Series XV Single Output to 30A 420 Vac No Heat Sink, Hybrid Relay Part Number Description XV46D30K 30A, 420 Vac Part Number Explanation XV 46 D 30 K NOTES 1) Line Voltage (nominal): 46 = 420 Vac 2) Switch Type: D = Zero-cross turn-on 3) Control Range: K = 20-30 Vdc, *C = 12 Vdc also available MECHANICAL SPECIFICATION 1.10 (28) 1.87 (47.6) 2.41 (61.3) .27 (6.8) 1.77 (45) 1.70 (43.2) WEIGHT: 5.64 oz (160g) O.19 (O4.7) .35 (9) M4 FEATURES/BENEFITS * Industry standard package * Combines the best of solid-state and electromechanical relays * Tight zero-cross window for low EMI * Control LED * Internal output protection * High immunity to surges DESCRIPTION The Series XV relay combines the best of solid-state and electromechanical technology. The relay is designed in a touch-proof hockey-puck package. The XV relay switches current up to 30A without a heat sink. Visual control status is provided as a standard. Elimination of the heat sink conserves space and makes the XV ideal for numerous applications. M3.5 1.75 (44.5) 1.00 (25.4) Figure 1 - XV relay; dimensions in inches (mm) INPUT (CONTROL) SPECIFICATION Min Max Units Control Range* 20 30 Vdc Input Current Range 31 41 mAdc Must Turn-Off Voltage 10 Vdc Input Resistance (Typical) 640 Ohms Reverse Voltage Protection 30 Vdc Control Frequency 1 Hz APPLICATIONS * Interface applications * Heating Control * Light/Lamp control * Contactor driver * Fan speed control * HVAC controls APPROVALS Model XV46D30K is UL recognized. UL File Number: E128555. CONTROL CHARACTERISTIC TYPICAL APPLICATION 45 A1+ t3 Vc SSR Supply t1 A1- T1 t2 EMR VL L1 LED Input Current (mA) 40 35 30 25 20 15 10 Load Figure 2 - XV relay 5 0 0 5 10 15 20 25 30 35 Control Voltage (V) Figure 3 - XV relay (c) 2003 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com XV 1 XV\032003\Q1 Series XV OUTPUT (LOAD) SPECIFICATION Max 12 420 Vrms 800 Vpeak Peak Voltage Load Current Range 0.1 Motor Load Current Unit 30 Arms 7.5 Arms 250 200 Apeak Operating Range SURGE CURRENT Min Maximum Surge Current Rating (Non-Repetitive) (See Figure 4) 240 Apeak 0.3 V Zero-Cross Window (Typical) 12 V Off-State Leakage Current (60Hz) 2 mA Turn-On Time (60Hz) 12 ms Turn-Off Time (60Hz) 20 ms Off-State dv/dt 500 V/s Maximum di/dt (Non-repetitive) 50 A/s Operating Frequency 440 Hz 288 2 40 I t for fuse matching (<8.3ms) 100 50 On-State Voltage Drop 2 150 0 1 10 100 1000 Number of Cycles Figure 4 - XV relay LIFETIME EXPECTANCY 5 At maximum rated current (Resistive load) AS ENVIRONMENTAL SPECIFICATION Min Max Unit Operating Temperature -40 90 C Storage Temperature -40 100 C 4000 Vrms 4000 V Input-Output Isolation Output-Case Isolation Life Expectancy See Figure 5 10 6 Operations 4 3 2 1 0 100 200 300 400 500 Load Voltage (V) Figure 5 - XV relay NOTES: 1. Electrical Specifications at 25C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom options, contact factory. XV 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2003 TELEDYNE RELAYS XV\032003\Q1