CY22381 CY223811 Three-PLL General Purpose FLASH Programmable Clock Generator Features Three integrated phase-locked loops Ultra-wide divide counters (eight-bit Q, eleven-bit P, and seven-bit post divide) Improved linear crystal load capacitors Flash programmability Field programmability Low-jitter, high-accuracy outputs Power-management options (Shutdown, OE, Suspend) Configurable crystal drive strength Frequency select option through external LVTTL Input 3.3V operation 8-pin SOIC package (CY22381) 8-pin SOIC package with NiPdAu lead finish (CY223811) CyClocks RTTM support Benefits Generates up to three unique frequencies on three outputs up to 200 MHz from an external source. Functional upgrade for current CY2081 family. Improves frequency accuracy over temperature, age, process, and initial offset Non-volatile programming enables easy customization, ultra-fast turnaround, performance tweaking, design timing margin testing, inventory control, lower part count, and more secure product supply. Can also be programmed multiple times which reduces programming errors and provides an easy upgrade path for existing designs In-house programming of samples and prototype quantities is available using the CY3672 FTG development Kit. Production quantities are available through Cypress's value-added distribution partners or by using third party programmers from BP Microsystems, HiLo Systems, and others. Performance suitable for high-end multimedia, communications, industrial, A/D converters, and consumer applications Supports numerous low-power application schemes and reduces EMI by allowing unused outputs to be turned off Adjust crystal drive strength for compatibility with virtually all crystals External frequency select option for PLL1, CLKA, and CLKB Industry standard supply voltage Industry standard packaging saves on board space Easy-to-use software support for design entry Allows for 0 ppm frequency generation and frequency conversion under the most demanding applications Logic Block Diagram XTALIN XTALOUT OSC. PLL1 11-BIT P 8-BIT Q CONFIGURATION FLASH PLL2 11-BIT P 8-BIT Q SHUTDOWN/OE FS/SUSPEND 4x3 Crosspoint Switch Divider 7-BIT CLKC Divider 7-BIT CLKB Divider 7-BIT CLKA PLL3 11-BIT P 8-BIT Q Cypress Semiconductor Corporation Document #: 38-07012 Rev. *F * 198 Champion Court * San Jose, CA 95134-1709 * 408-943-2600 Revised December 11, 2008 [+] Feedback CY22381 CY223811 Pinouts Figure 1. CY22381, CY223811- 8-pin SOIC CLKC GND XTALIN XTALOUT 1 2 3 4 FS/SUSPEND/OE/SHUTDOWN VDD CLKA CLKB 8 7 6 5 Pin Definitions Name Pin Number Description CLKC 1 Configurable clock output C GND 2 Ground XTALIN 3 Reference crystal input or external reference clock input XTALOUT 4 Reference crystal feedback (float if XTALIN is driven by external reference clock) CLKB 5 Configurable clock output B CLKA 6 Configurable clock output A VDD 7 Power supply FS/SUSPEND/ OE/SHUTDOWN 8 General Purpose Input. Can be Frequency Control, Suspend mode control, Output Enable, or full-chip shutdown. Operation The CY22381 is an upgrade to the existing CY2081. The new device has a wider frequency range, greater flexibility, improved performance, and incorporates many features that reduce PLL sensitivity to external system issues. The device has three PLLs that allow each output to operate at an independent frequencies. These three PLLs are completely programmable. of PLL1, the output divider of CLKB, and the output divider of CLKA. Any divider change as a result of switching the FS input is guaranteed to be glitch free. The general-purpose input can simultaneously control the Suspend feature, turning off a set of PLLs and outputs determined during programming. When programmed as an Output Enable (OE) the input forces all outputs to be placed in a three-state condition when LOW. The CY223811 is the CY22381 with NiPdAu lead finish. When programmed as a