Data Sheet W3011
September 1999 1 GHz Quadrature Modulator
Lucent Technologies Inc. 5
Electrical Characteristics (continued)
Table 5. ac Specifications
Conditions unless otherwise noted: 2.7 ≤ VCC ≤ 3.3 Vdc; TA = 25 °C ± 3 °C; RL = 50 Ω, VAPC = 2.7 Vdc;
fRF = 900 MHz, fLOL = 130 MHz, fLOH = 1030 MHz, –15 dBm < PLOL, PLOH < –5 dBm;
I – I= 0.4 cos(2πt Ÿ 80 kHz), Q – Q = 0.4 cos(2πt Ÿ 80 kHz – π/2), Vbias of I, I, Q, and Q= 1.22 Vdc.
Parameter Min Typ Max Unit
I & Q
I & Q Signal Path 0.5 dB Bandwidth —5—MHz
I & Q Input Resistance —200 —kΩ
I & Q Input Capacitance to Ground —5—pF
I & Q Input Differential Signal for Max Output —0.8 —Vp-p
Offset Mixer
LOL Input Impedance —50 —Ω
LOH Input Impedance —50 —Ω
LO Input Impedance (pins LC1, LC2) —480//1 —Ω//pF
LOL Input IP3 —10 —dBm
Modulation Accuracy (POUT = –1 dBm)
Carrier Suppression (POUT = –1 dBm) —–35 –28 dBUSB
Carrier Suppression (entire usable APC range) — — –26 dBUSB
Origin Offset (DQPSK inputs, all usable APC levels) — — –23 dBc
Error Vector Magnitude (See Explanation of Error Vector Magnitude
(EVM) Testing section.) —2.5 5%
Lower Sideband (LSB) Suppression (See Figure 3.) —–43 –34 dBUSB
RF Output
Output Power (0.8 Vp-p differential or single-ended 80 kHz sine-wave
inputs to I and Q, with 90° between I and Q) –1 3 —dBm
Adjacent Channel Suppression (0.282 Vrms differential I and Q inputs,
π/4 – DQPSK modulation, random data):
Per PDC (RCR STD-27):
±50 kHz, All Usable APC Levels
±100 kHz, All Usable APC Levels
±100 kHz, Max RF Output (APC > 2.2)
Per IS-136/IS-137 800 MHz Digital Mode:
±30 kHz, All Usable APC Levels
±60 kHz, All Usable APC Levels
—
—
—
—
—
–65
—
–75
–45
–60
–55
–62
–65
–36
–50
dBc
dBc
dBc
dBc
dBc
Noise Floor Suppression, FC ± >100 kHz —–120 –112 dBc/Hz
APC (Automatic Power Control) Function
Range of Usable Output Power Control for Japan PDC (RCR STD-27),
from Max Power at APC = 2.7 V to Minimum APC Voltage Where
Requirements for ACP and Carrier Suppression Are Still Met Using
π/4 – DQPSK/α = 0.5 Modulation at 0.282 Vrms Differential I and Q
Inputs:
Offset Mixer Not Used
Offset Mixer Used 29
39 40
45 —
—dB
dB
Output Power Variation Due to Temperature, within Usable Control Range —4 6 dB
RF Power Change Time (after APC change) — — 2µs
APC Voltage for Max Output Power —2.2 —Vdc
APC Voltage for Min Output Power —0.8 —Vdc