For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1True latching OVP is available as an option. Please add the suffix ‘-V’ to the
model number, e.g. EXA40-24S1V8-V. Additional alphanumeric suffixes
maybe added to indicate minor modifications not affecting the safety
approvals.
2Guaranteed minimum output voltage range.
3Latching OVP response time is 1ms (typical). OVP latch is reset by toggling
remote ON/OFF or by recycling the input voltage.
4Figures are percentage of minimum input voltage.
5Rshort ≤20mΩ.
6TVS spec : 6V8 @ 10mA, 10V5 @ 57A
4V1 @ 1mA, 7V3 @ 50A
7Maximum continuous output power.
40 Watts for S05 models
26.4 Watts for S3V3 models
22 Watts for S2V75 models
14.4 Watts for S1V8 models.
8User must provide recommended fuses in order to comply with safety
approvals.
9Maximum temperature on components Q100, Q102 and Q103 not to
exceed 120°C. See Application Note for details.
EXA40 Series
Single output
DC/DC CONVERTERS 40W High Efficiency DC/DC Converters 2
Please consult our website for the following items: ✔ Application Note ✔ Shortform Data Sheet www.artesyn.com
File Name: LF_EXA40.PDF Rev: 15 Jan 2002
INPUT OUTPUT NOMINAL OUTPUT TYPICAL MODEL
VOLTAGE VOLTAGE(2) OUTPUT VOLTAGE CURRENT (MAX.) EFFICIENCY NUMBER(1)
18-36VDC 1.5 to 2.0V 1.8V 8.0A 84% EXA40-24S1V8
18-36VDC 2.5 to 3.0V 2.75A 8.0A 87% EXA40-24S2V75
18-36VDC 3.0 to 3.6V 3.3V 8.0A 88% EXA40-24S3V3
18-36VDC 4.5 to 5.5V 5.0V 8.0A 90% EXA40-24S05
36-75VDC 1.5 to 2.0V 1.8V 8.0A 84% EXA40-48S1V8
36-75VDC 2.5 to 3.0V 2.75V 8.0A 86% EXA40-48S2V75
36-75VDC 3.0 to 3.6V 3.3V 8.0A 88% EXA40-48S3V3
36-75VDC 4.5 to 5.5V 5.0V 8.0A 91% EXA40-48S05
Figure 1: Natural Convection (0.1m/s) Typical derating, See Application Note.
100%
75%
50%
25%
0% 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C 100°C
DERATING CURVE
Output Power (%)
Output Power (%)
AMBIENT TEMPERATURE (°C)
27.5%
-40°C -30°C -20°C -10°C
EXA40-24S05
All other Models
INPUT SPECIFICATIONS MINIMUM TYPICAL MAXIMUM
Remote ON/OFF Active low, control to -Vin,
open collector input
ON Open circuit voltage 4.5V 5.5V
OFF 1.0V 2.5V
Remote ON/OFF source current -70µA -100µA
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
EMC CHARACTERISTICS (Continued)
ETS 300 386-1 table 5
Conducted emissions EN55022, internal filter Level A
(See Design Note 101) and 4.7µF film cap
EN55022, external filter, Level B
Radiated emissions EN55022 (See Design Note) Level B
ESD air EN61000-4-2, level 3
ESD contact EN61000-4-2, level 4
Surge (500V) EN61000-4-5, level 3,4
Fast transients EN61000-4-4, level 3,4
Radiated immunity EN61000-4-3, level 3
Conducted immunity EN61000-4-6, level 3
GENERAL SPECIFICATIONS
Efficiency See table
Basic insulation Input/output 1500VDC
Input fuse 24V (See Note 8) 3.5A slow blow
Input fuse 48V 2.0A slow blow
Switching frequency Fixed 300kHz
Approvals and (See Notes 1, 7, 8, 9) EN60950
standards Bi-national UL1950
(See Notes 1, 7, 8, 9) CSA C22.2 No. 234/950
Weight 25g (0.88 oz)
MTBF, See Design Note MIL-HDBK-217 250,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40°C to +70°C,
temperature See curves
Non-operating -55°C to +105°C
Over temperature Loss of Function 75°C to +85°C
shutdown Self-Recovery (LFS)
ETS 300 019-2-3 Classes T3.1 to T3.5
Air temperature Low: IEC 68-2-1 -40°C
High: IEC 68-2-2 +70°C
Change: IEC 68-2-1 -40°C to +70°C
Relative humidity IEC 68-2-56 10% to 100% RH
IEC 68-2-30 Condensation
Vibration, Class 3M5 IEC68-2-6 2 to 9 Hz, 3mm disp.
9 to 200Hz 1g
MIL-STD-202F Method 204 cond. A
Shock, Class 3M5 IEC-68-2-29
MIL-STD-202F Method 213B cond. A