Shutdown, the input forces a full chip shutdown mode when LOW. Configurable PLLs Crystal Input PLL1 generates a frequency that is equal to the reference divided by an eight-bit divider (Q) and multiplied by an 11-bit divider in the PLL feedback loop (P). The output of PLL1 is sent to the crosspoint switch. The frequency of PLL1 can optionally be changed by using the external CMOS general purpose input. See the following section on "General-Purpose Input" for more detail. The input crystal oscillator is an important feature of this device because of its flexibility and performance features. PLL2 generates a frequency that is equal to the reference divided by an eight-bit divider (Q) and multiplied by an 11-bit divider in the PLL feedback loop (P). The output of PLL2 is sent to the crosspoint switch. PLL3 generates a frequency that is equal to the reference divided by an eight-bit divider (Q) and multiplied by an 11-bit divider in the PLL feedback loop (P). The output of PLL3 is sent to the cross-point switch. General-Purpose Input The CY22381 features an output control pin (pin 8) that can be programmed to control one of four features. When programmed as a Frequency Select (FS), the input can select between two arbitrarily programmed frequency settings. The Frequency Select can change the following; the frequency Document #: 38-07012 Rev. *F The oscillator inverter has programmable drive strength. This allows for maximum compatibility with crystals from various manufacturers, processes, performances, and qualities. The input load capacitors are placed on-die to reduce external component cost. These capacitors are true parallel-plate capacitors for ultra-linear performance. These were chosen to reduce the frequency shift that occurs when non-linear load capacitance interacts with load, bias, supply, and temperature changes. Non-linear (FET gate) crystal load capacitors must not be used for MPEG, POTS dial tone, communications, or other applications that are sensitive to absolute frequency requirements The value of the load capacitors is determined by six bits in a programmable register. The load capacitance can be set with a resolution of 0.375pF for a total crystal load range of 6pF to 30pF. For driven clock inputs the input load capacitors may be completely bypassed. This enables the clock chip to accept driven frequency inputs up to 166 MHz. If the application requires a driven input, then XTALOUT must be left floating. Page 2 of 9 [+] Feedback CY22381 CY223811 Output Configuration Under normal operation there are four internal frequency sources that may be routed through a programmable crosspoint switch to any of the three outputs through programmable seven-bit output dividers. The four sources are: reference, PLL1, PLL2, and PLL3. The following is a description of each output. CLKA's output originates from the crosspoint switch and goes through a programmable seven-bit post divider. The seven-bit post divider derives its value from one of two programmable registers controlled by FS. CLKB's output originates from the crosspoint switch and goes through a programmable seven-bit post divider. The seven-bit post divider derives its value from one of two programmable registers controlled by FS. CLKC's output originates from the crosspoint switch and goes through a programmable seven-bit post divider. The seven-bit post divider derives its value from one programmable register. The Clock outputs have been designed to drive a single point load with a total lumped load capacitance of 15pF. While driving multiple loads is possible with the proper termination, it is generally not recommended. Power-Saving Features When configured as OE, the general-purpose input three-states all outputs when pulled LOW. When configured as Shutdown, a LOW on this pin three-states all outputs and shuts off the PLLs, counters, the reference