DESCRIPTION
The VCNL4020C is a fully integrated biosensor and ambient
light sensor. Fully integrated means that the infrared emitter
is included in the package. It has 16 bit resolution. It
includes a signal processing IC and features standard I2C
communication interface. It features an interrupt function.
APPLICATIONS
Wearables
Health monitoring
•Pulse oximetry
FEATURES
Package type: surface-mount
Package form: SMD
Dimensions (L x W x H in mm): 4.90 x 2.40 x 0.83
Integrated modules: infrared emitter (IRED),
ambient light sensor (ALS), photo diode (PD),
and signal conditioning IC
Interrupt function
Supply voltage range VDD: 2.5 V to 3.6 V
Supply voltage range IR anode: 2.5 V to 5 V
Communication via I2C interface
•I
2C bus H-level range: 1.7 V to 5 V
Floor life: 72 h, MSL 4, according to J-STD-020
Low stand by current consumption: 1.5 μA
Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
OPTICAL BIOSENSORS FUNCTION
Built-in infrared emitter and broader sensitivity
photodiode allows to also work with green and red LEDs
16 bit effective resolution ensures excellent cross talk
immunity
Programmable LED drive current from 10 mA to 200 mA in
10 mA steps
Excellent ambient light suppression through signal
modulation
AMBIENT LIGHT FUNCTION
Built-in ambient light photo-pin-diode with
close-to-human-eye sensitivity
16 bit dynamic range from 0.25 lx to 16 klx
100 Hz and 120 Hz flicker noise rejection
Note
(1) Adjustable through I2C interface
7 nc
6 nc
9 GND
8 GND
10 IR cathode
IR anode 1
SDA 2
INT 3
SCL 4
VDD 5
22620
PRODUCT SUMMARY
PART
NUMBER
OPERATING
VOLTAGE
RANGE
(V)
I2C BUS
VOLTAGE
RANGE
(V)
LED PULSE
CURRENT (1)
(mA)
AMBIENT
LIGHT
RANGE
(lx)
SPECTRAL
BANDWIDTH
RANGE
λ0.5 (nm)
OUTPUT
CODE
ADC RESOLUTION
BIOSENSOR / AMBIENT
LIGHT SENSOR
VCNL4020C 2.5 to 3.6 1.7 to 5 10 to 200 0.25 to 16 383 550 to 970 16 bit, I2C 16 bit / 16 bit
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 2Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Note
(1) MOQ: minimum order quantity
ORDERING INFORMATION
ORDERING CODE PACKAGING VOLUME (1) REMARKS
VCNL4020C-GS08 Tape and reel MOQ: 3300 pcs 4.90 mm x 2.40 mm x 0.83 mm
VCNL4020C-GS18 MOQ: 13 000 pcs
ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. MAX. UNIT
Supply voltage VDD -0.3 5.5 V
Operation temperature range Tamb -25 +85 °C
Storage temperature range Tstg -25 +85 °C
Total power dissipation Tamb 25 °C Ptot -50mW
Junction temperature Tj-100°C
BASIC CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Supply voltage VDD 2.5 - 3.6 V
Supply voltage IR anode 2.5 - 5 V
I2C bus H-level range 1.7 - 5 V
INT H-level range 1.7 - 5 V
INT low voltage 3 mA sink current - - 0.4 V
Current consumption Standby current,
no LED-operation -1.5A
Current consumption
pulse mode incl. LED
(averaged)
2 measurements per second,
LED current 20 mA -5-μA
250 measurements per second,
LED current 20 mA - 520 - μA
2 measurements per second,
LED current 200 mA -35-μA
250 measurements per second,
LED current 200 mA -4-mA
Current consumption ambient
light mode
2 measurements per second
averaging = 1 -2.5-μA
8 measurements per second
averaging = 1 -10-μA
2 measurements per second
averaging = 64 - 160 - μA
8 measurements per second
averaging = 64 - 640 - μA
Ambient light resolution Digital resolution (LSB count ) - 0.25 - lx
Ambient light output EV = 100 lx
averaging = 64 - 400 - counts
I2C clock rate range fSCL - - 3400 kHz
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 3Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
CIRCUIT BLOCK DIAGRAM
Note
nc must not be electrically connected
