IN FI PD
2007-07-12
Please read Cautions and warnings and
Important notes at the end of this document. Page 1 of 6
EMC filters
1-line filter
Feedthrough Filter in Solderless Technology
Series/Type: B85321A2363G300 Feedthrough Filter
Date: July 2007
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to “white” (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol “Preview” and then “Close”. Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar) 1-line filter
Identification/Classification 2:
(header 2 + bottom left header bar) Feedthrough Filter
Ordering code:
(top right header bar) B85321A2363G300
Series/Type:
(top right header bar) Ø 20 , 30A
Preliminary data (optional):
(if necessary)
Department: IN FI PD
Date: 2007-07-12
EPCOS AG 2006. Reproduction, publication and dissemination of this document, enclosures hereto and the information
contained therein without EPCOS’ prior express consent is prohibited.
1-line filter B85321A2363G300
Feedthrough Filter Ø 20 , 30A
IN FI PD
2007-07-12
Please read Cautions and warnings and
Important notes at the end of this document. Page 2 of 6
Feedthrough Filter: Metallized (selfhealing) film capacitor. High insertion losses up to the GHZ
range.
Rated voltage 250 V AC (50/60Hz), 600 V DC
Rated current 30 A
Construction
1-line filters, Building-block system
Metal case with synthetic resin terminals (UL 94 V-0)
MKP/MKT technology (dry, self-healing), Dielectric: polypropylene/polyester metallised
For central screw fixing
Features
Excellent price/performance ratio
Ultra-compact design
High attenuation
Easy to install
High contact reliability through central screw fixing
RoHS conform
Applications
Shielded rooms
Power supplies
Telephone exchanges, base stations
Electrical machines and systems
Terminals
Threaded studs / axial leads
EPCOS internal code for production location
(not marked on component)
Production Szombathely, Hungary : V1
Production Hongqi, China : Z99
Marking
Marking on component:
Manufacturer’s logo, ordering code, rated voltage,
rated current, test voltage, climatic category, date code (MM.YY), rated capacitance
1-line filter B85321A2363G300
Feedthrough Filter Ø 20 , 30A
IN FI PD
2007-07-12
Please read Cautions and warnings and
Important notes at the end of this document. Page 3 of 6
Typical circuit diagram:
Technical data and measuring conditions
Rated capacitance 2 x 0,018 µF, ± 20% ,
Rated voltage V
R
250 V AC, 50/60 Hz, 600 V DC
Rated current I
R
30 A, Referred to 40 °C ambient temperature
Test voltage V
test
2700 V DC, 2s , (lines/case)
Climatic category (IEC 60068-1) 40/085/56 (-40 °C/+85 °C/ 56 days damp heat test)
Approx. weight 65g
Terminals M 5 / Ø 2,36
Fixing M 12x0,75
Approvals comply with EN 132400 / EN133200
Characteristics and ordering codes
V
R
AC I
R
U
R
U
R
U
test
Approx.
weight Ordering code Approvals
V A VAC VDC VDC/2s kg
ENEC
20.08.2002 B/T
70%
16.03.2004 B/T
10
URType
15.03.2004 B/T
70%
UR
C-URType
15.03.2004 B/T
70%
C-UR
250 30 250 600 2700 0.065 B85321A2363G300 X
X = approval granted
1-line filter B85321A2363G300
Feedthrough Filter Ø 20 , 30A
IN FI PD
2007-07-12
Please read Cautions and warnings and
Important notes at the end of this document. Page 4 of 6
Dimensional drawings
B85321A2363G300
MATERIAL:
Metal case, nickel plated. UL-listed material for resin and plastic insulting bush.
Terminals, nuts and washers are nickel- or tin plated.
Mounting instructions:
In case of using a screw fixing type the connecting line must be attached by fixing it between two
countered nuts in order to avoid exposing the component to torque loads (use two spanners)
Insertion loss (typical values at Z = 50 Ω)
f 10
KHz 100
KHz 1
MHz 10
MHz 100
MHz 1
GHz
dB 1 10 62 >100 >100
1-line filter B85321A2363G300
Feedthrough Filter Ø 20 , 30A
IN FI PD
2007-07-12
Please read Cautions and warnings and
Important notes at the end of this document. Page 5 of 6
Cautions and warnings
Please note the advices in our data book “EMC filters” (latest edition); attention should be paid to the
chapters “Important notes” and “General safety notes”.
It should be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge.
Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even
after the power has been switched off.
The protective earth connections should be the first to be made when the EMC filter is installed
and the last to be disconnected. Depending on the magnitude of the leakage currents, the
particular specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as with circuits able to cause resonances,
impermissible voltages at higher frequencies etc. can lead to destruction of the filter housing.
EMC filters must be protected in the application against impermissible exceeding of the rated
currents by overcurrent protective.
In case of leakage currents > 3.5 mA you shell mount the PE conductor stationary with the
required cross section before beginning of operation and save it against disconnecting. For
leakage currents I
L
< 10 mA the PE conductor must have a KU value of 4.5; for leakage currents I
L
> 10 mA the PE conductor must have a KU value of 6.
1
1
The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous
body currents and exessive heating.
KU = 6 with respect to interruptions is achieved for fixed-connection lines 10 mm
2
where the type of connection and line layout
corresponds to the requirements for PEN conductors as specified in relevant standards.
A value of KU = 4.5 with respect to interruptions is attained:
- With a permanently connected protective earth circuit 1.5 mm
2
- With a protective earth circuit 2.5 mm
2
connected via shroud connectors (IEC 60309-2).
1-line filter B85321A2363G300
Feedthrough Filter Ø 20 , 30A
IN FI PD
2007-07-12
Please read Cautions and warnings and
Important notes at the end of this document. Page 6 of 6
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components or
failure before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of a passive electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g. because
they are classed as “hazardous”). Useful information on this will be found in our Material Data
Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions,
please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
6.
Unless otherwise agreed in individual contracts, all orders are subject to the current version of the
“General Terms of Delivery for Products and Services in the Electrical Industry” published by the
German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI,
SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks
registered or pending in Europe and in other countries. Further information will be found on the
Internet at www.epcos.com/trademarks.