Table I. Evaluation Board Configuration Options
Component Function Default Condition
TP1, TP2 Supply and Ground Vector Pins Not Applicable
SW1 Device Enable. When in position A, the ENBL SW1 = A
pin is connected to +V
S
and the AD8314 is in
operating mode. In Position B, the ENBL pin is
grounded, putting the device in power-down mode.
R1, R2 Input Interface. The 52.3 W resistor in position R2 = 52.3 W (Size 0603)
R2 combines with the AD8314’s internal input R1 = 0 W (Size 0402)
impedance to give a broadband input impedance
of around 50 W. A reactive match can be imple-
mented by replacing R2 with an inductor and
R1 (0 W) with a capacitor. Note that the AD8314’s
RF input is internally ac-coupled.
R3, R4, C2, R5, R6, C3 Output Interface. R4, C2, R6, and C3 can be R4 = C2 = R6 = C3 = Open (Size 0603)
used to check the response of V_UP and V_DN R3 = R5 = 0 W (Size 0603)
to capacitive and resistive loading. R3/R4 and
R5/R6 can be used to reduce the slope of V_UP
and V_DN.
C1, R9 Power Supply Decoupling. The nominal supply C1 = 0.1 mF (Size 0603)
decoupling consists of a 0.1 mF capacitor (C1). A R9 = 0 W (Size 0603)
series inductor or small resistor can be placed in
R9 for additional decoupling.
C4 Filter Capacitor. The response time of V_UP C4 = Open (Size 0603)
and V_DN can be modified by placing a capacitor
between FLTR (Pin 4) and V_UP.
R7, R8 Slope Adjust. By installing resistors in R7 and R8, R7 = 0 W (Size 0603)
the nominal slope of 20 mV/dB can be increased. R8 = Open (Size 0603)
See Slope Adjust section of the AD8314 data sheet
for more details.
LK1 Measurement/Controller Mode. LK1 shorts LK1 = Installed
V_UP to VSET, placing the AD8314 in
measurement mode. Removing LK1 places
the AD8314 in controller mode.
Figure 2. Layout of Component Side (MSOP) Figure 3. Silkscreen of Component Side (MSOP)