AEH Half-brick Series Te c h n i c a l R e f e r e n c e N o t e s 48V Input, 2.5V Output 50-150W DC-DC Converter (Rev01) -1TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 Publishing Date: 20020702 AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Introduction Design Features The AEH series comes in a industry standard ! High Efficiency half-brick package of 2.4" x 2.28" x 0.5" and ! High power density ! Low output noise ! Metal baseplate available with 2:1 input range of 36V-75V ( and ! CNT function 36V-72V is for 5V output ). Outputs of 2.5V, ! Remote sense 3.3V, and 5V are fully isolated from input and ! Trim function ! Input under-voltage lockout ! Output short circuit protection put. ! Output current limiting Designed using a synchronous rectification ! Output over-voltage protection topology, AEH series incorporates simple struc- ! Overtemperature protection ! High input-output isolation voltage footprint, and incorporates the super high efficiency up to 87% in 2.5V output and high power density up to 54.8W/in3. The AEH series is the isolation voltage is 1500Vdc. The typical efficiencies are 90% for the 5V output, 89% for the 3V output, and 87% for the 2.5V out- ture, good electrical performance and high reliability. Standard features include input LVP, OCP, output OVP, short circuit protection, and over-temperature protection. Using aluminum Options based plate, the maximum case temperature can reach 100 C without derating. The AEH series is designed to meet CISPR22, FCC Class A, UL, TUV, and CSA certifications. TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 ! Heat sink available for extended operation. ! Choice of CNT logic configuration. Asia 852-2437-9662 852-2402-4426 -2www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Typical Application Fuse* +Vin +Sense +Vout CNT Vin Trim Case C1 C3 C4 C2 Load -Vout -Vin -Sense Fuse*: Use external fuse ( fast blow type ) for each unit. 50W rated output : 5A fuse 75W rated output : 7.5A fuse 100W rated output : 10A fuse 150W rated output : 20A fuse C1: Recommended input capacitor C1 -40 C~ +100 C: m 47F/100V electrolytic capacitor. C2: Recommended output capacitor C2 0C~ +100C: one 2200 F/ 6.3V electrolytic capacitor Below 0C: use 1 X 220F tantalum capacitor parallel with a 2200F/ 6.3V electrolytic capacitor C3: Recommended 4700pF/2000V C4: Recommended 1F/10V TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -3www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Block Diagram +Vin +Vout -Vin -Vout +Sense Trim -Sense CNT Ordering Information TEL: FAX: Model Number Input Voltage CNT Logic Output Current Ripple (mV rms) Noise (mV pp) AEH10G48N AEH10G48 AEH15G48N AEH15G48 AEH20G48N AEH20G48 AEH30G48N AEH30G48 36-75V 36-75V 36-75V 36-75V 36-75V 36-75V 36-75V 36-75V Negative Positive Negative Positive Negative Positive Negative Positive 10A 10A 15A 15A 20A 20A 30A 30A 40 40 40 40 40 40 40 40 150 150 150 150 150 150 150 150 USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 Efficiency min typ 84% 84% 83% 83% 85% 85% 83% 83% 86% 86% 85% 85% 87% 87% 85% 85% -4www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Absolute Maximum Rating Characteristic Min Typ Max Units Input Voltage(continuous) -0.3 80 Vdc Input Voltage(peak/surge) -0.3 100 Vdc Operating temperature -40 100* C Storage temperature -55 125 C Notes 100ms non-repetitive *: case temperture Input Characteristics Characteristic Min Typ Max Units Input Voltage Range 36 48 75 Vdc 25 50 mAp-p Input Reflected Current Turn-off Input Voltage 30 33 35 V Turn-on Input Voltage 31 34 36 V 15 25 ms Typ Max Units 15 Vdc 1.2 Vdc 2 mA Turn On Time Notes CNT Function Characteristic Logic High Min 3 Logic Low Control Current Notes General Specifications Characteristic MTBF Min Typ 2080 Units Notes k Hrs Bellcore TR332, Tc=30C Isolation 1500 Vdc Pin solder temperature 260 C wave solder < 10 s 5 s iron temperature 425C Hand Soldering Time Weight TEL: FAX: Max USA 1-760-930-4600 1-760-930-0698 70 Europe 44-(0)1384-842-211 44-(0)1384-843-355 grams Asia 852-2437-9662 852-2402-4426 -5www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W AEH10G48(N) Output Characteristics Characteristic Min Typ Max Units Power 25 W Output Current 10 A Output Setpoint Voltage 2.475 Notes 2.5 2.525 Vdc Vin=48V, Io=10A Line Regulation 0.02 0.2 %Vo Vin=36~75V, Io=10A Load Regulation 0.1 0.5 %Vo Io=0~10A, Vin=48V 1.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s 1.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s Dynamic Response 50-75% load 50-25% load Current Limit Threshold 11 12.5 Short Circuit Current A 17 A 86 % Efficiency 84 Trim Range 90 110 %Vo 3 3.9 V 10 %Vo 0.02 %Vo/C Over Voltage Protection Setpoint Sense Compensation Temperature Regulation TEL: FAX: 14 Vin=48V, Io=10A 5%Vo each leg Ripple (rms) 20 40 mV ( 0 to 20MHz Bandwidth ) Noise (p-p) 100 150 mV ( 0 to 20MHz Bandwidth ) Over Temperature Protection 105 C Switching Frequency 180 kHz USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -6www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W AEH15G48(N) Output Characteristics Characteristic Min Power Typ Units 37.5 W 15 A Output Current Output Setpoint Voltage Max 2.475 Notes 2.5 2.525 Vdc Vin=48V, Io=15A Line Regulation 0.02 0.2 %Vo Vin=36~75V, Io=15A Load Regulation 0.1 0.5 %Vo Io=0~15A, Vin=48V 1.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s 1.