June 1997 36 Vdc to 75 Vdc Input; 25 W
CW025 Dual Output-Series Power Modules:
Test Configurations (continued)
8-863(C).a
Note: All measurements are taken at the module terminals. When
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
Figure 13. Output Voltage and Efficiency Measure-
ment Test Setup
Design Considerations
Grounding Considerations
For modules without the isolated case ground pin
option, the case is internally connected to the VI(+) pin.
Input Source Impedance
The power module should be connected to a low ac-
impedance input source. Highly inductive source
impedances can affect the stability of the power mod-
ule. A 33 µF electrolytic capacitor (ESR < 0.7 Ω at
100 kHz) mounted close to the power module helps
ensure stability of the unit.
Note: VI(+) is internally connected to the case for a
standard module.
Safety Considerations
For safety agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e.,
UL
-1950,
CSA
22.2-950, EN60950.
For the converter output to be considered meeting the
requirements of saf ety extr a-low v oltage (SELV), one of
the following must be true of the dc input:
■All inputs are SELV and floating with the output also
floating.
■All inputs are SELV and grounded with the output
also grounded.
■Any non-SELV input must be provided with rein-
f orced insulation from an y other hazardous voltages,
including the ac mains, and must have an SELV reli-
ability test performed on it in combination with the
converters.
The pow er module has e xtr a-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a maxi-
mum 5 A normal blow fuse in the ungrounded lead.
Input/Output V oltage Reversal
CAUTION: Applying a reverse voltage across the
module input or output forward biases
an internal diode. Attempting to start
the module under this condition can
damage the module.
V
I
(+)
I
I
I
O
SUPPLY
CONTACT
RESISTANCE
CONTACT AND
DISTRIBUTION LOSSES
LOAD
V
I
(–)
V
O1
V
O2
COM
LOAD
η
VOJ COM–[]IOJ
J1=
2
∑
VI +() VI –()–[]II
----------------------------------------------------------------- x 100=