1 of 9 REV: 072406
Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device
may be simultaneously available through various sales channels. For information about device errata, click here: www.maxim-ic.com/errata.
GENERAL DESCRIPTION
The DS28CM00 is a low-cost, electronic registration
number to provide an absolutely unique identity that
can be determined with the industry standard I²C and
SMBus interface. The registration number is a
factory-lasered, 64-bit ROM that includes a unique
48-bit serial number, an 8-bit CRC, and an 8-bit
family code (70h). In SMBus mode, the DS28CM00
resets its communication interface if it detects a bus
fault condition.
APPLICATIONS
Printed Circuit Board Unique Serialization
Accessory and Peripheral Identification
Equipment Registration and License Managem ent
Network Node Identification
TYPICAL OPERATING CIRCUIT
VCC SD
A
SCL
µC
GND
VCC
SDA
SCL
DS28CM00
GND
RP RP
VCC
FEATURES
Unique, Factory-Lasere d and Tested 64-bit
Registration Number (8-bit Family Code + 48-bit
Serial Number + 8-bit CRC)
SMBus-Compatible I²C Serial Interface
Supports 100kHz and 400 kHz Communication
Speeds
5V Tolerant Interface Pins
Operating Range: 1.8V ±10% to 5V ±5%, -40°C
to +85°C
5-Pin SOT23 Package
ORDERING INFORMATION
PART TEMP RANGE PIN-PACKAGE
DS28CM00R-A00+T -40°C to +85°C SOT23-5
Tape-and-Reel
+Denotes lead-free package.
PIN CONFIGURATION
1
2
34
5SCL
GND
SDA
VCC
NC
DS28CM00
I²C/SMBus Silicon Serial Numbe
r
www.maxim-ic.com
SOT23
DS28CM00: I²C/SMBus Silicon Serial Number
2 of 9
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin Relative to Ground -0.5V, +6V
Maximum Current Into Any Pin ±20mA
Operating Temperature Range -40°C to +85°C
Junction Temperature +150°C
Storage Temperature Range -55°C to +125°C
Soldering Temperature See IPC/JEDEC J-STD-020
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond thos e indicated in the operational sections of the specifications is
not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device.
ELECTRICAL CHARACTERISTICS (-40°C to +85°C, see Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Voltage VCC 1.62 5.25 V
Standby Current ICCS Bus idle, VCC = 5.25V 3 µA
Operating Current ICCA Bus active at 400kHz, VCC
= 5.25V 200 µA
SCL, SDA Pins (Note 2) See Figure 5
VCC 2.0V -0.3 0.3 ×
VCC
LOW Level Input Voltage VIL VCC < 2.0V -0.3 0.25 ×
VCC
V
VCC 2.0V 0.7 ×
VCC VCCmax +
0.3V HIGH Level Input Voltage
(Note 3) VIH VCC < 2.0V 0.8 ×
VCC VCCmax +
0.3V
V
VCC 2.0V 0.05 ×
VCC
Hysteresis of Schmitt Trigger
Inputs (Note 4) Vhys VCC < 2.0V 0.1 ×
VCC
V
LOW Level Output Voltage at
4mA Sink Current VOL 0.4 V
VCC 2.0V 20 +
0.1Cb 250
Output Fall Time from VIhmin to
VILmax with a Bus Capacitance
from 10pF to 400pF (Notes 4,
5)
tof VCC < 2.0V 20 +
0.1Cb 450
ns
Pulse Width of Spikes that are
Suppressed by the Input Filter tSP SDA and SCL pins only
(Note 4) 50 ns
Input Current with an Input
Voltage Between 0.1VCC and
0.9VCCmax Ii (Note 6) -10 10 µA
Input Capacitance Ci (Note 4) 10 pF
VCC 2.0V 400
SCL Clock Frequency (Note 7) fSCL VCC < 2.0V 344 kHz
Bus Time-out tTIMEOUT (Note 7) 25 75 ms
Hold Time (Repeated) START
Condition. After this Period, the
First Clock Pulse is Generated. tHD:STA (Note 8) 0.6 µs
VCC 2.7V 1.3
VCC 2.0V 1.5
LOW Period of the SCL Clock
(Note 8) tLOW VCC < 2.0V 2.3 µs
HIGH Period of the SCL Clock tHIGH (Note 8) 0.6 µs
Setup Time for a Repeated
START Condition tSU:STA (Note 8) 0.6 µs
DS28CM00: I²C/SMBus Silicon Serial Number
3 of 9
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
VCC 2.7V 0.3 0.9
VCC 2.0V 0.3 1.1
Data Hold Time (Notes 9, 10) tHD:DAT VCC < 2.0V 0.3 1.7 µs
Data Setup Time tSU:DAT (Notes 8, 11) 100 ns
Setup Time for STOP Condition tSU:STO (Note 8) 0.6 µs
Bus Free Time Between a
STOP and START Condition tBUF (Note 8) 1.3 µs
Capacitive Load for Each Bus
Line Cb (Notes 4, 8) 400 pF
Note 1: Specifications at -40°C are guaranteed by design a nd characterization only and not prod uction tested.