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s Dynamic Response 50-75% load 50-25% load Current Limit Threshold 16.5 19 Short Circuit Current A 20 A 85 % Efficiency 83 Trim Range 90 110 %Vo 3 3.9 V 10 %Vo 0.02 %Vo/C Over Voltage Protection Setpoint Sense Compensation Temperature Regulation TEL: FAX: 21 Vin=48V, Io=15A 5%Vo each leg Ripple (rms) 20 40 mV ( 0 to 20MHz Bandwidth ) Noise (p-p) 100 150 mV ( 0 to 20MHz Bandwidth ) Over Temperature Protection 105 C Switching Frequency 180 kHz USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -7www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W AEH20G48(N) Output Characteristics Characteristic Min Typ Max Units Power 50 W Output Current 20 A Output Setpoint Voltage 2.475 Notes 2.5 2.525 Vdc Vin=48V, Io=20A Line Regulation 0.02 0.2 %Vo Vin=36~75V, Io=20A Load Regulation 0.1 0.5 %Vo Io=0~20A, Vin=48V 1.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s 2.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s Dynamic Response 50-75% load 50-25% load Current Limit Threshold 22 25 Short Circuit Current A 30 A 87 % Efficiency 85 Trim Range 90 110 %Vo 3 3.9 V Sense Compensation 10 %Vo Temperature Regulation 0.02 %Vo/C 20 40 mV ( 0 to 20MHz Bandwidth ) Noise (pp) 100 150 mV ( 0 to 20MHz Bandwidth ) Over Temperature Protection 105 C Switching Frequency 180 kHz Over Voltage Protection Setpoint Ripple (rms) TEL: FAX: 28 USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 Vin=48V, Io=20A 5%Vo each leg -8www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W AEH30G48(N) Output Characteristics Characteristic Min Typ Max Units Power 75 W Output Current 30 A Output Setpoint Voltage 2.475 Notes 2.5 2.525 Vdc Vin=48V, Io=30A Line Regulation 0.02 0.2 %Vo Vin=36~75V, Io=30A Load Regulation 0.1 0.5 %Vo Io=0~30A, Vin=48V 2.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s 2.5 %Vo Ta=25C, di/dt = 1A/10s 100 s Ta=25C, di/dt = 1A/10s Dynamic Response 50-75% load 50-25% load Current Limit Threshold 32 36 Short Circuit Current A 40 A 85 % Efficiency 83 Trim Range 90 110 %Vo 3 3.9 V Sense Compensation 10 %Vo Temperature Regulation 0.02 %Vo/C 20 40 mV ( 0 to 20MHz Bandwidth ) Noise (pp) 100 150 mV ( 0 to 20MHz Bandwidth ) Over Temperature Protection 105 C Switching Frequency 180 kHz Over Voltage Protection Setpoint Ripple (rms) TEL: FAX: 40 USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 Vin=48V, Io=30A 5%Vo each leg -9www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves (at 25 C ) Typical Efficiency AEH15G48N 90 90 85 86 Efficiency (%) Efficiency (%) Typical Efficiency AEH10G48N 80 75 70 82 78 Vin=36V 65 Vin=48V Vin=75V 60 0 10 20 30 40 50 60 70 80 90 Vin=36V 74 Vin=48V Vin=75V 70 0 100 10 20 30 50 60 70 80 90 86 86 Efficiency (%) 90 82 78 Vin=36V 74 82 78 Vin=36V 74 Vin=48V Vin=48V Vin=75V 70 10 20 30 40 50 60 70 80 90 100 Vin=75V 70 0 USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 10 20 30 40 50 60 70 80 90 100 %Iomax %Iomax TEL: FAX: 100 Typical Efficiency AEH30G48N Typical Efficiency AEH20G48N 0 90 %Iomax %Iomax Efficiency (%) 40 Asia 852-2437-9662 852-2402-4426 -10www.astec.com AEH High Efficiency Series Half-Brick Power Converters 3 6 V D C t o 7 5 V D C I n p u t , 2 . 5 V O u t p u t , 5 0 - 1 5 0 Wa t t Characteristic Curves Typical Output Overcurrent Characteristics AEH15G48N 2.8 2.8 2.4 2.4 Output Voltage (volts) Output Voltage (volts) Typical Output Overcurrent Characteristics AEH10G48N (at 25 C ) 2 Vin=36V 1.6 Vin=48V 1.2 Vin=75V 0.8 0.4 2 1.6 Vin=36V Vin=48V 1.2 Vin=75V 0.8 0.4 0 3 6 9 12 15 0 Output Curent (amps) 2.4 2.4 Output Voltage (volts) Output Voltage (volts) 2.8 2 Vin=36V Vin=48V Vin=75V 0.8 12 15 18 21 2 Vin=36V 1.6 Vin=48V 1.2 Vin=75V 0.8 0.4 0.4 0 4 8 12 16 20 24 28 0 Output Curent (amps) TEL: FAX: 9 Typical Output Overcurrent Characteristics AEH30G48N 2.8 1.2 6 Output Curent (amps) Typical Output Overcurrent Characteristics AEH20G48N 1.6 3 USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 8 16 24 32 40 Output Curent (amps) Asia 852-2437-9662 852-2402-4426 -11www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves (at 25 C ) Typical Input-Output Characteristics AEH10G48N Typical Input-Output Characteristics AEH15G48N 1.5 Input Current (amps) Input Current (amps) 1 0.8 0.6 0.4 0.2 1.2 0.9 0.6 0.3 0 0 0 20 40 60 0 80 20 Input Voltage (volts) 80 Typical Input-Output Characteristics AEH30G48N 3 Input Current (amps) 2 Input Current (amps) 60 Input Voltage (volts) Typical Input-Output Characteristics AEH20G48N 1.6 1.2 0.8 0.4 0 2.4 1.8 1.2 0.6 0 0 20 40 60 80 0 Input Voltage (volts) TEL: FAX: 40 USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 20 40 60 80 Input Voltage (volts) Asia 852-2437-9662 852-2402-4426 -12www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W T ransient response TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Transient Response to Step Load Change from 25%-50%-25%Iomax AEH10G48N Typical Transient Response to Step Load Change from 25%-50%-25%Iomax AEH15G48N Typical Transient Response to Step Load Change from 25%-50%-25%Iomax AEH20G48N Typical Transient Response to Step Load Change from 25%-50%-25%Iomax AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -13www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W T ransient response TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Transient Response to Step Load Change from 50%-75%-50%Iomax AEH10G48N Typical Transient Response to Step Load Change from 50%-75%-50%Iomax AEH15G48N Typical Transient Response to Step Load Change from 50%-75%-50%Iomax AEH20G48N Typical Transient Response to Step Load Change from 50%-75%-50%Iomax AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -14www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Start-Up from Power On AEH10G48N Typical Start-Up from Power On AEH15G48N Typical Start-Up from Power On AEH20G48N Typical Start-Up from Power On AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -15www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Shut-down from Power Off AEH10G48N Typical Shut-down from Power Off AEH15G48N Typical Shut-down from