Absolute Maximum Ratings
Parameter Minimum Nominal Maximum Units Notes
Storage Temperature -55 - 125 °C
Supply Voltage (Vcc) -0.5 - 13.5 Vdc
Control Voltage (Vc) -0.5 - 7.0 Vdc
Operating Supply Voltage 3.3 Vdc (Vcc) 3.13 3.30 3.47 Vdc
Operating Supply Voltage 5.0 Vdc (Vcc) 4.75 5.00 5.25 Vdc
Operating Supply Voltage 12 Vdc (Vcc) 11.40 12.00 12.60 Vdc
Operating Specifications
Parameter Minimum Nominal Maximum Units Notes
Center Frequency: (Fo) 5.0 - 40.0 MHz
Operating Temperature Range:
Temperature Code 5 0 - 70 °C
Temperature Code 6 -40 - 85 °C
Temperature Code 7 -20 - 70 °C
Temperature Code 8 -40 - 70 °C
Frequency Calibration: -0.1 - 0.1 ppm @ 25°C
Frequency Stability vs. Change in Temperature:
Stability Code 06 -3.0 - 3.0 ppb 1
Stability Code 10 -5.0 - 5.0 ppb 1
Stability Code 20 -10.0 - 10.0 ppb 1
Stability Code 50 -25.0 - 25.0 ppb 1
Frequency Stability vs. Load -5.0 - 5.0 ppb ±5%
Frequency Stability vs. Voltage -5.0 - 5.0 ppb ±5%
Aging: Daily:
5 MHz to 20 MHz -1.0 - 1.0 ppb/day 2
>20 MHz to 40 MHz -2.0 - 2.0 ppb/day 2
Aging: First Year:
5 MHz to 20 MHz -50 - 50 ppb
>20 MHz to 40 MHz -100 - 100 ppb
Lifetime Tolerance: (20 Years)
5 MHz to 20 MHz- -300 - 300 ppb 3
>20 MHz to 40 MHz -500 - 500 ppb 3
Supply Voltage: (Vcc)
Voltage Code 03 3.13 3.30 3.47 Vdc 4
Voltage Code 05 4.75 5.00 5.25 Vdc 4
Voltage Code 12 11.40 12.00 12.60 Vdc 4
Power Consumption: Turn-On
0 to 70°C Models - - 3.00 W 5
-20 to 70°C Models - - 3.20 W 5
-20 to 75°C Models - - 3.30 W 5
-40 to 85°C Models - - 3.80 W 5
Power Consumption: Steady State @ 25°C
0 to 70°C Models - - 1.10 W 5
-20 to 70°C Models - - 1.10 W 5
-20 to 75°C Models - - 1.20 W 5
-40 to 85°C Models - - 1.50 W 5
Phase Jitter: (BW: 10 Hz to Fo/2)
Models with Fo: 5 MHz to 20 MHz - - 1.0 ps rms
Models with Fo: >20 MHz to 40 MHz - - 2.0 ps rms
Short Term Allan Deviation (1s) - 1.0E-11 - rms
Start-Up Time: - - 500 ms
Warm Up Time @ 25°C: - - 5 minutes 6
Bulletin Cx193
Page 2 of 5
Revision 11
Date 13 May 2013
Notes:
1. Frequency stability vs. change in temperature [±(Fmax-Fmin)/(2*Fo)].
2. At time of shipment after 48 hours of operation.
3. Inclusive of calibration, operating temperature, supply voltage change, load change and 20 years aging.
4. Supply voltage must reach Vcc levels monotonically within a ramp-up time of <12 ms.
5. Measured with Vcc = Nominal, in calm air.
6. Measured @ 25°C, within 5 minutes, referenced one hour after turn-on.
7. To ensure proper operation of OCVCXO's the control voltage input must be biased the nominal control voltage. Failure to bias
the Vc input will cause an unstable output condition.
Absolute Ratings: Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress
ratings only. The functional operation of the device at those or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to conditions outside the "recommended operating conditions" for any extended period of time may adversely
impact device reliability and result in failures not covered by warranty.