Pads 6 and 7 are only considered as solder pads
TEST CIRCUIT
BASIC CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
Fig. 1 - Idle Current vs. Ambient Temperature
Fig. 2 - Idle Current vs. VDD
Fig. 3 - Proximity Value vs. Distance
Fig. 4 - Forward Current vs. Temperature
10 IR cathode
9 GND
8 GND
6 nc
7 nc
IR anode 1
SDA 2
INT 3
SCL 4
VDD 5
IRED
VCNL4020C
ASIC
Ambi
PD
PD
d = 20 mm
Kodak gray card
(18 % reectivity)
VCNL4020C IRED
30 mm x 30 mm
PD
2.4
1.0
1.2
1.4
1.8
1.6
2.0
2.2
110- 50
- 30
10 50 90
- 10
30 70
IDD - Supply Current Idle Mode (μA)
Tamb - Ambient Temperature (°C)22301
V
DD
= 3.6 V
V
DD
= 3.5 V
V
DD
= 3.3 V
V
DD
= 3.1 V V
DD
= 2.5 V
V
DD
= 2.7 V
V
DD
= 2.9 V
2.4
1.0
1.2
1.4
1.6
1.8
2.0
2.2
3.82.4 2.6 2.8 3.0 3.2 3.4 3.6
I
DD
- Supply Current Idle Mode (μA)
V
DD
- Supply Voltage (V)
22302
100 °C
80 °C
55 °C
25 °C
-10 °C
-40 °C
100 000
1
100
1000
10 000
10
0.1
1
10 100
Proximity Value (cts)
Distance to Reecting Card (mm)
LED current 200 mA
Media: Kodak gray card
Mod. frequency = 390 kHz
LED current 100 mA
LED current 20 mA
250
0
50
100
150
200
140-60
-20
20 60 100
I
IRED
- Forward Current IRED (mA)
T
amb
- Ambient Temperature (°C)
22304
20 mA
40 mA
60 mA
80 mA
100 mA
120 mA
140 mA
160 mA
180 mA
200 mA
VIRED = 2.5 V
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 4Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 5 - Relative Radiant Intensity vs. Wavelength
Fig. 6 - Relative Radiant Intensity vs. Angular Displacement
Fig. 7 - Relative Spectral Sensitivity vs. Wavelength
(Biosensor)
Fig. 8 - Relative Radiant Sensitivity vs. Angular Displacement
(Proximity Sensor)
Fig. 9 - Ambient Light Value vs. Illuminance
Fig. 10 - Relative Spectral Sensitivity vs. Wavelength
(Ambient Light Sensor)
1.1
0
0.2
0.4
0.6
0.8
0.9
1.0
0.1
0.3
0.5
0.7
1050750
800
850 900 950 1000
I
e, rel
- Relative Radiant Intensity
λ - Wavelength (nm)
22305
I
F
= 100 mA
20°
40°
60°
80°
0.6
0.7
0.8
0.9
1.0
00.10.20.30.40.5
I
rel
- Relative Radiant Intensity
22306
ϕ - Angular Displacement
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
400 500 600 700 800 900 1000 1100
S(λ)rel - Relative Spectral Sensitivity
λ- Wavelength (nm)
20°
40°
60°
80°
0.6
0.7
0.8
0.9
1.0
00.10.20.30.40.5
Srel - Relative Sensitivity
22308
ϕ - Angular Displacement
100 000
1
100
1000
10 000
10
Ambient Light Signal (cts)
EV - Illuminance (lx)
0.1 1 10 100 1000 10 000
0
0.2
0.4
0.6
0.8
1.0
1100400
500
600 700 800 900 1000
S(λ)rel - Relative Spectral Sensitivity
λ - Wavelength (nm)
VCNL4020C
Human eye
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 5Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 11 - Relative Radiant Sensitivity vs. Angular Displacement
(Ambient Light Sensor)
APPLICATION INFORMATION
The digital biosensor VCNL4020C needs just one decoupling-C at VDD if connected to a regulated power supply.
IR cathode needs no external connection as the connection to the driver is done internally, but this allows also for adding
external LEDs / IREDs to the driver.
1. Application Circuit
Fig. 12 - Application Circuit
(x) = Pin Number
Note
The interrupt pin is an open drain output. The needed pull-up resistor may be connected to the same supply voltage as the application
controller and the pull-up resistors at SDA / SCL. Proposed value R2 should be >1 kΩ , e.g. 10 kΩ to 100 kΩ.
Proposed value for R3 and R4, e.g. 2.2 kΩ to 4.7 kΩ, depend also on the I2C bus speed.
For detailed description about set-up and use of the interrupt as well as more application related information see AN: “Designing
VCNL4020C into an Application”.