Power Off AEH20G48N Typical Shut-down from Power Off AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -16www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Start-Up Transient with CNT Control AEH10G48N Typical Start-Up Transient with CNT Control AEH15G48N Typical Start-Up Transient with CNT Control AEH20G48N Typical Start-Up Transient CNT Control AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -17www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Shut-down Transient with CNT Control AEH10G48N Typical Shut-down Transient with CNT Control AEH15G48N Typical Shut-down Transient with CNT Control AEH20G48N Typical Shut-down Transient with CNT Control AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -18www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves TEL: FAX: (48V rated input voltage, full load, at 25 C) Typical Output Ripple Voltage AEH10G48N Typical Output Ripple Voltage AEH15G48N Typical Output Ripple Voltage AEH20G48N Typical Output Ripple Voltage AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -19www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Characteristic Curves TEL: FAX: (48V rated input voltage, full load, at 25 C) Overvoltage Protection AEH10G48N Overvoltage Protection AEH15G48N Overvoltage Protection AEH20G48N Overvoltage Protection AEH30G48N USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -20www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Pins The +Vin and -Vin input connection pins are located as shown in Figure 1. AEH converters have a 2:1 input voltage range and 2.5V output converters can accept 36-75 Vdc. Care should be taken to avoid applying reverse polarity to the input which can damage the converter. -Vin -Vout Case -Sense CNT +Sense +Vin +Vout Trim Component-side footprint Standard safety agency regulations require input fusing. Recommended fuse ratings for the AEH Series are shown in Table 1. Input Reverse Voltage Protection Under installation and cabling conditions where reverse polarity across the input may occur, reverse polarity protection is recommended. Protection can easily be provided as shown in Figure 2. In both cases the diode rating is determined by the power of the converter. Diodes should be rated at 20A/100V for 150W, 10A/100V for 100W, 7.5A/100V for 75W, and 5A/100V for 50W. Placing the diode across the inputs rather than in-line with the input offers an advantage in that the diode only conducts in a reverse polarity condition, which increases circuit efficiency and thermal performance. Fig.1 Pin Location Input Characteristic +Vin +Vin -Vin -Vin Fig.2 Reverse Polarity Protection Circuits Fusing The AEH power module has no internal fuse. An external fuse must always be employed! To meet international safety requirements, a 250 Volt rated fuse should be used. If one of the input lines is connected to chassis ground, then the fuse must be placed in the other input line. Table 1 Rated Pout 50 Watt 75 Watt 100 Watt 150 Watt TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Fuse Rating 5A 7.5A 10A 20A Europe 44-(0)1384-842-211 44-(0)1384-843-355 Input Undervoltage Protection The AEH is protected against undervoltage on the input. If the input voltage drops below the acceptable range, the converter will shut down. It will automatically restart when the undervoltage condition is removed. Input Filter Input filters are included in the converters to help achieve standard system emissions certifications. Some users however, may find that additional input filtering is necessary. The AEH 2.5V output series has an internal switching frequency of 180kHz so a high frequency capacitor mounted close to the input terminals pro- Asia 852-2437-9662 852-2402-4426 -21www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W duces the best results. To reduce reflected noise, a capacitor can be added across the input as shown in Figure 3, forming a filter. A 47F/100V electrolytic capacitor is recommended for C1. +Vin C1 -Vin 3V to the CNT pin will enable the output, and applying a voltage less than 1.2V will disable it. Positive logic, device code suffix " P " . Negative logic, device code suffix nothing is the factory-preferred. If the CNT pin is left open, the converter will default to " control off " operation in negative logic, but default to " control on " in positive logic. The maximum voltage that can be applied to the CNT pin is 15V. Fig.3 Ripple Rejection Input Filter CNT For conditions where EMI is a concern, a different input filter can be used. Figure 4 shows an input filter designed to reduce EMI effects. L1 is a 5mH common mode choke. -Vin Fig.5 Simple Control CNT 2200uF/16V 0.33uF 1uF 1uF -Vin 1000p Case 470u 1u Fig.6 Transistor Control L1 0.33uF -Vin CNT 1000p 100pF -Vin Fig.4 EMI Reduction Input Filter Fig.7 Isolated Control CNT When a filter inductor is connected in series with the power converter input, an input capacitor C1 should be added. An input capacitor C1 should also be used when the input wiring is long, since the wiring can act as an inductor. Failure to use an input capacitor under these conditions can produce large input voltage spikes and an unstable output. CNT Function Two CNT options are available. Negative logic applying a voltage less than 1.2V to the CNT pin will enable the output, and applying a voltage greater than 3V will disable it. Positive logic applying a voltage larger than TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 -Vin Fig.8 Relay Control Input-Output Characteristic Safety Consideration For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL1950, CSA C22.2 No. 950-95, and EN60950. The Asia 852-2437-9662 852-2402-4426 -22www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W input-to-output 