Discontinuedas asofofAugust August31, 31,2011 2011 Discontinued (10A, 15A, 20A type) 10A to 40A hockey puck type AQ-R (30A, 40A type) AQ-R RELAYS AQ-R FEATURES APPLICATIONS 1. Two types of terminal shape: Plugin terminal and Screw terminal (30 A, 40 A is screw terminal types only) 2. Flat type of SSR possible by aluminium printed circuit board 3. High dielectric strength of 1,500 V between input and output. 4,000 V available for 10A, 15A, 20A devices. 4. Heat sink and DIN mounting rail and terminal cover are available as accessories 1. Molding machine (heater control) 2. Temperature controlled bath (heater control) 3. Printing machine (heater control) 4. Machine tool (motor control) Product is discontinued. TYPES 1. Plug-in terminal type Type Load voltage 75 to 125V AC Zero-cross 10 A 75 to 250V AC 75 to 125 V AC Zero-cross 15 A 75 to 250 V AC 75 to 125 V AC Zero-cross 20 A 75 to 250 V AC Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC Standard (1,500V AC) Part No. AQR10A1-Z4/6VDC AQR10A1-Z10/18VDC AQR10A1-Z18/28VDC AQR10A2-Z4/6VDC AQR10A2-Z10/18VDC AQR10A2-Z18/28VDC AQR15A1-Z4/6VDC AQR15A1-Z10/18VDC AQR15A1-Z18/28VDC AQR15A2-Z4/6VDC AQR15A2-Z10/18VDC AQR15A2-Z18/28VDC AQR20A1-Z4/6VDC AQR20A1-Z10/18VDC AQR20A1-Z18/28VDC AQR20A2-Z4/6VDC AQR20A2-Z10/18VDC AQR20A2-Z18/28VDC Reinforced (4,000V AC) Part No. -- -- -- AQR10A2-ZV4/6VDC AQR10A2-ZV10/18VDC AQR10A2-ZV18/28VDC -- -- -- AQR15A2-ZV4/6VDC AQR15A2-ZV10/18VDC AQR15A2-ZV18/28VDC -- -- -- AQR20A2-ZV4/6VDC AQR20A2-ZV10/18VDC AQR20A2-ZV18/28VDC Standard (1,500V AC) Part No. AQR10A1-S-Z4/6VDC AQR10A1-S-Z10/18VDC AQR10A1-S-Z18/28VDC AQR10A2-S-Z4/6VDC AQR10A2-S-Z10/18VDC AQR10A2-S-Z18/28VDC AQR15A1-S-Z4/6VDC AQR15A1-S-Z10/18VDC AQR15A1-S-Z18/28VDC AQR15A2-S-Z4/6VDC AQR15A2-S-Z10/18VDC AQR15A2-S-Z18/28VDC AQR20A1-S-Z4/6VDC AQR20A1-S-Z10/18VDC AQR20A1-S-Z18/28VDC AQR20A2-S-Z4/6VDC AQR20A2-S-Z10/18VDC AQR20A2-S-Z18/28VDC AQR30A2-S-Z4/6VDC AQR30A2-S-Z10/18VDC AQR30A2-S-Z18/28VDC AQR40A2-S-Z4/6VDC AQR40A2-S-Z10/18VDC AQR40A2-S-Z18/28VDC Reinforced (4,000V AC) Part No. -- -- -- AQR10A2-S-ZV4/6VDC AQR10A2-S-ZV10/18VDC AQR10A2-S-ZV18/28VDC -- -- -- AQR15A2-S-ZV4/6VDC AQR15A2-S-ZV10/18VDC AQR15A2-S-ZV18/28VDC -- -- -- AQR20A2-S-ZV4/6VDC AQR20A2-S-ZV10/18VDC AQR20A2-S-ZV18/28VDC -- -- -- -- -- -- 2. Screw-terminal type Type Load voltage 75 to 125 V AC Zero-cross 10 A 75 to 250 V AC 75 to 125 V AC Zero-cross 15 A 75 to 250 V AC 75 to 125 V AC Zero-cross 20 A 75 to 250 V AC Zero-cross 30 A 75 to 250 V AC Zero-cross 40 A 75 to 250 V AC ds_61608_en_aqr: 010611D Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 4 to 6V DC 10 to 18V DC 18 to 28V DC 1 AQ-R Discontinued as of August 31, 2011 ORDERING INFORMATION Ex. AQR 10A 1 S Z 4/6VDC Load current Load voltage Terminal shape Type Input voltage 10 A, 15 A, 20 A, 30 A, 40 A 1: 75 to 125 V AC 2: 75 to 250 V AC Nil: Plug-in terminal S: Screw terminal Z: Zero-cross type (1,500 V) ZV: Zero-cross type (4,000 V) 4/6, 10/18, 18/28 V DC Note: Standard packing: Carton 10 pcs., Case: 100 pcs. SPECIFICATIONS 1. Ratings (at 20C 68F, Input ripple: 1% or less) 1) 10 A type Part No. AQR10A1-Z4/ 6VDC AQR10A1-Z10/ 18VDC AQR10A1-Z18/ 28VDC AQR10A2-Z4/ 6VDC AQR10A2-ZV4/ 6VDC AQR10A2-Z10/ 18VDC AQR10A2-ZV10/ 18VDC AQR10A2-Z18/ 28VDC AQR10A2-ZV18/ 28VDC AQR10A2-S-Z10/ 18VDC AQR10A2-SZV10/18VDC 10 to 18V DC Approx. 