oscillator, and all other active components. The resulting current on the VDD pins is less than Document #: 38-07012 Rev. *F 5 A (typical). After leaving shutdown mode, the PLLs has to relock. When configured as SUSPEND, the general-purpose input can be configured to shut down a customizable set of outputs and/or PLLs, when LOW. All PLLs and any of the outputs can be shut off in nearly any combination. The only limitation is that if a PLL is shut off, all outputs derived from it must also be shut off. Suspending a PLL shuts off all associated logic, while suspending an output forces a three-state condition. Improving Jitter Jitter Optimization Control is useful in mitigating problems related to similar clocks switching at the same moment and causing excess jitter. If one PLL is driving more than one output, the negative phase of the PLL can be selected for one of the outputs. This prevents the output edges from aligning, allowing superior jitter performance. CyClocks RT Software CyClocks RT is our second-generation application that allows users to configure this device. The easy-to-use interface offers complete control of the many features of this family including input frequency, PLL and output frequencies, and different functional options. Data sheet frequency range limitations are checked and performance tuning is automatically applied. You can download a free copy of CyClocks RT on Cypress's web site at http://www.cypress.com. Page 3 of 9 [+] Feedback CY22381 CY223811 Maximum Ratings Exceeding maximum ratings may shorten the useful life of the device. User guidelines are not tested. Data Retention at Tj = 125C ................................> 10 years Supply Voltage................................................-0.5V to +7.0V Package Power Dissipation...................................... 250 mW DC Input Voltage ..............................-0.5V to + (VDD + 0.5V) Static Discharge Voltage Storage Temperature .................................. -65C to +125C (per MIL-STD-883, Method 3015) ........................... 2000V Junction Temperature .................................................. 125C Latch up (per JEDEC 17) .................................... 200 mA Maximum Programming Cycles........................................100 Operating Conditions Parameter Description VDD Supply Voltage TA Commercial Operating Temperature, Ambient Industrial Operating Temperature, Ambient CLOAD_OUT Max. Load Capacitance fREF tPU Min Typ Max Unit 3.135 3.3 3.465 V 0 - +70 C -40 - +85 C - - 15 pF External Reference Crystal 8 - 30 MHz External Reference Clock[2], Commercial 1 - 166 MHz External Reference Clock[2], Industrial 1 - 150 MHz 0.05 - 500 ms Power up time for all VDD's to reach minimum specified voltage (power ramps must be monotonic) Electrical Characteristics Parameter IOH IOL Min Typ Max Unit Output High Current[3] VOH = VDD - 0.5, VDD = 3.3 V 12 24 - mA Output Low Current[3] VOL = 0.5V, VDD = 3.3 V 12 24 - mA Crystal Load Capacitance[3] CXTAL_MAX Crystal Load Capacitance[3] CIN Input Pin Capacitance[3] CXTAL_MIN Conditions[1] Description Capload at minimum setting - 6 - pF Capload at maximum setting - 30 - pF Except crystal pins - 7 - pF VIH HIGH-level Input Voltage CMOS levels,% of VDD 70% - - VDD VIL LOW-level Input Voltage CMOS levels,% of VDD - - 30% VDD IIH Input HIGH Current VIN = VDD - 0.3 V - <1 10 A IIL Input LOW Current VIN = +0.3 V - <1 10 A IOZ Output Leakage Current Three-state outputs - - 10 A IDD Total Power Supply Current 3.3 V Power Supply; 3 outputs at 50 MHz - 35 - mA 3.3 V Power Supply; 3 outputs at 166 MHz - 70 - mA IDDS Total Power Supply Current in Shutdown active Shutdown Mode - 5 20 A Notes 1. Unless otherwise noted, Electrical and Switching Characteristics are guaranteed across these operating conditions. 2. External input reference clock must have a duty cycle between 40% and 60%, measured at VDD/2. 