1500VDC isolation is an operational insulation. The DC/DC power module should be installed in end-use equipment, in compliance with the requirements of the ultimate application, and is intended to be supplied by an isolated secondary circuit. When the supply to the DC/DC power module meets all the requirements for SELV(<60Vdc), the output is considered to remain within SELV limits (level 3). If connected to a 60Vdc power system, double or reinforced insulation must be provided in the power supply that isolates the input from any hazardous voltages, including the ac mains. One Vin pin and one Vout pin are to be grounded or both the input and output pins are to be kept floating. Single fault testing in the power supply must be performed in combination with the DC/DC power module to demonstrate that the output meets the requirement for SELV. The input pins of the module are not operator accessible. Note: Do not ground either of the input pins of the module, without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pin and ground. Case Grounding For proper operation of the module, the case or baseplate of the AEH module does not require a connection to a chassis ground. If the AEH module is not in a metallic enclosure in a system, it may be advisable to directly ground the case to reduce electric field emissions. Leaving the case floating can help to reduce magnetic field radiation from common mode noise currents. If the case has to be grounded for safety or other reasons, an inductor can be connected to chassis at DC and AC line frequencies, but be left floating at switching frequencies. Under this condition, the safety requirements are met and the emissions are minimized. TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Output Characteristics Minimum Load Requirement There is no minimum load required for the AEH series modules. Remote Sensing The AEH converter can remotely sense both lines of its output which moves the effective output voltage regulation point from the output of the unit to the point of connection of the remote sense pins. This feature automatically adjusts the real output voltage of the AEH in order to compensate for voltage drops in distribution and maintain a regulated voltage at the point of load. When the converter is supporting loads far away, or is used with undersized cabling, significant voltage drop can occur at the load. The best defense against such drops is to locate the load close to the converter and to ensure adequately sized cabling is used. When this is not possible, the converter can compensate for a drop of up to 0.5V, through use of the sense leads. When used, the + and - Sense leads should be connected from the converter to the point of load as shown in Figure 9 using twisted pair wire. The converter will then regulate its output voltage at the point where the leads are connected. Care should be taken not to reverse the sense leads. If reversed, the converter will trigger OVP protection and turn off. When not +Vout +Sense +S Twisted Pair Load -Sense -S -Vout Fig.9 Sense Connections Asia 852-2437-9662 852-2402-4426 -23www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W used, the +Sense lead must be connected with +Vo, and -Sense with -Vo. Also note that the output voltage and the remote sense voltage offset must be less than the minimum overvoltage trip point. Note that at elevated output voltages the maximum power rating of the module remains the same, and the output current capability will decrease correspondingly. Output Over-Current Protection AEH series DC/DC converters feature foldback current limiting as part of their Overcurrent Protection (OCP) circuits. When output current exceeds 110 to 140% of rated current, such as during a short circuit condition, the output will shutdown immediately, and can tolerate short circuit conditions indefinitely. When the overcurrent condition is removed, the converter will automatically restart. TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 +Vout CNT Sense(+) Case Trim Radj-up RLOAD Sense(-) -Vin -Vout Radj-up = Vo(100+y) 1.26y - (100+2y) y Where y is the adjusting percentage of the voltage. 0 < y < 10 Radj-up is in k. Adjustment Resistor Value (k) Fig.10 Circuit Configuration and Equation to Trim Up Output Voltage 100 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 % Change In Output Voltage (y) Fig.11 Resistor Selection for Trimming Up 2.5V Outputs +Vin +Vout CNT Sense(+) Trim Case RLOAD Radj-down Sense(-) -Vin -Vout Radj-down = 100 y -2 where y is the adjusting percentage of the voltage. 0 < y < 10 Radj-down is in k. Fig.12 Circuit Configuration and Equation to Trim Down Output Voltage Adjustment Resistor Value (k) Output Trimming Trimming Users can increase or decrease the output voltage set point of a module by connecting an external resistor between the TRIM pin and either the SENSE (+ ) or SENSE ( - ) pins. The trim resistor should be positioned close to the module. If not using the trim feature, leave the TRIM pin open. Trimming up by more than 10% of the nominal output may damage the converter or trig the OVP protection. Trimming down more than 10% can cause the converter to regulate improperly. Trim down and trim up circuits and the corresponding configuration are shown in Figure 10 to Figure 13. Note that at elevated output voltages the maximum power rating of the module remains the same, and the output current capability will decrease correspondingly. +Vin 100 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 % Change In Output Voltage (y) Fig.13 Resistor Selection for Trimming Down Output Voltage Asia 852-2437-9662 852-2402-4426 -24www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Output Filters When the