Product datasheet XU2S18PP340D Characteristics security light curtain XU2-S - detection of body 750..1200 mm - 12..24 V Range of product Preventa Safety detection Product or component type Safety thru-beam pair photo-electric sensors Device short name XU2S Output type 1 safety outputs OSSD PNP [Sn] nominal sensing distance 8m Complementary Detection system Transmitter-receiver system [Us] rated supply voltage 12...24 V DC (10...30 V) reverse polarity protection Current consumption <= 35 mA no-load Voltage drop <= 1.5 V closed state Switching capacity in mA <= 100 mA (overload and short-circuit protection) Switching frequency 500 Hz maximum Electrical connection 1 male connector M12 4 pins Line of sight type Along case axis Delay response <= 1 ms Delay recovery <= 1 ms Function available Built-in muting function Light or dark programmable switching Marking CE Material Case: nickel plated brass Lenses: PMMA (polymethyl methacrylate) Product weight 0.155 kg Environment Standards EN/IEC 60825-1 EN/IEC 61496-1 EN/IEC 61496-2 Safety level Type 2 conforming to IEC 61496-1-2 Can reach PL = c conforming to EN/ISO 13849-1 (associated with module XPSCM correctly wired) Can reach category 2 conforming to EN/ISO 13849-1 (associated with module XPSCM correctly wired) Ambient air temperature for operation -25...55 C Safety reliability data PFH = 4.6E-7 1/h conforming to IEC 61508 PFH = 5.5E-7 1/h conforming to IEC 61508 (with muting function) Ambient air temperature for storage -40...70 C IP degree of protection IP67 conforming to EN/IEC 60529 Shock resistance 30 gn (3 axes : 3 times) conforming to EN/IEC 60068-2-27 Vibration resistance 7 gn (f = 10...55 Hz) conforming to EN/IEC 60068-2-6 Offer Sustainability Sustainable offer status Green Premium product RoHS Compliant - since 1005 - Schneider Electric declaration of conformity 1/2 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main REACh Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available 2/2 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schneider Electric: XU2S18PP340D