AIM & THURLBY THANDAR INSTRUMENTS QPX600D & QPX600DP 1200 watt dual dc power supply with PowerFlex+ Dual independent or tracking outputs of up to 600 watts each Variable voltage/current combinations over a very wide range Up to 80 volts and up to 50 amps within each power envelope Smart tracking and metering for easy series/parallel operation Analog, RS-232, USB, GPIB and LAN interfaces (QPX600DP) aimtti.com aimtti.co.uk | aimtti.us QPX600D - dual 600 watt dc power supply with PowerFlex+ 80V, 50A max. 80V 70V 60V QPX600D PowerFlex+ 50V Power Envelope 40V (600W max. per output) 30V 20V 10V 0V 0A 5A 10A 15A 20A 25A 30A 35A 40A 45A 50A The QPX600D is a dual output dc power supply with a maximum total output power of 1200 watts and is suited to both bench-top and system applications. The QPX600DP incorporates full digital remote control using USB, RS-232, LAN and GPIB interfaces. Both models include analog remote control. PowerFlex+ The QPX600D is a different type of laboratory power supply designed to meet the need for flexibility in the choice of voltage and current. A conventional PSU has a fixed current limit giving a power capability that reduces directly with the output voltage. The TTi PowerFlex+ design of the QPX600D enables higher currents to be generated at lower voltages within an overall power limit envelope. Each output can provide more than six times the current of a conventional PSU of the same maximum voltage and power (see power curve). PowerFlex+ uses a balanced multi-phase converter system to minimise ripple and improve dynamic performance. Example voltage/current combinations include 80V/7.5A, 60V/10A, 40V/15A, 28V/20A, 18V/30A and 10V/50A. Dual independent or tracking outputs The QPX600D can be operated as two entirely independent power supplies, each with its own comprehensive graphic LCD display. Alternatively multiple isolated tracking modes are available including ones intended for series and parallel operation which provide metering of total voltage or total current respectively. Tracking Modes: 1. V2 set = V1 set 2. V2 set = N% x V1 set, where N can be between 5% and 2000%. 3. V2 set = V1 set, I2 set = I1 set. Additional display metering shows the total current flowing (I1+I2 actual). This mode is intended for parallel wiring of the outputs. 4. V2 set = V1 set, I2 set = I1 set. Additional display metering shows total voltage generated (V1+V2). This mode is intended for series wiring of the outputs. Up to 160V or 100A The combination of PowerFlex+ regulation with series or parallel wiring of the outputs and the use of smart tracking and metering, enables a higher voltage or higher current single output power supply to be simulated. Bench or rack mounting The QPX600D is housed in a 350mm (133/4") wide case suitable for use on the bench-top. Output and remote sense terminals are mounted on the rear panel along with the analog and logic interface connectors and, on the QPX600DP, the bus interface connectors. The power supply is 3U high and a rack mounting kit (RM310A) is available as an option. Dual independent or tracking 600 watt outputs Ultra-wide range of voltage/current combinations Up to 80V and up to 50A within each power envelope Isolated tracking of voltage only, or voltage and current Smart metering and tracking functions facilitate series or parallel wiring for up to 160V or 100A Low output noise and ripple High setting resolution of 1mV Variable OVP and OCP trips Analog control interfaces for voltage and current GPIB, RS-232, USB and LAN (LXI) interfaces (QPX600DP) Independent or simultaneous output control The Both On and Both Off buttons are in addition to the individual switches for each output, and allow both outputs to be turned on or off synchronously by a single button press. Synchronous switching of the outputs is of increasing importance for circuitry which can lock-up or even be damaged if one voltage rail is present without the other. Power calculation The meter for each output can be set to show the total power currently being provided to the load (V x A) to a resolution of 0.1 watts. Low resistance calculation The meter for each output can be set to show the equivalent resistance of the load by displaying voltage divided by current. Low resistance measurements using a DMM utilise a low excitation current and suffer from thermal emf errors and other low voltage effects. This function enables low resistance measurements to be made at high currents by using the remote sense terminals to create a four terminal connection. This can give much more reliable results for certain component types, such as magnetics, which operate at ampere