load is sensitive to ripple and noise, an output filter can be added to minimize the effects. A simple output filter to reduce output ripple and noise can be made by connecting a capacitor across the output as shown in Figure 14. The recommended value for the output capacitor C1 is 2,200F/10V. +Vout C1 Load -Vout load will decouple it. The capacitors should be connected as close to the load as possible. Ground Loops Ground loops occur when different circuits are given multiple paths to common or earth ground, as shown in Figure 16. Multiple ground points can slightly different potential and cause current flow through the circuit from one point to another. This can result in additional noise in all the circuits. To eliminate the problem, circuits should be designed with a single ground connection as shown in Figure 17. Fig.14 Output Ripple Filter RLine Extra care should be taken when long leads or traces are used to provide power to the load. Long lead lengths increase the chance for noise to appear on the lines. Under these conditions C2 can be added across the load as shown in Figure 15. The recommended component for C2 is 2200F/10V capacitor and connecting a 0.1F ceramic capacitor C1 in parallel generally. RLine +Vout Load Load RLine -Vout RLine RLine RLine Ground Loop Fig.16 Ground Loops RLine RLine +Vout Load +Vout C1 C2 -Vout Load RLine RLine -Vout Fig.15 Output Ripple Filter For a Distant Load Decoupling Noise on the power distribution system is not always created by the converter. High speed analog or digital loads with dynamic power demands can cause noise to cross the power inductor back onto the input lines. Noise can be reduced by decoupling the load. In most cases, connecting a 10 F tantalum capacitor in parallel with a 0.1F ceramic capacitor across the TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Load RLine Europe 44-(0)1384-842-211 44-(0)1384-843-355 Fig.17 Single Point Ground Output Over-Voltage Over-Voltage Protection The over-voltage protection has a separate feedback loop which activates when the output voltage is between 120% and 140% of the nominal output voltage. When an over-voltage condition occurs, a " turn off " signal was sent to the input of the module, and shut off the output. The module will restart after power on again. Asia 852-2437-9662 852-2402-4426 -25www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Parallel Power Distribution Figure 18 shows a typical parallel power distribution design. Such designs, sometimes called daisy chains, can be used for very low output currents, but are not normally recommended. The voltage across loads far from the source can vary greatly depending on the IR drops along the leads and changes in the loads closer to the source. Dynamic load conditions increase the potential problems. I1 + I2 + I3 I2 + I3 RL3 +Vout Load 1 Load 2 Load 3 -Vout RG2 RG1 RG3 RL = Lead Resistance RG = Ground Lead Resistance Fig.18. Parallel Power Distribution Radial Power Distribution Radial power distribution is the preferred method of providing power to the load. Figure 19 shows how individual loads are connected directly to the power source. This arrangement requires additional power leads, but it avoids the voltage variation problems associated with the parallel power distribution technique. +Vout RL3 RL1 RL2 Load 1 RG1 +Vout Load 2 Load 3 RG2 RG3 -Vout RL = Lead Resistance RG = Ground Lead Resistance Load 2 Load 3 Load 4 RG2 RG3 -Vout RG4 RL = Lead Resistance RG = Ground Lead Resistance Fig.20 Mixed Power Distribution Redundant Operation A common requirement in high reliability systems is to provide redundant power supplies. The easiest way to do this is to place two converters in parallel, providing fault tolerance but not load sharing. Oring diodes should be used to ensure that failure of one converter will not cause failure of the second. Figure 21 shows such an arrangement. Upon application of power, one of the converters will provide a slightly higher output voltage and will support the full load demand. The second converter will see a zero load condition and will "idle". If the first converter should fail, the second converter will support the full load. When designing redundant converter circuits, Shottky diodes should be used to minimize the forward voltage drop. The voltage drop across the Shottky diodes must also be considered when determining load voltage requirements. +Vout -Vout Mixed Distribution In the real world a combination of parallel and radial power distribution is often used. Dynamic and high current loads are connected using a radial design, while static and low current loads can be connected in parallel. This combined approach minimizes the drawbacks of a parallel USA 1-760-930-4600 1-760-930-0698 RL4 RL2 Load 1 RG1 Fig.19 Radial Power Distribution TEL: FAX: RL3 RL1 I3 RL2 RL1 design when a purely radial design is not feasible. Europe 44-(0)1384-842-211 44-(0)1384-843-355 Load +Vout -Vout Fig.21 Redundant Operation Asia 852-2437-9662 852-2402-4426 -26www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Thermal Management Technologies AEH Series 50 W to 150 W modules feature high efficiency and the 2.5 V output units have typical efficiency of 86% at full load. With less heat dissipation and temperature-resistant components such as ceramic capacitors, these modules exhibit good behavior during prolonged exposure to high temperatures. Maintaining the operating case temperature (Tc) within the specified range help keep internal-component temperatures within their specifications which in turn help keep MTBF from falling below the specified rating. Proper cooling of the power modules is also necessary for reliable and consistent operation. Basic Thermal