Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ-G
ASCTB23E 201201-T1
ORDERING INFORMATION
TYPES
Standard packing: Carton 20 pcs., Case 500 pcs.
Slim type SSR for
1A and 2A control
AQ-G RELAYS
Type Load current Load voltage Input voltage Part No.
Zero-cross
1A 75 to 264 V AC
5 V DC AQG12105
12 V DC AQG12112
24 V DC AQG12124
2A 75 to 264 V AC
5 V DC AQG22105
12 V DC AQG22112
24 V DC AQG22124
Random
1A 75 to 264 V AC
5 V DC AQG12205
12 V DC AQG12212
24 V DC AQG12224
2A 75 to 264 V AC
5 V DC AQG22205
12 V DC AQG22212
24 V DC AQG22224
VDE
RoHS compliant
FEATURES
1. Space saving, Vertical size with a
maximum thickness of 4.5 mm.
Mounting space has been reduced to
30% (compared to conventional SSR’s)
while meeting high density PC board
mounting requirements.
2. Snubber circuit preventing
malfunction
3. Zero-cross type and Random type
available
4. High dielectric strength of
3,000V AC
(between input and output)
5. Snubber circuit integrated
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of voltage on the output side, such as
inductive load and current.
TYPICAL APPLICATIONS
Household appliances such as air
conditioners, refrigerators and
humidifiers
Healthcare and medical equipment
Industrial machinery such as NC
machines, mounters, injection
molders, and robots
Microcomputer boards
•Amusement and amenity related
equipment
Load current
1: 1 A
2: 2 A
AQG
Load voltage
2: 75 to 264 V AC
Type
1: Zero-cross (3,000 V)
2: Random (3,000 V)
Input voltage
05: 5 V DC
12: 12 V DC
24: 24 V DC
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ-G
ASCTB23E 201201-T1
RATING
1. Ratings (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
1) Zero-cross type
2) Random type
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
Item Type Part No. Remarks
AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124
Input
side
Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
*1
Input impedance Approx. 0.3k Approx. 0.8k Approx. 1.6k Approx. 0.3k Approx. 0.8k Approx. 1.6k
Drop-out
voltage, min. 1 V
Reverse voltage 3 V
Load
side
Max. load current 1 A AC*22 A AC*2
1A:
Ta = Max. 40°C 104°F
2A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 V AC
Frequency 45 to 65 Hz
Non-repetitive
surge current 8 A*330 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 1.5 mA at 60 Hz at 200 V AC
Max. “ON-state”
voltage drop 1.6 V at Max. carrying
current
Min. load current 20 mA*4
Item Type Part No. Remarks
AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224
Input
side
Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
*1
Input impedance Approx. 0.3k Approx. 0.8k Approx. 1.6k Approx. 0.3k Approx. 0.8k Approx. 1.6k
Drop-out
voltage, min. 1 V
Reverse voltage 3 V
Load
side
Max. load current 1 A AC*22 A AC*2
1A:
Ta = Max. 40°C 104°F
2A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 V AC
Frequency 45 to 65 Hz
Non-repetitive
surge current 8 A*330 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 1.5 mA at 60 Hz at 200 V AC
Max. “ON-state”
voltage drop 1.6 V at Max. carrying
current
Min. load current 20 mA*4
Item Zero-cross type Random type Remarks
Operate time max. 1/2 cycle of voltage sine wave + 1 ms 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Insulation resistance, min. 109 between input and output at 500 V DC
Breakdown voltage 3,000 Vrms between input and output for 1 min.
Vibration resistance 10 to 55 Hz double amplitude of 0.75 mm X, Y, Z axes
Shock resistance Min. 1,000 m/s2X, Y, Z axes
Ambient temperature –30°C to +80°C –22°F to +176°FNon-condensing at low
temperatures
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn-ON and Turn-OFF) Random turn ON, zero-cross turn OFF
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ-G
ASCTB23E 201201-T1
REFERENCE DATA
DIMENSIONS (mm inch)
1. Load current vs. ambient temperature
2.-(1) Non-repetitive surge current vs. carrying time
(1A type)
2.-(2) Non-repetitive surge current vs. carrying time
(2A type)
0.5
1.0
1.5
2.0
2.5
00-30 20 40 60 80
Ambient temperature, °C
Load current, A
1A type
2A type
0
4
2
10
8
6
110100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
10
5
40
30
35
25
15
20
110100
No. of cycles at 60 Hz
Non-repetitive surge current, A
3. Input current vs. input voltage characteristics 4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
(1A type)
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(2A type)
5
10
15
20
25
30
10 155020253530
Input voltage, V
Input current, mA
(5 V type) (12 V type) (24 V type)
1.0
1.2
0.8
0.6
0.2
0.4
0200-30 40 60 80
Ambient temperature, °C
=15 mm
.591 inch
=10 mm
.394 inch
=5 mm
.197 inch
= Adjacent mounting pitch
Load current, A
2.0
2.5
1.5
1.0
0.5
0200-30 40 60 80
Ambient temperature, °C
=15 mm
=10mm
=5mm
.591 inch
.394 inch
.197 inch
= Adjacent mounting pitch
Load current, A
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. 1A type External dimensions
General tolerance: ±0.2 ±.008
24.5 max.
4-0.7
4-1.6
2.54 10.16 7.62
1.2
0.25
4.5 max.
13.5 max.
0.8
3.7
.965 max.
4-.028
4-.063
.100 .400 .300
.047
.010
.177 max.
.531 max.
.031
.146
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
2.54 10.16 7.62
4-1.0 dia.
1.2
.100 .400 .300
4-.039 dia.
.047
OutputInput
+
CAD Data
2. 2A type External dimensions
General tolerance: ±0.2 ±.008
24.5 max.
7.6210.162.54
4-1.6
4-0.7
4.5 max.
0.25
1.2
20.5 max.
0.8
3.7
.965 max.
.300.400.100
4-.063
4-.028
.177 max.
.010
.047
.807 max.
.031
.146
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
2.54 10.16 7.62
4-1.0 dia.
1.2
.100 .400 .300
4-.039 dia.
.047
OutputInput
+
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ-G
ASCTB23E 201201-T1
Recommended Temperature Controllers
48mm
56mm
1.890inch
2.205inch
48mm
1.890inch
<KT4H Temperature Controller>
Our temperature controller is recommended for use with our Solid State Relays.
Features
• Space saving requiring only a depth of 65 mm
• Data collection possible through a PLC using RS485 communication
Tool port is standard for easy data setting
• Inverted LCD + backlight for good legibility with large characters
• Excellent operability and rich optional control functions
Substitute part numbers
*For detailed product information about temperature controllers, please refer to our website:
http://industrial.panasonic.com/ac/e/
Power supply Control output Part No.
100 to 240 V AC Non-contact voltage output AKT4H112100