SPECIFICATION
DR-60-5 DR-60-12 DR-60-15 DR-60-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V 15V 24V
6.5A 4.5A 4A 2.5A
0 ~ 6.5A 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A
32.5W 54W 60W 60W
80mVp-p 120mVp-p 120mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
±2.0% ±1.0% ±1.0% ±1.0%
11.1 ~ 13.2V4.75 ~ 5.5V
±1.0% ±1.0% ±1.0% ±1.0%
±1.0% ±1.0% ±1.0% ±1.0%
100ms, 30ms/230VAC 200ms, 30ms/115VAC at full load
100ms/230VAC 23ms/115VAC at full load
88 ~ 264VAC 124 ~ 370VDC
47 ~ 63Hz
76% 82% 83% 84%
1.2A/115VAC 0.8A/230VAC
COLD START 18A/115VAC 36A/230VAC
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.9V
Protection type : Shut down o/p voltage, re-power on to recover
13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
216.2K hrs min. MIL-HDBK-217F (25)
78*93*56mm (W*H*D)
0.3Kg; 48pcs/15.4Kg/1.02CUFT





File Name:DR-60-SPEC 2017-07-07
Compliance to EN55011, EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
60W Single Output Industrial DIN Rail Power Supply DR-60 series










RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
UL60950-1, TUV EN60950-1 approved, Design refer to EN50178
..
EMC IMMUNITY
EMC EMISSION
NRND
-20 0 10 20 30 40 50 60 70 (VERTICAL)
20
40
60
80
100
Block Diagram
AMBIENT TEMPERATURE ()
LOAD (%)
Mechanical Specification
File Name:DR-60-SPEC 2017-07-07
Terminal Pin No. Assignment
Pin No. Pin No.
2
1 5,6
3,4
7
8
Assignment Assignment
+V
AC/N
AC/L
-V
LED
+V ADJ.
PWM CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
CONTROL
O.V.P.
3
Derating Curve
Case No.918B Unit:mm
60W Single Output Industrial DIN Rail Power Supply DR-60 series
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
45
68
93
46.5
27.4
47
56
46.5
6
5 5 5 5
5
3
4
2
37.75
1
35
78
12.2
7
8
NRND