levels. QPX600DP - USB, RS-232, GPIB & LAN Graphic display for clarity and ease of use The QPX600D incorporates two high resolution graphic LCDs capable of showing numbers and text in a variety of sizes. The standard display mode shows voltage and current in large characters along with text annunciators such as CV mode and Output On. When settings are being changed, a dual display of parameters is used enabling existing and new settings, or actual and limit values to be viewed simultaneously. A similar arrangement is used with smart metering for series or parallel operation. More complex functions are provided with text prompts or complete selection menus. Current meter averaging When measuring rapidly varying loads it can become difficult to get useful readings from the current meter. By selecting meter averaging, the reading is stabilised by averaging the last four readings to reduce the speed and extent of the variation. Numeric or rotary entry Voltage and current levels can be set directly via the numeric keypad. Alternatively settings can be changed via the jog wheel at user selectable increments. Multiple settings stores Non-volatile stores are incorporated for rapid recall of voltage and current settings and are useful for repetitive testing applications. Separate stores are provided for each output. OVP and OCP trips Variable trips for over-voltage and over-current are provided on each output. Unlike a limit setting, the trip setting turns the output off and provides a different level of protection. For example, when repetitively testing a unit which normally takes a peak current of 10A, the current limit could be set to 11A and the OCP to 10.1A to ensure that a faulty unit will trip the supply off and not be damaged by over dissipation. The output trip can also be activated by other fault conditions including over temperature and remote sense mis-wiring. The cause of the trip is shown on the display. Analog and Logic interfaces Both models incorporate analog interfaces for voltage control of both output voltage and output current (non-isolated, one for each output). The control voltages are digitised to control the PSU and the scaling can be selected as 0 to 5V or 0 to 10V for zero to full scale. Monitor outputs for voltage and current are also provided, and can similarly be selected as 0 to 5V or 0 to 10V. An opto isolated logic control signal is provided for control of output on/off. This can be menu selected as true = output on, or true = output off. An opto isolated open-collector logic output signal is also available. This can be menu selected as true or false for output enabled or disabled, current limit, power limit, or any fault trip. QPX600DP - comprehensive bus remote control To meet a wide variety of needs, the QPX600DP adds a comprehensive array of digital bus interfaces. RS-232, USB, GPIB and LAN (Ethernet) with LXI support are all provided as standard. Each of the digital bus interfaces provides full control of voltage, current, output on/off and set-up, plus read-back of voltage, current and status. The interfaces are at ground potential and are opto-isolated from the output terminals. The GPIB interface is compliant with IEEE-488.1 and IEEE-488.2. Currently GPIB remains the most widely used interface for system applications. An RS-232/RS-423 interface is provided for use with legacy systems. This type of serial interface remains in common useage and is perfectly satisfactory for the control of power supplies because data speed is not an issue. USB provides a simple and convenient means of connection to a PC and is particularly appropriate for small system use. A USB driver is provided which supports Windows 2000, XP , Vista and Windows 7. The LAN interface uses a standard 10/100 base-T Ethernet hardware connection with ICMP and TCP/IP Protocol for connection to a Local Area Network or direct connection to a single PC. This interface supports LXI and is highly appropriate for system use because of its scalable nature and low cost interconnection. The LAN interface is compliant with LXI class C. LXI (LAN eXtensions for Instrumentation) is the nextgeneration, LAN-based modular architecture standard for automated test systems managed by the LXI Consortium, and is expected to become the successor to GPIB in many systems. For more information on LXI and how it replaces GPIB, or operates along side it, go to: www.tti-test.com/go/lxi IVI Driver An IVI driver for Windows is included. This provides support for common high-level applications such as LabView*, LabWindows*, and HP/ Agilent VEE*. * LabView and LabWindows are trademarks of National Instruments. HPVEE (now Agilent VEE) is a trademark of Agilent Technologies. * Windows is a trademark of Microsoft. Other models in the QPX series For those requiring only a single output power supply, the QPX1200 offers 1200 watts of PowerFlex performance from one output. Go here for details: www.tti-test.com/go/qpx QPX600D & QPX600DP - Technical Specifications OUTPUT SPECIFICATIONS (each Output) Voltage/Current Levels Voltage Range: Current Range: Power Range: Operating Mode: Output Setting Voltage Setting: Current Setting: Setting Accuracy: Setting Stores: Range 1 - 0V to 60V; Range 2 - 0V to 80V 0A to 50A. Up to 600W - see PowerFlex+ power envelope graph. Constant voltage or constant current with automatic cross-over and mode indication. By floating point numeric entry or rotary jog wheel; resolution 1mV for 60V range or 2mV for 80V range. By floating point numeric entry or rotary jog wheel; resolution 10mA. Voltage - 0.1% 2mV; 0.1% 4mV on 80V range Current - 0.3% 20mA Up to 10 set-ups can be saved and recalled via the keyboard (or the digital interfaces on QPX600DP). Keyboard & Rotary Control All functions, including the selection and set-up of the remote control interfaces, can be set from the keyboard. The rotary Jog control can be used to adjust output voltage and current settings in a quasi-analogue mode. The output to be controlled is first selected with the appropriate Control key. Output Performance Load regulation: Line regulation: Ripple & Noise: Transient Response: Temp. Coefficient: Sensing: Output Protection External Voltage: Power Limit: Fault Trip: Over Voltage (OVP): Over Current (OCP): Over Temperature: Sense Error: <0.01% +5mV (CV mode) for any load change within the PowerFlex envelope, using remote sense. <0.01% +5mV for a 10% line voltage change. Typically <3mV rms, <20mV pk-pk, (20MHz bandwidth). <2ms to within 100mV of set level for 5% to 95% load change. Typically <100ppm/oC. Selectable local or remote sensing. Output will withstand forward voltages of up to 90V. Reverse protection by diode clamp. Automatic protection within PowerFlex+ control system. The output will be shut down if any of the four trip conditions listed below occur. Settable 2V to 85V in 0.1V steps Settable 2A to 55A in 0.1A steps Monitors internal temperature rise to protect against excess ambient temperature or blocked ventilation slots. Monitors the voltage between the remote sense terminals and output terminals to protect against mis-wiring. Output Switching Push switch operating electronic power control. LED indication of On state Connection Output Terminals: Sensing Terminals: Rear mounted safety terminals accepting 6mm wire diameter, 6mm plugs or 8mm spades at 50 Amps max, or 4mm plugs at 30 Amps max. Screw-less terminals on rear panel. LINK MODES In addition to independent output operation, the instrument is capable of operating in a number of different voltage and current tracking modes which can be activated from the Link Menu. These modes include Output 2 voltage (V2) tracking Output 1 voltage (V1) by any ratio in the range 5% to 2000%, V2 and I2 set to track V1and I1 (1:1) with total V1 + V2 displayed (useful when Output 1 and Output 2 are series connected), V2 and I2 set to track V1and I1 (1:1) with total I1 + I2 displayed (useful when Output 1 and Output 2 are parallel connected). METERING (each Output) Display Type: Meter Function: Limits Display: Meter Resolution: Meter Accuracy: Large dot-matrix black-on-white backlit LCD. 5 digit voltage meter and 4 digit current meter. Display of limits values, memory contents etc. Wide range of alpha-numeric messages/menus. Limits settings can be displayed simultaneously with measurements. Voltage: 1mV (2mV on 80V range). Current: 10mA Voltage: 0.1% of reading 2 digits (CI mode and Unreg) Current: 0.3% of reading 2 digits (CV mode and Unreg) Additional Metering Functions V xA V/A Display shows calculated power in watts. Resolution 0.1W. Accuracy 0*5% 0*1W Display shows calculated resistance. Resolution up to 5 digits. Measurement uncertainty is shown on display. ANALOG & LOGIC INTERFACES (each Output) Analog Remote Control and Monitoring Non-isolated inputs and outputs to set voltage and current limit and to monitor actual output voltage and current. These signals are referenced to the negative output and have a range of 0 to 10V or 0 to 5V (selectable via the keyboard). Note that the analog control voltage is digitised within the power supply. Control Accuracy: Monitor Accuracy: Voltage: 0.3% 4mV; Current: 0.5% 40mA Voltage: 0.3% 4mV; Current: 0.5% 40mA Logic Control Input and Output LOGIC IN is a rear-panel opto-isolated input that is