0.86 k AQR10A2-S-Z18/ 28VDC AQR10A2-SZV18/28VDC 18 to 28V DC Approx. 1.36 k AQR10A1-S-Z4/ 6VDC AQR10A1-S-Z10/ 18VDC AQR10A1-S-Z18/ 28VDC AQR10A2-S-Z4/ 6VDC AQR10A2-S-ZV4/ 6VDC 4 to 6V DC Approx. 0.26 k 10 to 18V DC Approx. 0.86 k 18 to 28V DC Approx. 1.36 k 4 to 6V DC Approx. 0.26 k Items Input side Input voltage Input impedance Drop-out voltage, min. 1V Max. load current Load side See "REFERENCE DATA 1" 10 A Load voltage Frequency Repetitive peak voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Remarks 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 100 A 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at max. carrying current 1.6 V Min. load current OFF-state dV/dt at 60 Hz 100 mA 100 V/s 2) 15 A type Part No. AQR15A1-Z4/ 6VDC AQR15A1-Z10/ 18VDC AQR15A1-Z18/ 28VDC AQR15A1-S-Z4/ 6VDC AQR15A1-S-Z10/ 18VDC AQR15A1-S-Z18/ 28VDC 4 to 6V DC Approx. 0.26 k 10 to 18V DC Approx. 0.86 k 18 to 28V DC Approx. 1.36 k Items Input side Input voltage Input impedance Drop-out voltage, min. Load side Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current OFF-state dV/dt 2 AQR15A2-Z10/ 18VDC AQR15A2-ZV10/ 18VDC AQR15A2-S-Z10/ 18VDC AQR15A2-SZV10/18VDC 4 to 6V DC Approx. 0.26 k 10 to 18V DC Approx. 0.86 k AQR15A2-Z18/ 28VDC AQR15A2-ZV18/ 28VDC AQR15A2-S-Z18/ 28VDC AQR15A2-SZV18/28VDC 18 to 28V DC Approx. 1.36 k Remarks 1V Max. load current Load voltage Frequency Repetitive peak voltage Non-repetitive surge current AQR15A2-Z4/ 6VDC AQR15A2-ZV4/ 6VDC AQR15A2-S-Z4/ 6VDC AQR15A2-S-ZV4/ 6VDC See "REFERENCE DATA 1" 15 A 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 150 A 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) 1.6 V at 60 Hz at max. carrying current 100 mA 100 V/s ds_61608_en_aqr: 010611D AQ-R Discontinued as of August 31, 2011 3) 20 A type Part No. AQR20A1-Z4/ 6VDC AQR20A1-Z10/ 18VDC AQR20A1-Z18/ 28VDC AQR20A1-S-Z4/ 6VDC AQR20A1-S-Z10/ 18VDC AQR20A1-S-Z18/ 28VDC 4 to 6V DC Approx. 0.26 k 10 to 18V DC Approx. 0.86 k 18 to 28V DC Approx. 1.36 k Items Input side Input voltage Input impedance Drop-out voltage, min. AQR20A2-Z10/ 18VDC AQR20A2-ZV10/ 18VDC AQR20A2-S-Z10/ 18VDC AQR20A2-SZV10/18VDC 10 to 18V DC Approx. 0.86 k AQR20A2-Z18/ 28VDC AQR20A2-ZV18/ 28VDC AQR20A2-S-Z18/ 28VDC AQR20A2-SZV18/28VDC 18 to 28V DC Approx. 1.36 k Remarks 1V Max. load current Load side AQR20A2-Z4/ 6VDC AQR20A2-ZV4/ 6VDC AQR20A2-S-Z4/ 6VDC AQR20A2-S-ZV4/ 6VDC 4 to 6V DC Approx. 0.26 k See "REFERENCE DATA 1" 20 A Load voltage Frequency Repetitive peak voltage Non-repetitive surge current 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V In one cycle at 60 Hz 200 A Max. "OFF-state" leakage current Max. "ON-state" voltage drop 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz at max. carrying current 1.6 V Min. load current OFF-state dV/dt 100 mA 100 V/s 4) 30 A type and 40 A type Part No. Items Input side Input voltage Input impedance Drop-out voltage, min. AQR30A2-S-Z4/ 6VDC 4 to 6V DC Approx. 0.26 k Max. load current Load side Load voltage Frequency Non-repetitive surge current AQR30A2-S-Z10/ 18VDC 10 to 18V DC Approx. 