20°
40°
60°
80°
0.6
0.7
0.8
0.9
1.0
00.10.20.30.40.5
Srel - Relative Sensitivity
22311
Vertical
Horizontal
ϕ - Angular Displacement
INT (3)
SCL (4)
SDA (2)
GND (8, 9)
VDD (5)
IR anode (1)
C1
470 nF
VCNL4020C
I2C bus clock SCL
I2C bus data SDA
INT (3)
SCL (4)
SDA (2)
GND (8, 9)
VDD (5)
IR anode (1)
C1 C2
C3C4
R1
100 nF
100 nF10 μF
22 μF
10R
GPIO
2.5 V
to
5.0 V
1.7 V
to
5.0 V
R2 R3 R4
IR cathode (10)
VSMD66694
IR
RED
(4)
(1)
(2)
(3)
VCNL4020C
Host
Micro Controller
2.5 V
to
3.6 V
2.5 V
to
3.6 V
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 6Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
2. I2C Interface
The VCNL4020C contains seventeen 8 bit registers for operation control, parameter setup and result buffering. All registers are
accessible via I2C communication. Figure 13 shows the basic I2C communication with VCNL4020C.
The built in I2C interface is compatible with all I2C modes (standard, fast and high speed).
I2C H-level range = 1.7 V to 5 V.
Please refer to the I2C specification from NXP for details.
Fig. 13 - Send Byte/Receive Byte Protocol
Device Address
The VCNL4020C has a fix slave address for the host
programming and accessing selection. The predefined 7 bit
I2C bus address is set to 0010 011 = 13h. The least
significant bit (LSB) defines read or write mode. Accordingly
the bus address is set to 0010 011x = 26h for write, 27h for
read.
Register Addresses
VCNL4020C has seventeen user accessible 8 bit registers.
The register addresses are 80h (register #0) to 90h
(register #16).
REGISTER FUNCTIONS
Register #0 Command Register
Register address = 80h
The register #0 is for starting ambient light or biosensor measurements. This register contains 2 flag bits for data ready
indication.
Note
With setting bit 3 and bit 4 at the same write command, a simultaneously measurement of ambient light and biosensor is done. Beside als_en
and / or bs_en first selftimed_en needs to be set. On-demand measurement modes are disabled if selftimed_en bit is set. For the
selftimed_en mode changes in reading rates (reg #4 and reg #2) can be made only when b0 (selftimed_en bit) = 0. For the als_od mode
changes to the reg #4 can be made only when b4 (als_od bit) = 0; this is to avoid synchronization problems and undefined states between
the clock domains. In effect this means that it is only reasonable to change rates while no selftimed conversion is ongoing.
SSlave address
Rd
Receive byte Read data from VCNL4020C
ARegister address A
Wr P
SSlave address PA
AData byte
Send byte Write command to VCNL4020C
S = start condition
P = stop condition
A = acknowledge
Host action
VCNL4020C response
SSlave address A Register address A
Wr P
Data byte A
TABLE 1 - COMMAND REGISTER #0
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
config_lock als_data_rdy bs_data_rdy als_od bs_od als_en bs_en selftimed_en
Description
config_lock Read only bit. Value = 1
als_data_rdy Read only bit. Value = 1 when ambient light measurement data is available in the result registers. This bit
will be reset when one of the corresponding result registers (reg #5, reg #6) is read.
bs_data_rdy Read only bit. Value = 1 when biosensor measurement data is available in the result registers. This bit
will be reset when one of the corresponding result registers (reg #7, reg #8) is read.
als_od
R/W bit. Starts a single on-demand measurement for ambient light. If averaging is enabled, starts a
sequence of readings and stores the averaged result. Result is available at the end of conversion for
reading in the registers #5(HB) and #6(LB).
bs_od R/W bit. Starts a single on-demand measurement for biosensor.
Result is available at the end of conversion for reading in the registers #7(HB) and #8(LB).
als_en R/W bit. Enables periodic als measurement
bs_en R/W bit. Enables periodic biosensor measurement
selftimed_en R/W bit. Enables state machine and LP oscillator for self timed measurements; no measurement is
performed until the corresponding bit is set
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 7Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Register #1 Product ID Revision Register
Register address = 81h. This register contains information about product ID and product revision.
Register data value of current revision = 21h.
Register #2 Rate of Biosensor Measurement
Register address = 82h.
Note
If self_timed measurement is running, any new value written in this register will not be taken over until the mode is actualy cycled.