activated at an input current greater than approximately 1mA. User can set LOGIC IN (via the keyboard) to enable the output, disable the output, or be ignored when it is activated. LOGIC OUT is an isolated rear-panel open-collector output that will sink up to 2mA when activated (`switch closure'); the maximum voltage that can be applied to LOGIC OUT is 30VDC. User can set LOGIC OUT to be `closed' or `open' for output enabled or disabled, current limit (CI mode), power limit (UNREG mode), or for any fault trip. DIGITAL BUS INTERFACES (QPX600DP only) The QPX600DP offers full remote control and read-back using RS-232, USB, GPIB or LAN (compliant with LXI class C). All interfaces are at ground potential and opto-isolated from the output terminals. RS-232 Standard 9-pin D connector. Baud rate 9,600. USB USB 2.0 connection (backwards compatible with USB 1.x). Operates as a virtual COM port. GPIB (IEEE-488) The interface conforms with IEEE-488.1 and IEEE-488.2. Ethernet (LAN) Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol for connection to Local Area Network or direct connection to a single PC. LXI Compliance LAN interface is compliant with LXI class C. (LXI is the abbreviation for Lan eXtensions for Instrumentation). For more information visit: www.tti-test.com/go/lxi DIGITAL PROGRAMMING PERFORMANCE (QPX600DP only) Setting Accuracy and Resolution As per Manual Control (see Output Setting under Output Specifications) Programming Speed Command Delay: Typically <100ms between receiving the command terminator for a step voltage change at the instrument and the output voltage beginning to change. DRIVER SOFTWARE SUPPLIED (QPX600DP only) IVI Driver An IVI driver for Windows is supplied. This provides support for common applications such as LabView*, LabWindows*, HPVEE* etc. USB Driver An installation file is supplied which calls a standard Windows* USB driver. * LabView and LabWindows are trademarks of National Instruments. HPVEE (now Agilent VEE) is a trademark of Agilent Technologies. * USB interface is supported for Windows 2000, XP, and Vista. Windows is a trademark of Microsoft. GENERAL SPECIFICATIONS Input AC Input: Input Power: 110V to 240V AC 10%, 50/60Hz. Installation Category II. 1600VA max. Temperature & Environmental Operating Range: Storage Range: Environmental: Cooling: Safety & EMC Safety: EMC: Physical Size: Weight: +5C to +40C, 20% to 80% RH -40C to + 70C Indoor use at altitudes up to 2000m, Pollution Degree 2. Intelligent variable-speed fans. Complies with EN61010-1 Complies with EN61326 350 x 130 x 413mm (WxHxD) (3U height) . 9.2kg (20lb). OPTIONS Rack Mount (RM420) 19 inch 4U rack mount (provides ventilation space above and below PSU). Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Accuracy specifications apply for the temperature range 18C to 28C after 1 hour warm-up. Designed and built in Europe by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambridgeshire. PE29 7DR United Kingdom Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409 Email: sales@aimtti.com Web: www.aimtti.com Brochure Part No. 82100-1410 Iss 1A Product Summary Company name and product brands Laboratory Power Supplies Bench and system power supplies from 30 watts up to 1200 watts using linear, mixed-mode and PowerFlex regulation technologies. Thurlby Thandar Instruments Ltd. (TTi) is one of Europe's leading manufacturers of test and measurement instruments. Waveform Generators Analog and digital (DDS) function generators, true arbitrary generators, arbitrary/function generators and pulse generators. In the future, however, the full product range will be branded Aim-TTi. Products have been sold under two brand names: TTi and Aim. This changeover will be gradual and many products will continue to carry the TTi or Aim brands for some time to come. Web Addresses (URLs) Precision Measurement Instruments Benchtop DMMs, frequency counters, component measurement instruments (LCR), electronic dc loads, current probes. The preferred URL for obtaining information concerning Aim-TTi products is: www.aimtti.com (international customers) Customers in the UK should use the URL: www.aimtti.co.uk RF and EMC Test Equipment Spectrum analyzers, signal generators, frequency counters, power meters, emc measurement instruments. Customers in the USA should use the URL: www.aimtti.us Note that previous URLs such as www.tti-test.com will continue to operate for the time being. Designed and built in Europe by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambridgeshire PE29 7DR England (United Kingdom) Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409 Email: info@aimtti.com Web: www.aimtti.com