Note 2: All values are referred to VIHmin and VILmax levels.
Note 3: The maximum specification value is guaranteed by design, not production tested.
Note 4: Not production tested. Guaranteed by de sign or characterization.
Note 5: CB = total capacitance of one bus line in pF. If mixed with HS-mode devices, faster fall-times according
to I2C-Bus Specification v2.1 are allowed.
Note 6: The DS28CM00 does not obstru ct the SDA and SCL lines if VCC is switched off.
Note 7: The minimum SCL clock frequency is limited by the bus timeout feature. If the CM bit is 1 AND SCL
stays at the same logic level or SDA stays low for this interval, the DS28CM00 behaves as though it
has sensed a STOP condit ion.
Note 8: System Requirement
Note 9: The DS28CM00 provides a hold time of at least 300ns for the SDA signal (referred to the VIHmin of the
SCL signal) to bridge the undefine d region of the falling edge of SCL.
Note 10: The maximum tHD:DAT has only to be met if the device does not stretch the low period (tLOW) of the SCL
signal.
Note 11: A Fast-mode I²C-bus device can be use d in a stand ard-mode I²C-bus system, but the requirement
tSU:DAT 250ns must then be met. This is automatically the case if the device does not stretch t he LOW
period of the SCL signal. If such a device does stret ch the LOW period of the SCL signal, it must
output the next data bit to the SDA line tr max + tSU:DAT = 1000 + 250 = 1250ns (according to the
standard-mode I²C-bus specification) before the SCL line is released.
PIN DESCRIPTION
PIN NAME FUNCTION
1 SCL
Serial interface clock input; must be tied t o VCC through a pullup resistor. 5V tolerant input
over 1.62V to 5.25V VCC range.
2 GND Ground supply for the device.
3 SDA
Serial interface bi-directional data line; must be tied t o VCC through a pullup re sistor. 5V
tolerant input/output over 1.62V to 5.25V VCC range.
4 N.C. Not Connected
5 VCC Power Suppl y Input
OVERVIEW
The DS28CM00 consists of a serial interface which provides access to a unique 64-bit Registration number and a
Control Register, as shown in the block diagram in Figure 1. The device communicates with a host processor
through its SMBus compatible I²C bus interface in standard-mode or in fast-mode. Since the network address of
the DS28CM00 is fixed, exactly one device can reside on a bus segment. The Registration Number and Control
Register are located in a linear 9-byte address space (Figure 2).
DS28CM00: I²C/SMBus Silicon Serial Number
4 of 9
Figure 1. Block Diagram
SCL
SDA ROM
Registration
Number
Control
Register
Serial
Interface
VCC
GND
Figure 2. Memory Map
ADDRESS TYPE ACCESS DESCRIPTION
00h ROM Read Device Family Code (70h)
01h ROM Read Serial Number, bits 0 to 7
02h ROM Read Serial Number, bits 8 to 15
03h ROM Read Serial Number, bits 16 to 23
04h ROM Read Serial Number, bits 24 to 31
05h ROM Read Serial Number, bits 32 to 39
06h ROM Read Serial Number, bits 40 to 47
07h ROM Read CRC of Family Code and 48-bit Serial Number
08h SRAM R/W Control Register
Unique Registration Number
Each DS28CM00 has a unique Registration Number that is 64 bits long. The registration number begins with the
family code at address 00h followed by the 48-bit serial number (LS-byte at the lower address) and ends at
address 07h with the CRC (Cyclic Redundancy Check) of the first 56 bits. This CRC is generated using the
polynomial X8 + X5 + X4 + 1. Additional information about CRCs is available in Application Note 27. The ROM
Registration Number is not related to the I²C slave addres s of the device.
