C / 10 s
wash-tight version 260°C / 5 s
Relay weight 14 g
Packaging unit 20 / 500 pcs
Accessories
For details see datasheet Accessories Power Relay RT