Management Measuring the case temperature of the module (Tc) as the method shown in Figure 22 can verify the proper cooling. Figure 22 shows the metal surface of the module and the pin locations. The module should work under 90C for the reliability of operation and TC must not exceed 100 C while operating in the final system configuration. The measurement can be made with a surface probe after the module has reached thermal equilibrium. If a heat sink is mounted to the case, make the measurement as close as possible to the indicated position. It makes the assumption that the final system configuration exists and can be used for a test environment. The following text and graphs show guidelines to predict the thermal performance of the module for typical configurations that include heat sinks in natural or forced airflow environments. Note that Tc of module must always be checked in the final system configuration to verify proper TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 operational due to the variation in test conditions. 29.0 (1.14) 30.5 (1.2) MEASURE CASE TEMPERATURE HERE +Vin +Vout CNT +Sense Case - Sense Trim -Vin -Vout Base-plate side View Dimensions: millimeters (inches) Fig.22 Case Temperature Measurement Thermal management acts to transfer the heat dissipated by the module to the surrounding environment. The amount of power dissipated by the module as heat (PD) is got by the equation below: PD = PI PO where : PI is input power; PO is output power; PD is dissipated power. Also, module efficiency () is defined as the following equation: = PO / PI If eliminating the input power term, from two above equations can yield the equation below: PD = PO (1- )/ The module power dissipation then can be calculated through the equation. Because each power module output voltage has a different power dissipation curve, a plot of power dissipation versus output current over three different line voltages is given in each module-specific data sheet. The typical power dissipation curve of AEH series 2.5V output are shown as figure 23 to figure 26. Asia 852-2437-9662 852-2402-4426 -27www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Module Derating Power Dissipation (W) 5 4.5 4 3.5 3 Vin=36V 2.5 Vin=48V Vin=75V 2 0 1 2 3 4 5 6 7 8 9 10 Output Current (A) Fig.23 AEH10G48 Power Dissipation Curves Power Dissipation (W) 9 Experiment Setup From the experimental set up shown in figure 27, the derating curves as figure 28 can be drawn. Note that the PWB ( printed-wiring board ) and the module must be mounted vertically. The passage has a rectangular crosssection. The clearance between the facing PWB and the top of the module is kept 13 mm (0.5 in.) constantly. 8 7 6 5 FACING PWB PWB 4 Vin=36V 3 Vin=48V MODULE Vin=75V 2 0 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15 Output Current (A) Fig.24 AEH15G48 Power Dissipation Curves Power Dissipation (W) 9 AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE 8 7 76 (3.00) AIRFLOW 6 5 19 (0.75) Dimensions: millimeters (inches). 4 Vin=36V 3 Fig.27 Experiment Set Up Vin=48V Vin=75V 2 0 2 4 6 8 10 12 14 16 18 20 21 Output Current (A) Power Dissipation , PD (W) 16.5 Power Dissipation (W) 14.5 12.5 10.5 8.5 6.5 Vin=36V 4.5 Vin=48V 15 12 9 0.5 m/s (100 ft./min.) 6 0.1 m/s (20 ft./min.) Natural Convection 3 0 0 0 3 6 9 12 15 18 21 24 27 20 30 40 50 60 70 80 90 100 30 Output Current (A) Fig.26 AEH30G48 Power Dissipation Curves USA 1-760-930-4600 1-760-930-0698 10 Local Ambient Temperature, T A (C) Vin=75V 2.5 TEL: FAX: 4.0 m/s (800 ft./min.) 3.0 m/s (600 ft./min.) 2.0 m/s (400 ft./min.) 1.5 m/s (300 ft./min.) 1.0 m/s (200 ft./min.) 18 Fig.25 AEH20G48 Power Dissipation Curves Europe 44-(0)1384-842-211 44-(0)1384-843-355 Fig.28 Forced Convection Power Derating without Heat Sink Asia 852-2437-9662 852-2402-4426 -28www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Convection Without Without Heat Sinks Heat transfer can be enhanced by increasing the airflow over the module. Figure 28 shows the maximum power that can be dissipated by the module. In the test, natural convection airflow was measured at 0.05 m/s to 0.1 m/s (10 ft./min. to 20 ft./min.). The 0.5 m/s to 4.0 m/s (100 ft./min. to 800 ft./min.) curves are tested with externally adjustable fans. The appropriate airflow for a given operating condition can be determined through figure 28. Example 1. How to calculate the minimum airflow required to maintain a desired Tc? If a AEH30G48 module operates with a 48V line voltage, a 30 A output current, and a 40 C maximum ambient temperature, What is the minimum airflow necessary for the operating? Determine PD ( referenced Fig.26 ) with con- PO = (VO) x (IO) = 2.5 x 30 = 75 W Although the two examples above use 100 C as the maximum case temperature, for extremely high reliability applications, one may design to a lower case temperature as shown in Example 4. Heat Sink Configuration Several standard heat sinks are available for the AEH 50 W to 150 W modules as shown in Figure 29 to Figure 31. The heat sinks mount to the top surface of the module with screws torqued to 0.56 N-m (5 in.- 57.0 (2.24) TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 11.8 (0.465) Dimensions: millimeters (inches). 