3. Guaranteed by design, not 100% tested. Document #: 38-07012 Rev. *F Page 4 of 9 [+] Feedback CY22381 CY223811 Switching Characteristics Parameter Name Description 1/t1 Output Frequency[3, 4] t2 Output Duty Cycle[3, 5] Clock output limit, Commercial Clock output limit, Industrial Min Typ. Max Unit - - 200 MHz MHz - - 166 Duty cycle for outputs, defined as t2 / t1, Fout < 100 MHz, divider >= 2, measured at VDD/2 45% 50% 55% Duty cycle for outputs, defined as t2 / t1, Fout > 100 MHz or divider = 1, measured at VDD/2 40% 50% 60% t3 Rising Edge Slew Rate[3] Output clock rise time, 20% to 80% of VDD 0.75 1.4 - V/ns t4 Rate[3] Output clock fall time, 20% to 80% of VDD 0.75 1.4 - V/ns Time for output to enter or leave three-state mode after SHUTDOWN/OE switches - 150 300 ns Falling Edge Slew Timing[3] t5 Output Three-state t6 Clock Jitter[3, 6] Peak-to-peak period jitter, CLK outputs measured at VDD/2 - 200 - ps t7 Lock Time[3] PLL Lock Time from Power up - 1.0 3 ms Switching Waveforms Figure 2. All Outputs, Duty Cycle and Rise and Fall Time t1 t2 OUTPUT t3 t4 Figure 3. Output Three-State Timing OE t5 t5 ALL THREE-STATE OUTPUTS Figure 4. CLK Output Jitter t6 CLK OUTPUT Notes 4. Guaranteed to meet 20% - 80% output thresholds and duty cycle specifications. 5. Reference Output duty cycle depends on XTALIN duty cycle. 6. Jitter varies significantly with configuration. Reference Output jitter depends on XTALIN jitter and edge rate. Document #: 38-07012 Rev. *F Page 5 of 9 [+] Feedback CY22381 CY223811 Switching Waveforms (continued) Figure 5. Frequency Change SELECT OLD SELECT Fold NEW SELECT STABLE t7 Fnew OUTPUT Test Circuit VDD 0.1 mF OUTPUTS CLKout CLOAD GND Document #: 38-07012 Rev. *F Page 6 of 9 [+] Feedback CY22381 CY223811 Ordering Information Ordering Code [8] Package Type Operating Range Operating Voltage 8-SOIC Commercial (TA=0C to 70C) 3.3V 8-SOIC - Tape and Reel Commercial (TA=0C to 70C) 3.3V 8-SOIC - Tape and Reel Industrial (TA=-40C to 85C) 3.3V 8-SOIC with NiPdAu lead frame Industrial (TA=-40C to 85C) 3.3V CY22381FSZC 8-SOIC Commercial (TA=0C to 70C) 3.3V CY22381FXC[9] 8-SOIC Commercial (TA=0C to 70C) 3.3V CY22381FXCT 8-SOIC - Tape and Reel Commercial (TA=0C to 70C) 3.3V CY22381FXI 8-SOIC Industrial (TA=-40C to 85C) 3.3V CY22381FC [8] CY22381FCT CY22381SI-xxxT [7, 8] CY3672-USB FTG Programmer CY3699 CY22381F Adapter for CY3672-USB Pb-Free CY223811FXI [9] CY22381FXIT 8-SOIC - Tape and Reel Industrial (TA=-40C to 85C) 3.3V CY22381SXC-xxx[7] 8-SOIC Commercial (TA=0C to 70C) 3.3V CY22381SXC-xxxT[7] 8-SOIC - Tape and Reel Commercial (TA=0C to 70C) 3.3V CY22381SXI-xxx[7] 8-SOIC Industrial (TA=-40C to 85C) 3.3V CY22381SXI-xxxT[7] 8-SOIC - Tape and Reel Industrial (TA=-40C to 85C) 3.3V Notes 7. The CY22381SI-xxx, CY22381SXC-xxx and CY22381SXI-xxx are factory programmed configurations. Factory programming is available for high-volume design opportunities of 100Ku/year or more in production. For more details, contact your local Cypress FAE or Cypress Sales Representative. 8. Not recommended for new designs. 9. The CY22381FSZC and CY22381FXC are identical. For new designs, use CY22381FXC. Document #: 38-07012 Rev. *F Page 7 of 9 [+] Feedback CY22381 CY223811 Package Drawing and Dimensions 8 Lead (150 Mil) SOIC - S08 Figure 6. 8-Pin (150-Mil) SOIC S8 PIN 1 ID 4 1 1. DIMENSIONS IN INCHES[MM] MIN. MAX. 2. PIN 1 ID IS OPTIONAL, ROUND ON SINGLE LEADFRAME RECTANGULAR ON MATRIX LEADFRAME 0.150[3.810] 0.157[3.987] 3. REFERENCE JEDEC MS-012 0.230[5.842] 0.244[6.197] 4. PACKAGE WEIGHT 0.07gms PART # S08.15 STANDARD PKG. 5 SZ08.15 LEAD FREE PKG. 8 0.189[4.800] 0.196[4.978] 0.010[0.254] 0.016[0.406] SEATING PLANE X 45 0.061[1.549] 0.068[1.727] 0.004[0.102] 0.050[1.270] BSC 0.004[0.102] 0.0098[0.249] 0~8 0.016[0.406] 0.035[0.889] 0.0075[0.190] 0.0098[0.249] 0.0138[0.350] 0.0192[0.487] 51-85066-*C Document #: 38-07012 