www.austriamicrosystems.com/Supervisors/AS1910 Revision 1.03 5 - 16
AS1910 - AS1915
Datasheet - Electrical Characteristics
Reset Threshold
Temperature Co efficient 60 ppm/ºC
Reset Threshold Hysteresis 8 x VTH mV
VRESETIN
TH RESETIN Threshold VRESETINTH Falling, TAMB = 0 to +85ºC 0.615 0.630 0.645 V
TAMB = -40 to +125ºC 0.61 0.65
RESETIN Hysteresis 8 x VTH mV
IRESETIN RESETIN Input Current 2TAMB = -40 to +85ºC -25 +25 nA
TAMB = -40 to +125ºC -100 +100
tRD VCC to Reset
Output Delay VCC = VTH to (VTH - 100mV) 55 µs
RESETIN to Reset
Output Delay VRESETIN = VRESETINTH to
(VRESETINTH - 30mV) 45 µs
tRP Reset Timeout Period TAMB = -40 to +85ºC 140 215 280 ms
TAMB = -40 to +125ºC 100 320
VOL RESETN Output Low
(Push/Pull or Open-Drain)
VCC ≥ 1.0V, ISINK = 50µA,
Reset Asserted, TAMB = 0 to +85ºC 0.3
V
VCC ≥ 1.2V, ISINK = 100µ A, Reset Asserted 0.3
VCC ≥ 2.55V, ISINK = 1.2mA,
Reset Asserted 0.3
VCC ≥ 3.3V, ISINK = 3.2mA,
Reset Asserted 0.4
VOH RESETN Output High
(Push/Pull Only)
VCC ≥ 1.8V, ISOURCE = 200µA,
Reset Not Asserted 0.8 x
VCC
V
VCC ≥ 3.15V, ISOURCE = 500µA,
Reset Not Asserted 0.8 x
VCC
VCC ≥ 3.3V, ISOURCE = 800µA,
Reset Not Asserted 0.8 x
VCC
ILKG Open-Drain RESETN Output Leakage
Current RESETN Not Asserted 1.0 µA
TAMB = +25 º C 0.2
VOH RESET Output High
(Push/Pull Only)
VCC ≥ 1.0V, ISOURCE = 1µA,
Reset Asserted, TAMB = 0 to +85ºC 0.8 x
VCC
V
VCC ≥ 1.50V, ISOURCE = 100µA,
Reset Asserted 0.8 x
VCC
VCC ≥ 2.55V, ISOURCE = 500µA,
Reset Asserted 0.8 x
VCC
VCC ≥ 3.3V, ISOURCE = 800µA,
Reset Asserted 0.8 x
VCC
VOL RESET Output Low
(Push/Pull Only)
VCC ≥ 1.8V, ISINK = 500µA,
Reset Asserted 0.3
V
VCC ≥ 3.15V, ISINK = 1.2mA,
Reset Asserted 0.3
VCC ≥ 3.3V, ISINK = 3.2mA,
Reset Asserted 0.4
Manual Reset Input
VIL MRN Input voltage
0.3 x
VCC V
VIH 0.7 x
VCC
MRN Minimum Input Pulse 1 µs
MRN Transient Rejection 90 ns
Table 4. Electrical Characteristics
Symbol Parameter 1Conditions Min Typ Max Units