Control Register
The Control Register at address 08h allows switching between I²C mode and SMBus mode. Only the LS bit of this
register, referred to as the CM bit, has a function. The other 7 bits always read 0 and cannot be changed. Whe n the
CM bit is set to 1 (power-on default), the device is in SMBus mode, which enables the bus timeout function. Setting
the CM bit to 0 puts the device in I²C mode, where the timeout function is disabled. In SMBus mode, the serial
interface times out and is internally reset if SCL is stuck (high or low) or if SDA is stuck low for the duration of
tTIMEOUT or longer. This reset turns the SDA line into an input, ensuring that the device is ready to recognize a
communication start condition.
ADDR b7 b6 b5 b4 b3 b2 b1 b0
08h 0 0 0 0 0 0 0 CM
DS28CM00: I²C/SMBus Silicon Serial Number
5 of 9
DEVICE OPERATION
Typically, the DS28CM00 is accessed after power-up to read the 64-bit Registration number, which may serve to
identify the object that the device is embedded in. Write access exists only to the Control Register. Read and write
access are controlled through the I²C/SMBus serial interface. See sectio n Re ad and Write for details.
Serial Communication Interface
General Characteristics
The serial interface uses a data line (SDA) plus a clock signal (SCL) for communication. Both SDA and SCL are
bidirectional lines, connected to a positive supply voltage through a pullup resistor. When there is no
communication, both lines are HIGH. The output stages of devices connected to the bus must have an open-drain
or open-collector to perform the wired-AND function. Data can be transferred at rates of up to 100kbps in the
Standard-mode, up to 400kbps in the F ast-mode. Th e DS28CM00 works in both modes.
A device that sends data on the bus is defined as a transmitter, and a device receiving data as a receiver. The
device that controls the communication is called a “master.” The devices that are controlled by the master are
“slaves.” The DS28CM00 is a slave device.
Slave Address/Direction Byte
To be individually accessed, each device must have a slave address that does not conflict with other devices on
the bus. The slave address to which the DS28CM00 responds is shown in Figure 3. The slave address is part of
the slave-address/direction byte. The last bit of the slave-address/direction byte (R/W) defines the data direction.
When set to a 0, subsequent data will flow from master to slave (write access mode); when set to a 1, data will flow
from slave to master (read access mo de).
Figure 3. DS28CM00 Slave Address
A6 A5 A4 A3 A2 A1 A0
1 0 1 0 0 0 0 R/W
7-Bit Slave Address
Most Signi-
ficant Bit Determines
Read or Write
I²C/SMBus Protocol
Data transfers may be initiated only when the bus is not busy. The master generates the serial clock (SCL),
controls the bus access, generates the START and STOP conditions, and determines the number of bytes
transferred between START and STOP (Figure 4). Data is transferred in bytes with the most significant bit being
transmitted first. After each byte follows an acknowledge bit to allow synchronization between master and slave.
During any data transfer, SDA must remain stable whenever the clock line is HIGH. Changes in SDA line while
SCL is high will be interpreted as a START or a STOP. The protocol is illustrated in Figure 4. For detailed timing
references see Figure 5.
DS28CM00: I²C/SMBus Silicon Serial Number
6 of 9
Figure 4. I²C/SMBus Protocol Overview
SCL
SDA
12 678
A
CK
9 912 8
MS-bit R/
W
Slave Address
ACK
bit
Acknowledgment
from Receiv er
ACK
bit
START
Condition ACK
Repeated if more byt es
are transferred
STOP Condition
Repeated START
Condition
Idle
Bus Idle or Not Busy
Both, SDA and SCL, are inactive, i. e., in their logic HIGH states.
