4B06B-512-RC - Surge Line Protection Module
Matched Pair of Resistors
Electrical Characteristics
Resistance Values (R1 = R2) .............................................5.6 - 100 Ω
Resistance Tolerance..................................................................±5 %
TCR ..................................................................................100 ppm/°C
Ratio Tolerance ...........................................................................±2 %
Temperature Range...................................................-40 ºC to +85 ºC
Physical Characteristics
Body Style ................................................................Open Frame SIP
Substrate Material ........................................................96 % Alumina
Lead Frame Material .......................................Copper, solder coated
Flammability .....................................................Conforms to UL94V-0
Wave Soldering .................................................260 °C for 3 seconds
Functional Characteristics (per Bellcore GR-1089)
First Level Lightning Surge -
Resistors will remain within tolerance after testing.
1000 Volts Peak, 100 Amp Peak Current,
Max. Rise/Min. Decay Time 10x1000 µs,
60 Seconds Between Pulses:
Number of Pulses ..............................25 each resistor each polarity
..........................................................25 simultaneous each polarity
2500 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10 µs,
60 Seconds Between Pulses:
Number of Pulses .............................10 simultaneous each polarity
First Level AC Power Fault -
Resistors will remain within tolerance after testing.
50 Vrms, 0.33 Amp Short Circuit Current:
Duration...........................................................................15 minutes
100 Vrms, 0.17 Amp Short Circuit Current:
Duration...........................................................................15 minutes
600 Vrms, 1.00 Amp Short Circuit Current:
Duration ........................................................60 One-second pulses
Second Level Lightning Surge -
Resistor package must fail safely causing no fire, electrical, or
framentation hazard.
5000 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10 µs:
Number of Pulses ...............................1 simultaneous each polarity
Second Level AC Power Fault -
Resistor package must fail safely causing no fire, electrical, or
framentation hazard.
Features
■RoHS compliant* versions available
■Overcurrent/lightning protection to BELLCORE GR-1089
■Typical application is secondary protection on telecom line cards
■UL497A recognition
■Thermal fuse links