Register #3 LED Current Setting for Biosensor Mode
Register address = 83h. This register is to set the LED current value for biosensor measurement.
The value is adjustable in steps of 10 mA from 0 mA to 200 mA.
This register also contains information about the used device fuse program ID.
TABLE 2 - PRODUCT ID REVISION REGISTER #1
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Product ID Revision ID
Description
Product ID Read only bits. Value = 2
Revision ID Read only bits. Value = 1
TABLE 3 - BIOSENSOR RATE REGISTER #2
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
n/a Rate of biosensor Measurement (no. of
measurements per second)
Description
Biosensor rate
R/W bits.
000 - 1.95 measurements/s (DEFAULT)
001 - 3.90625 measurements/s
010 - 7.8125 measurements/s
011 - 16.625 measurements/s
100 - 31.25 measurements/s
101 - 62.5 measurements/s
110 - 125 measurements/s
111 - 250 measurements/s
TABLE 4 - LED CURRENT REGISTER #3
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Fuse prog ID LED current value
Description
Fuse prog ID Read only bits.
Information about fuse program revision used for initial setup/calibration of the device.
LED current value
R/W bits. LED current = Value (dec.) x 10 mA.
Valid Range = 0 to 20d. e.g. 0 = 0 mA, 1 = 10 mA, …., 20 = 200 mA (2 = 20 mA = DEFAULT)
LED Current is limited to 200 mA for values higher as 20d.
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 8Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Register #4 Ambient Light Parameter Register
Register address = 84h.
Note
If self_timed measurement is running, any new value written in this register will not be taken over until the mode is actualy cycled.
Register #5 and #6 Ambient Light Result Register
Register address = 85h and 86h. These registers are the result registers for ambient light measurement readings.
The result is a 16 bit value. The high byte is stored in register #5 and the low byte in register #6.
TABLE 5 - AMBIENT LIGHT PARAMETER REGISTER #4
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Cont. conv.
mode als_rate Auto offset
compensation
Averaging function
(number of measurements per run)
Description
Cont. conversion mode
R/W bit. Continuous conversion mode.
Enable = 1; Disable = 0 = DEFAULT
This function can be used for performing faster ambient light measurements. This mode should only be
used with ambient light on-demand measurements. Do not use with self-timed mode. Please refer to the
application information chapter 3.3 for details about this function.
Ambient light measurement rate
R/W bits. Ambient light measurement rate
000 - 1 samples/s
001 - 2 samples/s = DEFAULT
010 - 3 samples/s
011 - 4 samples/s
100 - 5 samples/s
101 - 6 samples/s
110 - 8 samples/s
111 - 10 samples/s
Auto offset compensation
R/W bit. Automatic offset compensation.
Enable = 1 = DEFAULT; Disable = 0
In order to compensate a technology, package or temperature related drift of the ambient light values
there is a built in automatic offset compensation function.
With active auto offset compensation the offset value is measured before each ambient light
measurement and subtracted automatically from actual reading.
Averaging function
R/W bits. Averaging function.
Bit values sets the number of single conversions done during one measurement cycle. Result is the
average value of all conversions.
Number of conversions = 2decimal_value e.g. 0 = 1 conv., 1 = 2 conv, 2 = 4 conv., ….7 = 128 conv.
DEFAULT = 32 conv. (bit 2 to bit 0: 101)
TABLE 6 - AMBIENT LIGHT RESULT REGISTER #5
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
Read only bits. High byte (15:8) of ambient light measurement result
TABLE 7 - AMBIENT LIGHT RESULT REGISTER #6
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
Read only bits. Low byte (7:0) of ambient light measurement result
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 9Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Register #7 and #8 Biosensor Measurement Result Register
Register address = 87h and 88h. These registers are the result registers for biosensor measurement readings.
The result is a 16 bit value. The high byte is stored in register #7 and the low byte in register #8.
Register #9 Interrupt Control Register
Register address = 89h.