START Condition
To initiate communication with a slave, the master has to generate a START condition. A START condition is
defined as a change in stat e of SDA from HIGH to LOW while SCL remains HIGH.
STOP Condition
To end communication with a slave, the master has to generate a STOP condition. A STOP condition is defined as
a change in state of SDA from LOW to HIGH while SCL remains HIGH.
Repeated START Condi tion
Repeated starts are commonly used for read accesses to select a specific data source or address to read from.
The master can use a repeated START condition at the end of a data transfer to immediately initiate a new data
transfer following the current one. A repeated START condition is generated the same way as a normal START
condition, but without leaving the bus idle after a STOP condition.
Data Valid
With the exception of the START and STOP condition, transitions of SDA may occur only during the LOW state of
SCL. The data on SDA must remain valid and unchanged during the entire high pulse of SCL plus the required
setup and hold time (tHD:DAT after the falling edge of SCL and tSU:DAT before the rising edge of SCL, see Figure 5).
There is one clock pulse per bit of data. Data is shifted into the receiving device during the rising edge of the SCL
pulse.
When finished with writing, the master must release the SDA line for a sufficient amount of setup time (minimum
tSU:DAT + tR in Figure 5) before the next rising edge of SCL to start reading. The slave shifts out each data bit on
SDA at the falling edge of the previous SCL pulse and the data bit is valid at the rising edge of the current SCL
pulse. The master generat es all SCL clock pulses, including tho se needed to read from a slav e.
Acknowledged
Usually, a receiving device, when addressed, is obliged to generate an acknowledge after the receipt of each byte.
The master must generate a clock pulse that is associated with this acknowledge bit. A device that acknowledges
must pull SDA LOW during the acknowledge clock pulse in such a way that SDA is stable LOW during the HIGH
period of the acknowledge-related clock pulse plus the required setup and hold time (tHD:DAT after the falling edge of
SCL and tSU:DAT before the rising edge of SCL).
DS28CM00: I²C/SMBus Silicon Serial Number
7 of 9
Not Acknowledged by Slave
A slave device may be unable to receive or transmit data, e.g., because it is busy. As a SMBus-compatible device,
the DS28CM00 will always acknowledge its slave address. However, some time later the slave may refuse to
accept data, e.g., because of an invalid memory address or access mode, e. g. attempting to write to a ROM byte.
In this case the slave device will not acknowledge any of the bytes that it refuses and will leave SDA HIGH. After a
slave has failed to acknowledge, the master should generate a repeated START condition or a STOP condition
followed by a START condition to begin a new data transfer.
Not Acknowledged by Master
At some time when receiving data, the master must signal an end of data to the slave device. To achieve this, the
master does not acknowledge the last byte that it has received from the slave. In response, the slave releases
SDA, allowing the master to generate the STOP condition.
Figure 5. I²C/SMBus Timing Diagram
SCL
SDA
STOP START
tBUF
tHD:STA
tLOW
tR
tHD:DAT
tHIGH
tSU:DAT Repeated
START
tSU:STA
tFtHD:STA tSP
tSU:STO
Spike
Suppression
NOTE: Timing is referenced to VILMAX and VIHMIN.
Read and Write
The DS28CM00 behaves like an I²C memory device with an 9-byte memory map (Figure 2). The memory consists
of 8 bytes ROM and one byte SRAM, i. e., the Control Register. The ROM data cannot be changed.
To write to the DS28CM00, the master must access the device in write access mode, i.e., the slave address must
be sent with the direction bit set to 0. The next byte to be sent in write access mode is an address byte to set the
address pointer to a specific location. The DS28CM00 acknowledges any address between 00h and 08h. Write
attempts to the ROM are ignored and data received for these addresses is not acknowledged. However, the
address pointer increments after every full data byte transmitted by the master and rolls over from 08h to 00h after
a full data byte is written to address 08h.
To read from the DS28CM00, the master must access the device in read access mode, i.e., the slave address
must be sent with the direction bit set to 1. The address pointer determines the location from which the master will
start reading. The pointer is set when the DS28CM00 is accessed in write access mode, as described above. The
power-on default of the pointer is 00h. When reading from the device, the address pointer increments with every
data byte read. When the end of the memory is reached (address 08h), the address pointer wraps around to 00h.