Rev. *F Page 8 of 9 [+] Feedback CY22381 CY223811 Document History Page Document Title: CY22381, CY223811 Three-PLL General Purpose Flash Programmable Clock Generator Document Number: 38-07012 REV. ECN Orig. of Change Submission Date ** 106737 TLG 07/03/01 New data sheet *A 108514 JWK 08/23/01 Updated based on characterization results. Removed "Preliminary" heading Removed soldering temperature rating. Split crystal load into two typical specs representing digital settings range. Changed t5 max to 300 ns Changed t6 typical to 200 ps. Changed t7 typical to 1.0 ms *B 110053 CKN 12/10/01 Changed from preliminary to final *C 121863 RBI 12/14/02 Added power up requirements to Operating Conditions information Description of Change *D 279431 RGL See ECN Added lead-free devices *E 2584052 AESA 10/10/08 Updated template. Added Note 8 and 9. Added part number CY22381FC, CY22381FCT, CY3672-USB, CY3699, CY22381FSZC in ordering information table. Removed part number CY22381FI, CY22381FIT, CY22381SC-xxx, CY22381SC-xxxT, CY22381SI-xxx, and CY22381SI-xxxT in Ordering Information table. Added CY223811FXI (NiPdAu lead finish). Changed Lead-Free to Pb-Free. *F 2620588 KVM/AESA 12/11/08 Add CY223811 to the document title Distinguish between CY22381 and CY223811 in page 1 Features section Add part number CY22381SI-xxxT in Ordering Information table. Sales, Solutions, and Legal Information Worldwide Sales and Design Support Cypress maintains a worldwide network of offices, solution centers, manufacturer's representatives, and distributors. To find the office closest to you, visit us at cypress.com/sales. Products PSoC Clocks & Buffers PSoC Solutions psoc.cypress.com clocks.cypress.com General Low Power/Low Voltage psoc.cypress.com/solutions psoc.cypress.com/low-power Wireless wireless.cypress.com Precision Analog Memories memory.cypress.com LCD Drive psoc.cypress.com/lcd-drive image.cypress.com CAN 2.0b psoc.cypress.com/can USB psoc.cypress.com/usb Image Sensors psoc.cypress.com/precision-analog (c) Cypress Semiconductor Corporation, 2001-2008. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor intended to be used for medical, life support, life saving, critical control or safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges. Any Source Code (software and/or firmware) is owned by Cypress Semiconductor Corporation (Cypress) and is protected by and subject to worldwide patent protection (United States and foreign), United States copyright laws and international treaty provisions. Cypress hereby grants to licensee a personal, non-exclusive, non-transferable license to copy, use, modify, create derivative works of, and compile the Cypress Source Code and derivative works for the sole purpose of creating custom software and or firmware in support of licensee product to be used only in conjunction with a Cypress integrated circuit as specified in the applicable agreement. Any reproduction, modification, translation, compilation, or representation of this Source Code except as specified above is prohibited without the express written permission of Cypress. Disclaimer: CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Cypress reserves the right to make changes without further notice to the materials described herein. Cypress does not assume any liability arising out of the application or use of any product or circuit described herein. Cypress does not authorize its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress' product in a life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges. Use may be limited by and subject to the applicable Cypress software license agreement. Document #: 38-07012 Rev. *F Revised December 11, 2008 Page 9 of 9 CYClocks RT is a trademark of Cypress Semiconductor Corporation. All products and company names mentioned in this document may be the trademarks of their respective holders. [+] Feedback