TABLE 8 - BIOSENSOR RESULT REGISTER #7
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
Read only bits. High byte (15:8) of biosensor measurement result
TABLE 9 - BIOSENSOR RESULT REGISTER #8
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
Read only bits. Low byte (7:0) of biosensor measurement result
TABLE 10 - INTERRUPT CONTROL REGISTER #9
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Int count exceed n/a INT_BS_
ready_EN
INT_ALS_
ready_EN INT_THRES_EN INT_THRES_
SEL
Description
Int count exceed
R/W bits. These bits contain the number of consecutive measurements needed above/below the
threshold
000 - 1 count = DEFAULT
001 - 2 count
010 - 4 count
011 - 8 count
100 -16 count
101 - 32 count
110 - 64 count
111 - 128 count
INT_BS_ready_EN R/W bit. Enables interrupt generation at biosensor data ready
INT_ALS_ ready_EN R/W bit. Enables interrupt generation at ambient data ready
INT_THRES_EN R/W bit. Enables interrupt generation when high or low threshold is exceeded
INT_THRES_SEL R/W bit. If 0: thresholds are applied to biosensor measurements
If 1: thresholds are applied to als measurements
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 10 Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Register #10 and #11 Low Threshold
Register address = 8Ah and 8Bh. These registers contain the low threshold value. The value is a 16 bit word. The high byte is
stored in register #10 and the low byte in register #11.
Register #12 and #13 High Threshold
Register address = 8Ch and 8Dh. These registers contain the high threshold value. The value is a 16 bit word. The high byte is
stored in register #12 and the low byte in register #13.
Register #14 Interrupt Status Register
Register address = 8Eh. This register contains information about the interrupt status for either biosensor or ALS function and
indicates if high or low going threshold exceeded.
Note
Once an interrupt is generated the corresponding status bit goes to 1 and stays there unless it is cleared by writing a 1 in the corresponding
bit. The int pad will be pulled down while at least one of the status bit is 1.
TABLE 11 - LOW THRESHOLD REGISTER #10
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
R/W bits. High byte (15:8) of low threshold value
TABLE 12 - LOW THRESHOLD REGISTER #11
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
R/W bits. Low byte (7:0) of low threshold value
TABLE 13 - HIGH THRESHOLD REGISTER #12
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
R/W bits. High byte (15:8) of high threshold value
TABLE 14 - HIGH THRESHOLD REGISTER #13
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Description
R/W bits. Low byte (7:0) of high threshold value
TABLE 15 - INTERRUPT STATUS REGISTER #14
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
n/a int_bs_ready int_als_ready int_th_low int_th_hi
Description
int_bs_ready R/W bit. Indicates a generated interrupt for biosensor
int_als_ready R/W bit. Indicates a generated interrupt for als
int_th_low R/W bit. Indicates a low threshold exceed
int_th_hi R/W bit. Indicates a high threshold exceed
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 11 Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Register #15 Biosensor Modulator Timing Adjustment
Register address = 8Fh.
Note
The settings for best performance will be provided by Vishay. With first samples this is evaluated to:
Delay time = 0; dead time = 1 and BS frequency = 00. With that register #15 should be programmed with 1 (= default value).
Register #16 Ambient IR Light Level Register
Register address = 90h.
This register is not intended to be used by customer.
3. IMPORTANT APPLICATION HINTS AND EXAMPLES
3.1 Receiver standby mode
In standby mode the receiver has the lowest current consumption of about 1.5 μA. In this mode only the I2C interface is active.
This is always valid, when there are no measurement demands executed. Also the current sink for the LED is inactive, so there
is no need for changing register #3 (LED current).
3.2 Data Read
In order to get a certain register value, the register has to be addressed without data like shown in the following scheme. After
this register addressing, the data from the addressed register is written after a subsequent read command.
Fig. 14 - Send Byte / Receive Byte Protocol
The stop condition between these write and read sequences is not mandatory. It works also with a repeated start condition.
Note
For reading out 2 (or more) subsequent registers like the result registers, it is not necessary to address each of the registers separately. After
one read command the internal register counter is increased automatically and any subsequent read command is accessing the next
register.
TABLE 16 - BIOSENSOR MODULATOR TIMING ADJUSTMENT #15
Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
Modulation delay time Biosensor frequency Modulation dead time
Description
Modulation delay time
R/W bits. Setting a delay time between LED signal and detectors input signal evaluation.
This function is for compensation of delays from LED and photo diode. Also in respect to the possibility
for setting different proximity signal frequency. Correct adjustment is optimizing measurement signal
level. (DEFAULT = 0)
Biosensor frequency
R/W bits. Setting the biosensor test signal frequency
The biosensor measurement is using a square signal as measurement signal. Four different values are
possible:
00 = 390.625 kHz (DEFAULT)
01 = 781.25 kHz
10 = 1.5625 MHz
11 = 3.125 MHz
Modulation dead time
R/W bits. Setting a dead time in evaluation of LED signal at the slopes of the signal. (DEFAULT = 1)
This function is for reducing of possible disturbance effects.