0.86 k AQR30A2-S-Z18/ 28VDC 18 to 28V DC Approx. 1.36 k AQR40A2-S-Z4/ 6VDC 4 to 6V DC Approx. 0.26 k AQR40A2-S-Z10/ 18VDC 10 to 18V DC Approx. 0.86 k AQR40A2-S-Z18/ 28VDC 18 to 28V DC Approx. 1.36 k Remarks 1V 30 A 40 A See "REFERENCE DATA 1" 400 A In one cycle at 60 Hz 75 to 250 V AC 45 to 65 Hz 300 A Max. "OFF-state" leakage current Max. "ON-state" voltage drop 5 mA (when 200 V AC applied) 1.6 V Min. load current at 60 Hz at max. carrying current 120 mA 2. Characteristics (at 20C 68F, Input ripple: 1% or less) Type Item Operate time, max. Release time, max. Insulation resistance, min., Initial Breakdown voltage Vibration resistance Functional Destructive Functional Destructive Ambient temperature Storage temperature Operational method Shock resistance Zero-cross type Standard type Reinforced type (1/2 cycle of voltage sine wave) + 1 ms (1/2 cycle of voltage sine wave) + 1 ms 100 M between input, output and case 1,500 V AC between input, output and case 4,000 V AC between input, output and case 10 to 55 Hz at double amplitude of 2 mm* 10 to 55 Hz at double amplitude of 2 mm* Min. 980 m/s2 {100 G} Min. 980 m/s2 {100 G} -20C to +80C -4F to +176F -25C to +85C -13F to +185F Zero-cross (Turn-ON and Turn-OFF) Remarks by 500V DC megger For 1 min. 1 hour for X, Y, Z axes 10 minutes for X, Y, Z axes 5 time each for X, Y, Z axes 4 time each for X, Y, Z axes Note: * 30 A and 40 A type is 10 to 55 Hz at double amplitude of 1.5 mm. ds_61608_en_aqr: 010611D 3 AQ-R Discontinued as of August 31, 2011 DIMENSIONS(mm inch) CAD Data Data from our Web site. Download CAD 1. Plug-in terminal Schematic CAD Data Input power source _ + 44.8 26 1.764 1.024 9 .354 Mounting hole Conform to AMP plug-in terminal #110 series receptacle Load power source Mounting dimensions (Bottom view) 2-4.4 dia. 2-.173 dia. 47.6 1.874 59 2.323 Load 47.6 - 0.1 1.874 - .004 2-4.3 dia. or M4 2-.169 dia. Conform to AMP plug-in terminal #250 series receptacle Max. 15 Max. .591 Max. 7.5 Max. .295 Max. 12.5 Max. .492 2. Screw terminal Schematic CAD Data Input power source 4-M4 screw terminal _ + Load Load power source 44.8 26 1.764 1.024 9 .354 Mounting hole Mounting dimensions (Bottom view) 2-4.4 dia. 2-.173 dia. 45.0 1.772 47.6 1.874 59 2.323 47.6 - 0.1 1.874 - .004 2-4.3 dia. or M4 2-.169 dia. Max. 17 Max. .669 Max. 7.5 Max. .295 max. 12.5 Max. .492 ACCESSORIES Heat sink (For 10 A, 15A and 20 A) Mounting dimensions (Bottom view) CAD Data 4.4 .173 50 1.969 4.4 .173 R2.2 .087 2 .079 4-M4 or 4.4 dia 1.5 .059 2-M4 AQP-HS-20A 9.5 33.3 100 +-1.5 1.311 3.937 +.929 -.059 80 3.150 11.1 .437 54 2.126 90 3.543 2 .079 47.6 1.874 100 3.937 24.5 .965 28.5 9 1.122 .354 45 1.772 90 - 0.1 3.543 - .004 1.5 .059 50 - 0.2 1.969 - .008 General tolerance: 0.5 .020 4 ds_61608_en_aqr: 010611D AQ-R Discontinued as of August 31, 2011 Heat sink (For 30 A, 40 A) mm inch CAD Data Mounting dimensions (Bottom view) 50 1.969 4.4 .173 4.4 .173 4-M4 or 4.4 dia 11.1 .437 R 2.2 .087 3-M4 90 3.543 2 .079 80 3.150 33.3 100+0.5 -1.5 1.311 3.937+.020 90 - 0.1 -.0593.543 - .004 54 2.126 47.6 1.874 1.5 .059 AQP-HS-30/40A 2 .079 56 2.205 150 5.906 1.5 .059 50 - 0.2 1.969 - .008 24.5 .965 28.5 1.122 45 1.772 9 .354 General