m4. VA 90W AC-DC Reliable Green Medical Adaptor G S M o 0 B series MEAN WELL AL: CBFECE FAI EN60601-1 ANSI/AAMI ES60601-1 IEC60601-1 @ Features i Applications * 2 pole AC inlet IEC320-C8, Class II power unit * Mobile clinical workstation * Medical safety approved (2 x MOPP) according to * Oral irrigator ANSI/AAMI ES60601-1 and IEC/EN60601-1 * Portable hemodialysis machine * Extremely low leakage current * Breath Machine * No load power consumption<0.15W - Medical computer monitor * Energy efficiency level VI and meet CoC Version 5 * -30~+70C wide range working temperature * Protections: Short circuit / Overload / Over voltage / Over temperature * LED indicator for power on * Lifetime > 90 K hours * 3 years warranty MH Description GSM9QOB is a highly reliable, 9OW desktop style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100A), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 91% and the extremely low no-load power consumption below 0.15W, GSM90B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and meet Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM90B is approved with the international medical safety certificates. H Model Encoding DC plug type {ea M: Standard model,2.5x5.5x11mm,C+,tuning fork type Output voltage IEC320-C8 AC inlet Rated wattage Series name Other options available by customer requested (see Page 4~5) File Name:GSM90B-SPEC 2018-11-21GSM90B series 4 W 90W AC-DC Reliable Green Medical Adaptor SPECIFICATION ORDER NO. GSM90B12-P1M GSM90B15-P1M GSM90B19-P1M GSM90B24-P1M GSM90B48-P1M SAFETY MODEL NO. GSM90B12 GSM90B15 GSM90B19 GSM90B24 GSM90B48 DC VOLTAGE Note.2) 12V 15V 19V 24V 48V RATED CURRENT 6.67A 6A 4.74A 3.75A 1.87A CURRENT RANGE 0~6.67A 0~6A 0~4.74A 0~3.75A 0~1.87A RATED POWER (max.) 80W 90W 90W 90W 90W OUTPUT | RIPPLE & NOISE (max.) Note.3| 120mVp-p 120mVp-p 120mVp-p 180mVp-p 200mVp-p VOLTAGE TOLERANCE Note.4| 5.0% +5.0% +4.0% +3.0% +2.5% LINE REGULATION Note.5| 1.0% +1.0% +1.0% +1.0% +1.0% LOAD REGULATION +5.0% +5.0% +4.0% +3.0% +2.5% SETUP, RISE TIME Note.6| 1000ms, 50ms / 230VAC 1500ms, 50ms / 115VAC at full load HOLD UP TIME (Typ.) 30ms / 230VAC 20ms / 115VAC at full load VOLTAGE RANGE Note.7|80~ 264VAC 113~370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC PF>0.95 / 115VAC at full load INPUT EFFICIENCY (Typ.) 88% 89% 89% 90% 91% AC CURRENT (Typ.) 1.3A/ 115VAC 0.6A/ 230VAC INRUSH CURRENT (Typ.) Cold start 30A/115VAC 60A/ 230VAC LEAKAGE CURRENT(max.) | Touch current < 100A/264VAC OVERLOAD 110 ~ ies rated elna power __ Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 105 ~ 135% rated output voltage OVER VOLTAGE ; Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. -30 ~ +70C (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85C, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT =0.03% / C (0 ~ 40C) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.8} 3000 meters SAFETY STANDARDS IEC60601-1, EN60601-1/ EN60601-1-11, ANSI/AAMI ES60601-1 / ES60601-1-11(3.1 version), CANICSA-C22.2 No. 60601-1:14 - Edition 3, EAC TP TC 004 approved ISOLATION LEVEL Primary-Secondary: 2xMOPP WITHSTAND VOLTAGE \/P-O/P: 4KVAC ISOLATION RESISTANCE V/P-O/P:100M Ohms / 500VDC / 25C/ 70% RH Parameter Standard Test Level / Note Conducted emission ENSSOT (CISPR) FOC PART 1S7CISPRZ2, | 55g EMC EMISSION Radiated emission ENSSOT (CISPRIT) FOC PART 18/CISPR22,| Cass SAFETY & Harmonic current EN61000-3-2 Class A EMC Voltage flicker EN61000-3-3 0 (Note. 9) EN55024 , EN60601-1-2, EN61204-3 Parameter Standard Test Level / Note ESD EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact ; Level 3, 10V/m( 80MHz~2.7GHz ) RF field susceptibility EN61000-4-3 Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts EN61000-4-4 Level 3, 2KV EMC IMMUNITY Surge susceptibility EN61000-4-5 Level 3, 1KV/Line-Line Conducted susceptibility EN61000-4-6 Level 3, 10V Magnetic field immunity EN61000-4-8 Level 4, 30A/m 0, j i 0, i i Voltage dip, interruption EN61000-4-11 toon inerotons 505 oan Periods, MTBF 405.6K hrs min. MIL-HDBK-217F(25 C) OTHERS |DIMENSION 145*60*32mm (L*W*H) PACKING 0.45Kg; 30pcs/14.5Kg/1 CUFT CONNECTOR PLUG See page 4~5 ; Other type available by customer requested CABLE See page 4~5_; Other type available by customer requested NOTE 1. All parameters are specified at 230VAC input, rated load, 25C 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47f capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. 8. The ambient temperature derating of 3.5C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http:/Avww.meanwell.com) File Name:GSM90B-SPEC 2018-11-21m4. VA 90W AC-DC Reliable Green Medical Adaptor G S M o 0 B series MEAN WELL Hi Derating Curve Bi Static Characteristics 100 - 7 100 | VA 90 F I 4 80 | 80 4 ~ | s 60F 4 = 70 - + Q a S50 pmo rrr nnn nner nnn <= L 4 gw J 3g | 50 F 1 4 207 7 40 L 4 ! -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 90 100 110 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE (C) INPUT VOLTAGE (VAC) 60Hz Hi Mechanical Specification CaseNo.GS90A Unit: mm UL1185 14AWG 1000+50mm for 12 ~ 15V 30 445 UL1185 16AWG 1200+50mm for 19 ~ 48V | 70+10mm Power LED AC Inlet IEC320-C8 HDC output plug Standard plug: P1M P1M Pin Assignment 55 1140.5mm Gece G. Gre 2.5 Outside C-@ Inside File Name:GSM90B-SPEC 2018-11-21m4. VA 90W AC-DC Reliable Green Medical Adaptor G S M o 0 B series MEAN WELL Optional DC plug: . A B C Tuning Fork Style Type No. ar 7 7 Cc P1l 5.5 2.1 9.5 Co, PJ 5.5 2.1 11.0 A (Straight) P1L 5.5 2.5 9.5 iy , C P1IR 5.5 2.1 9.5 mi P1JR 5.5 2.1 11.0 (Right-angled) P1LR 5.5 2.5 9.5 P1MR 5.5 2.5 11.0 A B C Barrel Style Type No. a 7 7 C P2l 5.5 2.1 9.5 P2J 5.5 2.1 11.0 , ca a P2L 5.5 25 | 95 ~~ ry (Straight) | pam 5.5 25 | 11.0 OQ, C P2IR 5.5 21 | 95 7 Lo P2JR 5.5 21 | 11.0 P2LR 5.5 2.5 9.5 (Right-angled) | BaMR 5.5 25 | 11.0 Lock Style Type No. a . ; A Locking C P2S(S761K) 5.53 2.03 12.06 >. tS ea P2K(761K) 5.53 2.54 | 12.06 & , ( P2C(S760K) 5.53 2.03 9.52 SWITCHCRAFT original or equivalent P2D(760K) 5 53 2.54 9.52 A B C D Center Pin Style Type No. op | ID L Icomerrin A _o. P4A 55 | 34] 11.0] 1.0 con coe Mi] | P4B 65 | 44] 11.0] 14 EIAJ equivalent P4C 7.4 5.1 | 11.0 | 0.6 . oo. Pin Assignment Min. DIN 3 Pin with Lock (male) Type No. SINING Output - 1 +Vo We 5 Goel Sly Js R6B 2 Vo . % KYCON KPPX-3P equivalent 3 +Vo File Name:GSM90B-SPEC 2018-11-21m4. VA 90W AC-DC Reliable Green Medical Adaptor G S M o 0 B series MEAN WELL Min. DIN 4 Pin with Lock (mal Type No rin Assignment in. in with Lock (male) - BIN No. Output z { +Vo 23 S , (28) (Pl |g R7B 2 "Vo 8 4 3 -Vo KYCON KPPX-4P equivalent 4 +Vo Min. DIN 4 Pin with Lock (female) Type No Pin Assignment ock wemale "| PINNo. Output 1 +Vo 2 -Vo OO))\ 23 @ cml [| | wm. -+* KYCON KPJX-CM-4S equivalent 4 +Vo . Pin Assignment DIN 5 Pin (male) TypeNo. | airno. Output { -Vo 2 -Vo oy go ray R1B $25, | I HHH iS 3 +Vo 4 -Vo 5 +Vo : . Pin Assignment Stripped and tinned leads Type No. PIN No. Output L___ (red) = 1 1 +Vo CT 2 | L4 (black) by customer Length of Land L1 by request 2 Vo (MWs standard length, L:_25 mm, L1:_5 mm) Hf Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:GSM90B-SPEC 2018-11-21