R
o
H
S
www.littelfuse.com 3 - 2 © 2006 Littelfuse • Telecom Design Guide
SIDACtor® Device
DO-214AA SIDACtor solid state protection devices protect telecommunications equipment
such as modems, line cards, and CPE (telephones, answering machines, and fax
machines).
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For individual “SA”, “SB”, and “SC” surge ratings, see table below.
General Notes:
All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
* Current waveform in µs
** Voltage waveform in µs
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
P0080S_L 625458002.250
P0220S_L 15 32 4 5 800 2.2 50
P0300S_L 25 40 4 5 800 2.2 50
P0640S_L 58 77 4 5 800 2.2 150
P0720S_L 65 88 4 5 800 2.2 150
P0900S_L 75 98 4 5 800 2.2 150
P1100S_L 90 130 4 5 800 2.2 150
P1300S_L 120 160 4 5 800 2.2 150
P1500S_L 140 180 4 5 800 2.2 150
P1800S_L 170 220 4 5 800 2.2 150
P2100S_L 180 240 4 5 800 2.2 150
P2300S_L 190 260 4 5 800 2.2 150
P2600S_L 220 300 4 5 800 2.2 150
P3100S_L 275 350 4 5 800 2.2 150
P3500S_L 320 400 4 5 800 2.2 150
Surge Ratings in Amps
Series
IPP
ITSM
50 / 60 Hz di/dt
0.2x310 *
0.5x700 **
2x10 *
2x10 **
8x20 *
1.2x50 **
10x160 *
10x160 **
10x560 *
10x560 **
5x320 *
9x720 **
10x360 *
10x360 **
10x1000 *
10x1000 **
5x310 *
10x700 **
Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps/µs
A 20 150 150 90 50 75 75 45 75 20 500
B25 250 250 150 100 100 125 80 100 30 500
C 50 500 400 200 150 200 175 100 200 30 500
¨
SIDACtor® Device
Telecom Design Guide • © 2006 Littelfuse 3 - 3 www.littelfuse.com
SIDACtor Devices
* [A/B] in part number indicates that values are for both A and B surge ratings.
Note: Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
Thermal Considerations
Package Symbol Parameter Value Unit
DO-214AA TJOperating Junction Temperature Range -40 to +150 °C
TSStorage Temperature Range -65 to +150 °C
RθJA Thermal Resistance: Junction to Ambient 90 °C/W
Capacitance Values
Part Number *
pF
MIN MAX
P0080S[A/B]L 25 150
P0080SCL 35 260
P0220SAL 25 150
P0220SBL 25 150
P0220SCL 30 240
P0300S[A/B]L 15 140
P0300SCL 25 250
P0640S[A/B]L 40 60
P0640SCL 55 155
P0720SAL 35 60
P0720SBL 35 75
P0720SCL 50 150
P0900SAL 35 55
P0900SBL 35 70
P0900SCL 45 140
P1100SAL 30 50
P1100SBL 30 70
P1100SCL 45 115
P1300SAL 25 45
P1300SBL 25 60
P1300SCL 40 105
P1500SAL 25 40
P1500SBL 25 55
P1500SCL 35 95
P1800SAL 25 35
P1800SBL 25 50
P1800SCL 35 90
P2100S[A/B]L 20 35
P2100SCL 30 90
P2300SAL 25 35
P2300SBL 25 50
P2300SCL 30 80
P2600SAL 20 35
P2600SBL 20 45
P2600SCL 30 80
P3100SAL 20 35
P3100SBL 20 45
P3100SCL 30 70
P3500SAL 20 35
P3500SBL 20 40
P3500SCL 25 65
www.littelfuse.com 3 - 4 © 2006 Littelfuse • Telecom Design Guide
SIDACtor® Device
I
H
I
T
I
S
I
DRM
V
DRM
V
T
+
V
-V
+I
-I
V
S
V-I Characteristics
50
100
0
t
r
t
d
0
Peak
Value
Half Value
t – Time (µs)
I
PP
– Peak Pulse Current – %I
PP
t
r
= rise time to peak value
t
d
= decay time to half value
Waveform = t
r
x t
d
tr x td Pulse Waveform
-8
-40 -20 0 20 40 60 80 100 120 140 160
-6
-4
0
2
4
6
8
10
12
14
Junction Temperature (TJ) – ˚C
Percent of VS Change – %
25 ˚C
Normalized VS Change versus Junction Temperature
0.4
-40 -20 0 20 40 60 80 100 120 140 160
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
Case Temperature (TC) – ˚C
Ratio of
IH
IH (TC = 25 ˚C)
25 ˚C
Normalized DC Holding Current versus Case Temperature