M SERIES OUTPUT MODULES
AC Modules have High Current Thyristors with 100 Amp
Surge Capability
Plug into mounting boards for 0.6" modules
Zero or Random Turn-On Available in AC Modules
4kV Optical isolation (1500 VAC Isolation for
FET DC Output Modules)
UL Recognized, CSA Certified, CE Compliant
Industry standard packaging and Color Coding
Black (AC Output) Red (DC Output)
SPECIFICATIONS
Input
5CAO-M5CAO-MrebmuN traP A M-OAC5AH M-OAC5AR M-OAC5R
Nominal Voltage [VDC] 5.0 5.0 5.0 5.0 5.0
Minimum Voltage [VDC] (2) 2.75 2.75 2.75 2.75 2.75
Maximum Voltage [VDC] 8.0 8.0 8.0 8.0 8.0
Drop-out Voltage [VDC] 1.0 1.0 1.0 1.0 1.0
Maximum Current [mA] (3) 20 20 20 20 20
Resistance [Ohms] (4) 220 220 220 220 220
Output
Nominal Line Voltage 120 VAC 240 VAC 240 VAC 240 VAC 120 VAC
Minimum Line Voltage 12 VAC 24 VAC 24 VAC 24 VAC 12 VAC
Maximum Line Voltage 140 VAC 280 VAC 280 VAC 280 VAC 140 VAC
Max Off-State Voltage (5) 400 Vpeak 600 Vpeak 600 Vpeak 600 Vpeak 400 Vpeak
Max Off-State Leakage (6) 0.1mArms 0.1mArms 0.1mArms 0.1mArms 0.1mArms
Static Off-State dv/dt (7) 200 V/usec 200 V/usec 200 V/usec 200 V/usec 200 V/usec
Maximum Rated On-State Current (8) 3.5 Arms 3.5 Arms 5.0 Arms 3.5 Arms 3.5 Arms
Minimum On-State Current 50 mArms 50 mArms 50 mArms 50 mArms 50 mArms
Max Surge Current (9) 100 Apeak 100 Apeak 100 Apeak 100 Apeak 100 Apeak
On-State Voltage Drop or Resistance (10) 1.6 V 1.6 V 1.6 V 1.6 V 1.6 V
Maximum Turn-On Time [msec] (13) 8.33 8.33 8.33 0.1 0.1
Maximum Turn-Off Time [msec] (13) 8.33 8.33 8.33 8.33 8.33
Input/Output Isolation Voltage (14) 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms
Input/Output Capacitance 8 pF 8 pF 8 pF 8 pF 8 pF
Operating Temperature Range -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C
Storage Temperature Range -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Line Frequency Range 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
Weight 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g)
Datasheet
I/O Modules
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
(1)
SPECIFICATIONS
Input
CAO-M42CAO-MrebmuN traP 24A M-ODC5 M-ODC5A M-ODC5F
Nominal Voltage [VDC] 24 24 5.0 5.0 5.0
Minimum Voltage [VDC] (2) 18 18 2.75 2.75 2.75
Maximum Voltage [VDC] 32 32 8.0 8.0 8.0
Drop-out Voltage [VDC] 1.0 1.0 1.0 1.0 1.0
Maximum Current [mA] (3) 13 13 18 18 18
Resistance [Ohms] (4) 2000 2000 250 250 250
Output
Nominal Line Voltage 120 VAC 240 VAC 5-48 VDC 5-150 VDC 5-48 VDC
Minimum Line Voltage 12 VAC 24 VAC 3.0 VDC 3.0 VDC 3.0 VDC
Maximum Line Voltage 140 VAC 280 VAC 60 VDC 250 VDC 60 VDC
Max Off-State Voltage (5) 400 Vpeak 600 Vpeak 60 VDC 250 VDC 60 VDC
Max Off-State Leakage (6) 0.1mArms 0.1mArms 10 uA 10 uA 10 uA
Static Off-State dv/dt (7) 200 V/usec 200 V/usec N/A N/A N/A
Maximum Rated On-State Current (8) 3.5 Arms 3.5 Arms 3.0 A 1.0 A 3.0 A
Minimum On-State Current 50 mArms 50 mArms 10 mA 10 mA 10 mA
Max Surge Current (9) 100 Apeak 100 Apeak 5.0 A 5.0 A 5.0 A
On-State Voltage Drop or Resistance (10) 1.6 V 1.6 V 1.5 V 1.5 V 1.5 V
Maximum Turn-On Time [msec] (13) 8.33 8.33 0.1 0.1 0.025
Maximum Turn-Off Time [msec] (13) 8.33 8.33 0.75 0.75 0.05
Input/Output Isolation Voltage (14) 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms
Input/Output Capacitance 8 pF 8 pF 8 pF 8 pF 8 pF
Operating Temperature Range -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C
Storage Temperature Range -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Line Frequency Range 47 to 63 Hz 47 to 63 Hz DC DC DC
Weight 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g)
SPECIFICATIONS
Input
5CDO-MAM5CDO-MrebmuN traP MC M-ODC5ML M-ODC24 M-ODC24A
Nominal Voltage [VDC] 5.0 5.0 5.0 24 24
Minimum Voltage [VDC] (2) 2.75 2.75 2.75 18 18
Maximum Voltage [VDC] 8.0 8.0 8.0 32 32
Drop-out Voltage [VDC] 1.0 1.0 1.0 1.0 1.0
Maximum Current [mA] (3) 18 18 18 13 13
Resistance [Ohms] (4) 250 250 250 2000 2000
Output
Nominal Line Voltage 5-150 VDC 5-90 VDC 5-48 VDC 5-48 VDC 5-150 VDC
Minimum Line Voltage 1.0 VDC 1.0 VDC 50 VDC 60 VDC 250 VDC
Maximum Line Voltage 200 VDC 100 VDC 50 VDC 60 VDC 250 VDC
Max Off-State Voltage (5) 200 VDC 100 VDC 50 VDC 60 VDC 250 VDC
Max Off-State Leakage (6) 10 uA 10 uA 10 uA 10 uA 10 uA
Static Off-State dv/dt (7) N/A N/A N/A N/A N/A
Maximum Rated On-State Current (8) 3.0 A 5.0 A 1.0 A 3.0 A 1.0 A
Minimum On-State Current 1.0 mA 1.0 mA 10 mA 10 mA 10 mA
Max Surge Current (9) 10 A 10 A 10 A 5.0 A 5.0 A
On-State Voltage Drop or Resistance (10) 0.25 Ohms 0.10 Ohms 0.05 Ohms 1.5 V 1.5 V
Maximum Turn-On Time [msec] (13) 1.0 1.0 1.0 0.1 0.1
Maximum Turn-Off Time [msec] (13) 0.05 0.05 0.05 0.75 0.75
Input/Output Isolation Voltage (14) 1500 Vrms 1500 Vrms 1500 Vrms 4000 Vrms 4000 Vrms
Input/Output Capacitance 8 pF 8 pF 8 pF 8 pF 8 pF
Operating Temperature Range -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C -30 to 80°C
Storage Temperature Range -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Line Frequency Range DC DC DC DC DC
Weight 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g)
Datasheet
I/O Modules
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
(1)
(1)
EQUIVALENT CIRCUIT DIAGRAMS / MECHANICAL SPECIFICATIONS
AGENCY APPROVALS
E46203 38595
Rev. 080916
Datasheet
I/O Modules
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
General Notes:
(1)
Specifications apply to an ambient temperature of -30 to 80°C unless otherwise noted.
Whitout external LED status indicator Add 1.7 volts for external LED if utilized.
At nominal input voltage, without external LED status indicator.
Maximum 1 minute duration for OAC modules when applied as a DC voltage rather than a peek AC voltage.
At maximum line voltage, 25°C for OAC modules, and 80°C for ODC modules.
Minimum DV/DT per EIA/NARM RS433, method RS397, DV/DT raitings do not apply to DC output models.
At 40°C derate OAC modules 58 mA/°C to 80°C derate ODC, ODCxMC and ODCxML modules 50mA/°C
to 80°C CSA rating of OAC modules is 3.0 Arms at 40°C.
At 25°C for 1 second maximum duration: 1 AC cycle for AC modules, 1 second for DC modules.
+ / - 10% at 25°C.
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
At maximum line voltage, maximum rated output current, nominal input voltage and 25°C switching speed
of OAC modules is based upon 60 Hz line frequency
At maximum rated on-state current and 25°C.
At 25°C for 1 second maximum duration.
1/3 HP at 240 VAC 1/8 HP at 120 VAC.
At 25°C for 1 second maximum duration.
Datasheet
I/O Modules
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
Disconnect all
power before
installing or
working with
this equipment.
Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
存在电击、
爆炸或电弧
闪烁危险
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
The product's side panels may be hot, allow
the product to cool before touching.
Follow proper mounting instructions including
torque values.
Do not allow liquids or foreign objects to enter
this product.
Failure to follow these instructions can result in
serious injury, or equipment damage.
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
Respecter les consignes de montage, et
notamment les couples de serrage.
Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
Le non-respect de cette directive peut entraîner,
des lésions corporelles graves ou des
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
Beachten Sie die Montageanweisungen,
Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
Respetar las instrucciones de montaje, y en
particular los pares de apretado.
No dejar que penetren líquidos o cuerpos
extraños en el producto.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
Seguire le istruzioni di montaggio corrette.
Non far entrare liquidi o oggetti estranei in questo
apparecchio.
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
材料损坏和高温外壳的危险性
产品的一侧面板可能很热,在其冷却前请
不要触碰。
遵照正确的安装说明,包括扭矩值。
请勿让液体及其他异物进入本产品。
Datasheet
I/O Modules
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated
(Pb) (Hg) (Cd) Chromium
(Cr (VI))
biphenyls
(PBB)
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
有毒有害物质或元素
名称 六价铬 多溴联苯 多溴二苯醚
(Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE)
半导体芯片
焊接点
50
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Crydom:
MODC-24A ODC15A M-OAC5AH M-OAC5AR M-OAC5R M-ODC5F M-ODC5MA M-ODC5MC M-ODC5ML M-
OAC5A M-ODC24 M-ODC5 M-OAC5 ODC15