136
MEDER electronic
www.meder.com
CRF Series
7 GHz High Frequency Reed Relay
for 50 Ω Impedance
RELAY DATA
All Data at 20° C Switch Model →
Contact Form →
Contact 80
Form A
Contact Ratings Conditions Min. Typ. Max. Units
Contact Ratings Any DC combination of V & A not to
exceed their individual max.‘s. 10 W
Switching Voltage DC or peak AC 170 V
Switching Current DC or peak AC 0.5 A
Carry Current DC or peak AC 0.5 A
Bulk Resistance Through all plated material on
substrate 200 350 mΩ
Static Contact Resistance w/ 0.5 V & 50 mA 75 100 mΩ
Dynamic Contact Resistance Measured w/ 0.5 V & 50mA 100 150 mΩ
Insulation Resistance
(100 Volts applied)
Across Contact
Contact to coil and shield
1010
1013
1012
1014 Ω
Breakdown Voltage Across Contact
Coil to contact
210
1500 VDC
Operate Time incl. Bounce Measured w/ nominal voltage 0.1 ms
Release Time No coil suppression 0.02 ms
Capacitance (@ 10 kHz) Across Contact
Contact to coil and shield
0.1
0.7 pF
Life Expectancies
Switching 5 V - 10mA DC <10 pF stray cap. 1000 106
Cycles
For other load requirements, see the life test section on P. 120.
Environmental Data
Shock Resistance 1/2 Sine wave duration for 11 ms 50 g
Vibration Resistance From 10 - 2000 Hz 10 g
Ambient Temperature 10 oC/ minute max. allowable -40 125 oC
Storage Temperature 10 oC/ minute max. allowable -55 125 oC
Soldering Temperature 5 sec. dwell 260 oC
Material of Case Themoset / Ceramic
Material of pads Au plated