To read from an arbitrary address, the master must first access the DS28CM00 in write access mode and specify a
new memory address. The address pointer remains unchanged if the device resets its communication interface
due to a bus timeout in SMBus mode.
DS28CM00: I²C/SMBus Silicon Serial Number
8 of 9
I²C CommunicationLegend
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
S START Condition A Acknowledged
AD,0 Select DS28CM00 for Write Access A\ Not Acknowledged
AD,1 Select DS28CM00 for Read Access <byte> Transfer of One Byte
Sr Repeated START Condition VMA Valid Memory Address (00 h to 08h)
P STOP Condition IMA Invalid Memory Address
Command-Specific CommunicationColor-Codes
Master-to-Slave Slave-to-Master
Communication Examples
Write to Control Register (addre ss 08)
S AD,0 A 08h A <byte> A P
Write to ROM Address (excludes address 08)
S AD,0 A VMA A <byte> A\ P
Write to invalid address (>08)
S AD,0 A IMA A\ P
Read
S AD,0 A VMA A Sr AD,1 A <byte> A <byte> A\ P
Application Information
SDA and SCL Pullup Resistors
SDA is an open-drain output on the DS28CM00 that requires a pullup resistor (Figure 6) to realize high logic levels.
Because the DS28CM00 uses SCL only as input (no clock stretching) the master can drive SCL either through an
open-drain/collector output with a pullup resistor or a push-pull output.
Pullup Resistor RP Sizing
According to the I²C specification, a slave device must be able to sink at least 3mA at a VOL of 0.4V. The SMBus
specification requires a current sink capability of 4mA at 0.4V. The DS28CM00 can sink at least 4mA at 0.4V VOL
over its entire operating voltage range. This DC characteristic determines the minimum value of the pullup resistor:
Rpmin = (VCC - 0.4V)/4mA. With a maximum operating voltage of 5.25V, the minimum value for the pullup resistor
is 1.2kΩ. The "Minimum RP" line in Figure 7 shows how the minimum pullup resistor changes with the operating
(pullup) voltage.
last byte
one or
more bytes
data is not accepted
address is not accepted
Set address pointer
DS28CM00: I²C/SMBus Silicon Serial Number
9 of 9
Figure 6. Application Schematic
VCC SD
A
SCL
µC
GND
VCC
SDA
SCL
DS28CM00
GND
RPRP
VCC
To additional
devices
For I²C systems, the rise time and fall time are measured from 30% to 70% of the pullup voltage. The maximum
bus capacitance CB is 400pF. The maximum rise time must not exceed 300ns. Assuming maximum rise time, the
maximum resistor value at any given capacitance CB is calculated as: RPMAX = 300ns/(CB*ln(7/3)). For a bus
capacitance of 400pF the maximum pullup resistor would be 885Ω.
Since a 885Ω pullup resistor, as would be required to meet the rise time specification and 400pF bus capacitance,
is lower than RPMIN at 5.25V, a different approach is necessary. The "Max. Load…" line in Figure 7 is generated by
first calculating the minimum pullup resistor at any given operating voltage ("Minimum RP" line) and then calculating
the respective bus capacitance that yields a ri se time of 300ns.
Only for pullup voltages of 4V and lower can the maximum permissible bus capacitance of 400pF be maintained. A
reduced bus capacitance of 300pF is acceptable for the entire operating voltage range. The corresponding pullup
resistor value at the voltage is indicated by the "Minimum RP" line.
Figure 7. I²C Fast Speed Pullup Resistor Selection Chart
0
200
400
600
800
1000
1200
1.5 2 2.5 3 3.5 4 4.5 5
Pull-up Volta ge
Minimum Rp (Ohms)
0
100
200
300
400
500
600
Load (pF)
"M inimum Rp" M ax. Load at Min . Rp fas t m ode
PACKAGE INFORMATION
(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to
www.maxim-ic.com/DallasPackInfo.)
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Maxim Integrated:
DS28CM00R-A00+T DS28CM00R-A00+U