89.1(3.51) Fig.29 Non Standard Heatsink 1/4 IN. (WDL02540) dition: Vin = 48 V lO = 30 A Get: PD = 13.5 W And with TA = 40 C Determine airflow ( Fig.28. ): v = 1.5 m/s (300 ft./min.) Example 2. How to calculate the maximum output power of a module in a certain convection and a max. TA? What is the maximum power output for a AEH30G48 operating at following conditions: Vin = 48 V V = 1.5 m/s (300 ft./min.) TA = 40 C Determine PD ( Fig.28 ) PD = 14.5W Determine IO ( Fig.26 ): IO = 30 A Calculate PO: 4.9(0.193) 1/2 IN. (WDL05040) 1 IN. (WDL10040) 61 (2.4) 1 1/2 IN. (WDL15040) 57.9 (2.28) Fig.30 Longitudinal Fins Heat Sink 1/4 IN. (WDT02540) 1/2 IN. (WDT05040) 1 IN. (WDT10040) 57.9 (2.28) 1 1/2 IN. (WDT15040) 61 (2.4) Fig.31 Transverse Fins Heat Sink Asia 852-2437-9662 852-2402-4426 -29www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Heatsink Mounting Advice A crucial part of the thermal design strategy is the thermal interface between the baseplate of the module and the heatsink. Inadequate measures taken here will quickly negate any other attempts to control the baseplate temperature. For example, using a conventional dry insulator can result in a case-heatsink thermal impedance of >0.5 C/W, while use one of the recommended interface methods (silicon grease or thermal pads available from Astec) can result in a case-heatsink thermal impedance around 0.1C/W. Natural Convection with Heat Sink The power derating for a module with the heat sinks ( shown as figure 23 to figure 26) in natural convection is shown in figure 33. In this test, natural convection generates airflow about 0.05 m/s to 0.1 m/s ( 10ft./min to 20ft./min ). Figure 33 can be used for heat-sink selection in natural convection environment. 35 POWER DISSIPATION, PD (W) lb). A thermally conductive dry pad or thermal grease is placed between the case and the heat sink to minimize contact resistance (typically 0.1 C/W to 0.3 C/W) and temperature differential. Nomenclature for heat sink configurations is as follows: WDxyyy40 where: x = fin orientation: longitudinal (L) or trans verse (T) yyy = heat sink height (in 100ths of inch) For example, WDT5040 is a heat sink that is transverse mounted (see Figure 31) for a 61 mm x 57.9 mm (2.4 in.x 2.28 in.) module with a heat sink height of 0.5 in. 30 1 1/2 in. 1 in. 1/2 in. 1/4 in. NONE 25 20 15 10 5 0 0 10 20 30 40 50 60 70 80 90 100 LOCAL AMBIENT TEMPERATURE, TA (C) Fig.33 Heat Sink Power Derating Curves, Natural Convection Example 3. How to select a heat sink? What heat sink would be appropriate for a AEH30G48 in a natural convection environment at nominal line, 2/3 load, and maximum ambient temperature of 40C? Determine PD ( referenced Fig.26 ) with condition: Vin = 48 V IO = 2/3 (30) = 20 A TA = 40 C Get: PD = 7.5 W Determine Heat Sink (Fig.33.): no heat sink allows up to TA = 50 C 1/4 in. allows up to TA = 60 C Fig.32 Heat Sink Mounting TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -30www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W rise, PD is the module power dissipation. In this model, PD, TC, max, and RCA are equals to current flow, voltage drop, and electrical resistance, respectively, in Ohm's law, as shown in Figure 34. Also, TC, max is defined as the difference between the module case temperature (TC) and the inlet ambient temperature (TA). TC, max = TC TA Where TC is the module case temperature; TA is the inlet ambient temperature. BMPM PD = BMPM THERMAL RESISTANCE Fig.34 Basic Thermal Resistance Model For AEH Series 50W to 150W 2.5V output converters, the module's thermal resistance values versus air velocity have been determined experimentally and shown in figure 35. The highest values on each curve represents the point of natural convection. Figure 35 is used for determining thermal performance under various conditions of airflow and heat sink configurations. TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 8 Case-Ambient Thermal Resistance R CA (C/W) Basic Thermal Model There is another approach to analyze module thermal performance, to model the overall thermal resistance of the module. This presentation method is especially useful when considering heat sinks. The following equation can be used to calculate the total thermal resistance . RCA = TC, max / PD Where RCA is the module thermal resistance, TC, max is the maximum case temperature 7 1 in. HEAT SINK 1/2 in. HEAT SINK 1/4 in. HEAT SINK NO HEAT SINK 6 5 4 3 2 1 0 0 0.5 (100) 1.0 (200) 1.5 (300) 2.0 (400) 2.5 (500) 3.0 (600) Air Velocity m/s (ft./min.) Fig.35. Case-to-Ambient Thermal Resistance Curves; Either Orientation Example 4. How to determine the allowable minimum airflow to heat sink combinations necessary for a module under a desired Tc and a certain condition? Although the maximum case temperature for the AEH Series converters is 100 C, you can improve module reliability by limiting Tc,max to a lower value. How to decide? For example, what is the allowable minimum airflow for AEH 150W heat sink combinations at desired Tc of 80 C? The working condition is as following: Vin = 48 V, IO = 30 A, TA = 40 C Determine PD ( Fig.26 ) PD = 13.5 W Then solve RCA: RCA = TC, max / PD RCA = (TC - TA) / PD RCA = (80 - 40) / 13.5 = 3C/W determine air velocity from figure 35: If no heat sink: v = 2.6 m/s (520 ft./min.) If 1/4 in. heat sink: v = 1.8 m/s (360 ft./min.) If 1/2 in. heat sink: v = 1.1 m/s (220 ft./min.) If 1 in. heat sink: v = 0.4 m/s (80 ft./min.) Asia 852-2437-9662 852-2402-4426 -31www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Example 5. How to determine case temperature ( Tc ) for the various heat sink configurations at certain air velocity? What is the allowable Tc for AEH 150W heat sink configurations at desired air velocity of 2.0 m/s, and it is operating at a 48 V line voltage, a 30 A output current, a 40 C maximum ambient temperature? Determine PD ( Fig.26 ) with condition: Vin = 48 V IO = 30 A TA = 40 C v = 2.0 m/s (400 ft./min.) Get: PD = 13.5 W Determine TC: TC = (RCA x PD) + TA Determine the corresponding thermal resistances ( RCA ) from Figure 35: No heat sink: RCA = 3.8 C/W TC = (3.8 x 13.5) + 40 = 91 C 1/4 in. heat sink: RCA = 2.8 C/W TC = (2.8 x 13.5) + 40 = 78 C 1/2 in. heat sink: RCA = 2.0 C/W TC = (2.0 x 13.5) + 40 = 66 C 1 in. heat sink: RCA = 1.2 C/W TC = (1.2 x 13.5) + 40 = 56 C In this configuration, the heat sink would not need and the power module does not exceed the maximum case temperature of 100 C. nent life spans. Soldering AEH series converters are compatible with standard wave soldering techniques. When wave soldering, the converter pins should be preheated for 20-30 seconds at 110 C, and wave soldered at 260C for less than 10 seconds. When hand soldering, the iron temperature should be maintained at 425C and applied to the converter pins for less than 5 seconds. Longer exposure can cause internal damage to the converter. Cleaning can be performed with cleaning solvent IPA or with water. MTBF The MTBF, calculated in accordance with Bellcore TR-NWT-000332 is 2,080,000 hours. Obtaining this MTBF in practice is entirely possible. If the ambient air temperature is expected to exceed +25C, then we also advise a heatsink on the AEH, oriented for the best possible cooling in the air stream. ASTEC can supply replacements for converters from other manufacturers, or offer custom solutions. Please contact the factory for details. AEH Series Mechanical Considerations Installation Although AEH series converters can be mounted in any orientation, free air-flowing must be taken. Normally power components are always put at the end of the airflow path or have the separate airflow paths. This can keep other system equipment cooler and increase compo- TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Asia 852-2437-9662 852-2402-4426 -32www.astec.com AEH Half-Brick Power Converters 36VDC to 75VDC Input, 2.5V Output, 50-150W Recommend Hole Pattern Base-plate side view Dimensions are in millimeters and (inches). 57.9 (2.28) Max 4.8 (0.19) 48.3 (1.90) 48.26 (1.900) +Vin 35.56 (1.400) 50.8 (2.00) +Vout 35.56 (1.400) +Sense CNT 25.40 (1.000) Trim 25.40 (1.000) 10.16 (0.400) -Sense Case 61.0 (2.40) Max 17.78 10.16 (0.700) (0.400) -Vout -Vin 5.1 (0.20) 12.7 (0.50) Mounting Inserts Module Outline Mechanical Chart 5.1 (0.2) 61.0 (2.4) 7.62 (0.3) +Vin +Vout CNT +Sense 10.16 (0.4) 10.16 (0.4) 7.62 (0.3) 15.24 (0.6) Trim 7.62 (0.3) Case -Sense -Vin -Vout 10.16 (0.4) 10.16 (0.4) Mounting Inserts M3 thru hole x4 4.8 (0.19) 48.26 (1.9) mm (inches) 57.9 (2.28) Length optional 4.8 (0.189) default 12.7 (0.5) 7- 1.0 (0.04) all pins except +Vo and -Vo Pin Length Option 4.80mm ! 0.5mm 0.189in. ! 0.020in. 3.80mm ! 0.25mm 0.150in. ! 0.010in. 5.80mm ! 0.5mm 0.228in. ! 0.02in. 2.80mm ! 0.25mm 0.110in. ! 0.010in. TEL: FAX: USA 1-760-930-4600 1-760-930-0698 Europe 44-(0)1384-842-211 44-(0)1384-843-355 Device Code Suffix none (default) -6 -7 2- 2.0 (0.08) only +Vo and -Vo Tolerances: Inches .xx !0.020 .xxx !0.010 Pins >4mm <4mm -8 Asia 852-2437-9662 852-2402-4426 Millimeters .x !0.5 .xx !0.25 !0.02inch ( !0.5mm) !0.01inch ( !0.25mm) Base-plate side view -33www.astec.com PART NUMBER DESCRIPTION ss pp c - 0 iv L - iv = Input Voltage 05 = Range centered on 5V 12 = Range centered on 12V 24 = 18 to 36(2:1), 9 to 36V(4:1) 36 = 20 to 60V 46 = 18V to 75V (4:1) 48 = Typ 36 to 75V xxx f yy h n - p - mx-Options p = Pin Length Omit this digit for Standard 5mm 6 = 3.8mm, 7= 5.8mm 8 = 2.8mm Enable Logic Polarity Omit for Positive Enable Logic N = Negative Enable Except: AK60C-20H, BK60C-30H Omit for Negative Logice P = Positive Logic c = Pinout compatability A= Astec Footprint or "non Lucent" footprint C= Ind Std, Exact Lucent drop in pp = Package Type 40 = 1" x 2" SMD 42 = 1.5" x 2" SMD 45 = 1.45" X 2.3" (1/4 Brk) 60 = 2.4" X 2.3" (1/2 Brk) 80 = Full size 4.6" x 2.4" 72= 2.35" X 3.3 (3/4 Brk) H = High Efficiency (Synch rect.) Omit H if Conventional Diode (low Eff) yy = Output Current ie. 08 = 8 Amps f = # of Outputs F = Single Output D = Dual Output xxx = Output Voltage Format is XX.X (ie 1.8V = 018) ss = Series AA = 1/2brick Dual (Old designator) mx = Options M1,M2 = .25" Height Heatsink M3,M4 = .5" height Heatsink M5.M6 = 1.0" Height Heatsink AK = Ind Std sizes (1/4, 1/2, full) <150W AM/BM = Full size, astec pin out AL = Half size, astec pin-out BK = Ind Std size =>150W or feature rich AV = Avansys Product Note: For some products, they may not conform with the PART NUMBER DESCRIPTION above absolutely. REVISION Q ATTACHMENT I Page 1 of 2 NEW PART NUMBER DESCRIPTION A c s ii V1 V2 V3 Output Voltage A = 5.0V F = 3.3V G = 2.5V D = 2.0V / 2.1V Y = 1.8V M = 1.5V K = 1.2V J = 0.9V Vin - e t p Mx E = 7.5V B = 12V, C = 15V L = 8V, H = 24V, R = 28V Omit V2 and V3 if Single Output Omit V3 if Dual Output ie for Dual Output 5 and 3.3V V1 =A, V2 = F, V3 =Omit V1 =A, V2 = F, V3 =Omit ii = Output Current Max ie 60 = 60 Amps Vin = Input Voltage range 300 = 250V to 450V 48 = 36V to 75V 24 = 18V to 36V 03 = 1.8V to 5.0V 08 = 5.0V to 13.0V PFC: Power Factor Corrected S = Size F = Full Brick H = Half Brick Q = Quarter Brick S = 1 X 2 18 Pin SMT E = 1 X 2 Thru Hole C = (.53X1.3X.33) SMT (Austin Lite drop in) V = Conventional Package (2X2.56") or ( A = SIP W = Convent pkg (Wide 2.5X3) R = 1 X 1 Thru Hole A = SIP T = 1.6 X 2 E = Enable Logic for > 15W Omit this digit for Positive enable N = Negative Logic E = Enable Logic for < 15W Omit this digit for no enable option 1 = Negative Logic 4 = Positive Logic c = Construction E = Enhanced Thermals (Baseplate or adapter plate) I = Integrated (Full Featured) Hong Kong models L = Low Profile (Open Frame, No case - Isolated) P = Open Frame (SIP or SMT) non-isolated Trim for 1W to 15W 9 = Trim Added P = Pin Length Omit this digit for Standard 5mm 6 = 3.8mm 8 = 2.8mm 7 = 5.8 mm Mx - Factory Options customer Specific Note: For some products, they may not conform with the NEW PART NUMBER DESCRIPTION above absolutely. REVISION Q ATTACHMENT I Page 2 of 2