tolerance: 0.5 .020 With terminal cover CAD Data 59 2.323 1.5 .059 11.5 .453 47 1.850 5.5 .217 1.5 .059 AQP-PC 24.5 .965 General tolerance: 0.5 .020 DIN rail mounting plate Mounting rail CAD Data CAD Data 13.6 .535 M4 M4 56 2.205 47.6 1.874 M4 18.1 .713 44 1.732 AT8-DLA1 AQP-DP 1,000 39.37 70 2.765 86 3.386 5.5 .217 5 .197 15 10 15 .591 .394 .591 2.75R 15 10 15 .108R .591 .394 .591 40-5.5 x 15 slot 40-.217 x .591 slot 35 1.378 24 5 .945 1.5 .059 .197 General tolerance: 0.5 .020 ds_61608_en_aqr: 010611D 27 1.063 7.5 .295 5 AQ-R Discontinued as of August 31, 2011 Fastening plate mm inch CAD Data 50 M4 1.969 12 .472 10 .394 ATA4806 UP ATA4806 10 .394 REFERENCE DATA 1. Load current vs. ambient temperature Use load current within range specified in the figure below. Tested condition: With external heat sink 1) (1) 10 A, 15A, 20 A type * A heat sink; optional heat sink (AQP801) or a 1501503.2 mm aluminum sheet (painted black) (2) 30 A, 40 A type Shown with standard heat sink (AQP804) 2) If attached to a heat sink, use a heatconductive compound or similar coating to improve cooling. Without external heat sink If the mounting surface is not metallic and a heat sink is not used, expose the bottom surface and plate surface to improve heat dissipation. The graphs show the characteristics when the relay is mounted as shown in the right figure. (2) 15 A type (3) 20 A type (1) 10 A type 3 mm or greater Washers are added to lift the relay. Load current, A Hole for radiation (40x35 mm) 10 With external heat sink 8 6 Without external heat sink 4 2 0 -30 0 20 40 60 80 Ambient temperature, C (4) 30 A type 50 16 15 12 Without external heat sink Load current, A Load current, A With external With external heat sink 16 12 Without external heat sink 8 7 6 4 8 2 0 -30 2 0 -30 40 Load current, A 20 20 20 40 60 80 Ambient temperature, C (5) 40 A type 20 Without external heat sink 10 4 0 With external heat sink 30 0 0 -30 20 40 60 80 Ambient temperature, C 2-1. Non-repetitive surge current vs. carrying time (10 A type) 0 20 40 60 80 Ambient temperature, C 2-2. Non-repetitive surge current vs. carrying time (15 A type) Load current, A 30 20 Without external heat sink 10 Non-repetitive surge current, A With external heat sink 40 Non-repetitive surge current, A 50 220 200 180 160 140 120 100 80 60 40 6 0 20 40 60 80 Ambient temperature, C 0 200 180 160 140 120 100 80 60 40 20 0 -30 220 20 1 2 3 4 5 7 10 20 30 40 50 70 100 No. of cycles at 60 Hz 0 1 2 3 4 5 7 10 20 30 40 50 70 100 No. of cycles at 60 Hz ds_61608_en_aqr: 010611D AQ-R Discontinued as of August 31, 2011 2-3. Non-repetitive surge current vs. carrying time (20 A type) 2-4. Non-repetitive surge current vs. carrying time (30 A, 40 A type) 3. Input current vs. input voltage (10 A, 15 A, 20 A, 30 A, 40 A common) 30 200 180 160 140 120 100 80 60 25 400 300 40A type 30A type 200 (4 to 6 V) 20 (10 to 18 V) 15 (18 to 28 V) 10 100 40 Input current, mA Non-repetitive surge current, A Non-repetitive surge current, A 500 220 5 20 0 1 2 3 4 5 7 10 20 30 40 50 70 100 No. of cycles at 60 Hz 0 1 2 3 4 5 7 10 20 304050 70 100 No. of cycles at 60 Hz 0 0 5 10 20 15 Input voltage, V 25 30 Cautions for Use ds_61608_en_aqr: 010611D 7