This function is reducing signal level and should be used carefully.
SSlave address
Rd
Receive byte Read data from VCNL4020C
ARegister address AWr P
SSlave address PA
AData byte
S = start condition
P = stop condition
A = acknowledge
Host action
VCNL4020C response
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 12 Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Example: read register “Ambient Light Result Register” #5 and #6:
Addressing:command: 26h, 85h (VCNL4020C_I2C_Bus_Write_Adr., Ambient Light Result Register #5 [85])
Read register #5:command: 27h, data (VCNL4020C_I2C_Bus_Read_Adr., {High Byte Data of Ambient Light Result register #5
[85])}
Read register #6:command: 27h, data (VCNL4020C_I2C_Bus_Read_Adr., {Low Byte Data of Ambient Light Result register #6
[86])}
3.3 Continuous Conversion Mode in Ambient Light Measurement
In the following is a detail description of the function “continuous conversion” (bit 7 of register #4)
Standard mode (bit 7 of reg #4 = 0):
In standard mode the ambient light measurement is done during a fixed time frame of 100 ms. The single measurement itself
takes actually only appr. 300 μs.
The following figures show examples of this measurement timing in standard mode using averaging function 2 and 8 as
examples for illustration (possible values up to 128).
Fig. 15 - Ambient Light Measurement with Averaging = 2;
Final Measurement Result = Average of these 2 Measurements
Fig. 16 - Ambient Light Measurement with Averaging = 8;
Final Measurement Result = Average of these 8 Measurements
Note
Independent of setting of averaging the result is available only after 100 ms.
Continuous conversion mode (bit 7 of register #4 = 1):
In continuous conversion mode the single measurements are done directly subsequent after each other.
See following examples in figure 17 and 18
Fig. 17 - Ambient Light Measurement with Averaging = 2;
using Continuous Conversion Mode
Fig. 18 - Ambient Light Measurement with Averaging = 8;
using Continuous Conversion Mode
50 ms
100 ms
Start
22315
460 μs
Start
1.5 ms22317
460 μs
Start
4.2 ms
22318
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 13 Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
PACKAGE DIMENSIONS in millimeters
Not indicated tolerances ± 0.1
1.27
1.5
0.69
2.03
4.15
4.9
2.4
0.15
0.83
0.65
0.685
2.744x0.685=
0.78 1.49 1.62
Drawing-No.: 6.550-5319
Proposed PCB Footprint
Pinning Bottom view
Pinning Top view
0.3
0.55
Anode
Emitter
SDA
INT
SCL
VDD
Cathode
Emitter
VSS
Cathode
PD
SDA
INT
SCL
VDD
Cathode
Emitter
VSS
Cathode
PD
Anode
Emitter
technical drawings
according to DIN
specifications
0.2
0.8
2.744x 0.685=
2.4
()
4.9()
0.45
0.2
0.8
0.4
0.37
0.83
1.75 0.4 1.1
0.25
0.28
0.4
0.73 0.95 0.98
0.24
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 14 Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
TAPE AND REEL DIMENSIONS in millimeters
VCNL4020C
www.vishay.com Vishay Semiconductors
Rev. 1.1, 20-Mar-18 15 Document Number: 84350
For technical questions, contact: sensorstechsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
SOLDER PROFILE
Fig. 19 - Lead (Pb)-free Reflow Solder Profile
According to J-STD-020
DRYPACK
Devices are packed in moisture barrier bags (MBB) to
prevent the products from moisture absorption during
transportation and storage. Each bag contains a desiccant.
FLOOR LIFE
Floor life (time between soldering and removing from MBB)
must not exceed the time indicated on MBB label:
Floor life: 72 h
Conditions: Tamb < 30 °C, RH < 60 %
Moisture sensitivity level 4, according to J-STD-020.
DRYING
In case of moisture absorption devices should be baked
before soldering. Conditions see J-STD-020 or label.
Devices taped on reel dry using recommended conditions
192 h at 40 °C (+ 5 °C), RH < 5 %.
240 °C
Max. 260 °C
217 °C
255 °C
19841
10
100
1000
10000
0
100
200
300
0 50 100 150 200 300
Axis Title
1st line
2nd line
2nd line
Temperature (°C)
Time (s)
50
150
250
250
245 °C
Max. 100 s
Max. 30 s
Max. 120 s
Max. ramp down 6 °C/s
Max. ramp up 3 °C/s
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 01-Jan-2021 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2021 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED