HWS50/ME
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
Input Current (100/200VAC)(Typ) (*1)
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Designed to meet IEC61000-3-2
Voltage Fluctuations / Flicker Emissions
Designed to meet IEC61000-3-3
Power Factor (100/200VAC)(Typ) (*1)
0<Ta<70°C
-10<Ta<0°C
Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC
-10 to +70°C (-10 to +50°C:100%,+60°C:60%,+70°C:20%)
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
at 25°C and 70%RH Output - FG : 500VDC
At no operating, 10 - 55Hz (Sweep for 1min)
2
Constant, X,Y,Z 1hour each.
2
Approved by UL60601-1, EN60601-1, CSA-C22.2 No.601.1-M90
Designed to meet SEMI-F47 (200VAC Line only)
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Designed to meet IEC61000-4-2(Level 3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
26.5 x 82 x 120 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
At 100/200VAC, Ta=25°C and maximum output power.
For cases where conformance to various safety specs (UL, EN, CSA) are required,
to be described as 100 - 230VAC(50/60Hz).
Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz.
85 - 265VAC , constant load.
No load-Full load, constant input voltage.
Constant current limit and Hiccup with automatic recovery.
Not operate at over load or dead short condition for more than 30seconds.
OVP circuit will shutdown output, manual reset (Re power on).
At 100/200VAC , nominal output voltage and maximum output current.
Measured by the each measuring method of UL,EN and CSA(at 60Hz).
When using it as a patient care equipment, all outer surfaces of the equipment shall be constructed of
nonconductive material. See clause 19.5DV.2 of UL60601-1.
Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A226-01-02_).
As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90, basic insulation.