MUR5005
THRU
MUR5060
50 Amp Supre Fast
Recovery Rectifier
50 to 600 Volts
Features
• Operating Temperature: -55°C to +175°C
• Storage Temperature: -55°C to +175°C
MCC
Part Number
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
MUR5005 50V 35V 50V
MUR5010 100V 70V 100V
MUR5020 200V 140V 200V
MUR5040 400V 280V 400V
MUR5060 600V 420V 600V
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
A ¼-28 Threads Standard Polarity
B .669 .687 17.19 17.44
C ----- .794 ----- 20.16
D ----- 1.020 ----- 25.91
E .422 .453 10.72 11.50
F .115 .200 2.93 5.08
G ----- .460 ----- 11.68
H .220 .249 5.58 6.32
J ----- .375 ----- 9.52
K .156 ----- 3.96 -----
M ----- .667 ----- 16.94 ∅
N ----- .080 ----- 2.03
P .140 .175 3.56 4.45 ∅
www.mccsemi .com
M
N
B
C
J
P
F
G
D
E
H
A
K
DO-5
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 50 A TC = 135°C
Peak Forward Surge
Current IFSM 600A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 50µA TJ = 25°C
Maximum Reverse
Recovery Time
5005-5020
5040 Trr 60ns
75ns IF=0.5A, IR=1.0A,
Irr=0.25A
6mA TJ = 125°C
5060 90ns
Typical Junction
Capacitance
5005-5020
5040
300pF
CJ 575pF Measured at
1.0MHz, VR=10V
5060
275pF
Maximum Reverse
Recovery Time
5005-5020
5040 Trr 60ns
75ns IF=0.5A, IR=1.0A,
Irr=0.25A
Maximum Ratings
• High Surge Capability
• Low Leakage
• Low Forward Voltage Drop
• High Current Capability
• Supre Fast switching for high efficiency
IFM = 50A;
TJ = 25°C
VF 1.15V
5005-5020
1.70V
5060 1.35V
5040
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
omponents
21201 Itasca Street Chatsworth
!"#
$% !"#
MCC