Click on Series name for product info on aimtec.com Series AM12T-Z 12 Watt | DC-DC Converter FEATURES: * * * * * Wide Input Range 2:1 1600 Vdc Isolation Efficiency up to 91% Soft Start Remote On/Off Function * * * * * No Minimum Load Required -40C to +85C Operating Temperature Range Short Circuit & Over Voltage Protection DIP 24 Package Low No Load Input Current Models Single output Model Input Voltage (V) AM12T-1202SZ AM12T-1203SZ AM12T-1205SZ AM12T-1212SZ AM12T-1215SZ AM12T-2402SZ AM12T-2403SZ AM12T-2405SZ AM12T-2412SZ AM12T-2415SZ AM12T-4802SZ AM12T-4803SZ AM12T-4805SZ AM12T-4812SZ AM12T-4815SZ 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 Output Voltage (V) Output Current max (mA) Isolation (VDC) Maximum Capacitive load (F) Efficiency (%) 3500 3500 2400 1000 800 3500 3500 2400 1000 800 3500 3500 2400 1000 800 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 2000 2000 2000 430 300 2000 2000 2000 430 300 2000 2000 2000 430 300 85 87 89 90 90 85 87 89 90 90 84 88 89 88 89 2.5 3.3 5 12 15 2.5 3.3 5 12 15 2.5 3.3 5 12 15 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Maximum Capacitive load (F) Efficiency (%) AM12T-1212DZ AM12T-1215DZ AM12T-2412DZ AM12T-2415DZ AM12T-4812DZ AM12T-4815DZ 9-18 9-18 18-36 18-36 36-75 36-75 12 15 12 15 12 15 500 400 500 400 500 400 1600 1600 1600 1600 1600 1600 200 120 200 120 200 120 90 91 90 91 88 89 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Input Specifications Parameters Voltage range Filter Turn on Transient process time Transient response deviation Start up time Absolute Maximum Rating www.aimtec.com F 051e R12.G Nominal 12 24 48 Typical Maximum 9-18 18-36 36-48 (Pi) Network 250 VDC 3 Nominal Vin and constant resistive load 12 Vin models 24 Vin models 48 Vin models Tel: +1 514 620 2722 1 of 3 20 -0.7-36 -0.7-50 -0.7-100 Units s % ms VDC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM12T-Z 12 Watt | DC-DC Converter Input Specifications (continued) Parameters Nominal Peak Input Voltage time Input reflected ripple current Quiescent Current Typical Maximum Units 1000 20 ms mA p-p mA 15 ON - High (3.0 ... 12Vdc) or open circuit; OFF - Low (0 ... 1.2Vdc) or Short circuit pin1 and pin 2/3 OFF idle current: 5.0 mA typ On/Off Control Isolation Specifications Parameters Tested I/O voltage Tested Case/Input and Output Resistance Capacitance Conditions Typical 3 sec Rated Units 1600 VDC VDC MOhm pF Maximum Units 1600 >1000 1200 Output Specifications Parameters Voltage accuracy Voltage balance Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Over voltage protection Over current protection Short Circuit protection Short circuit restart Ripple & Noise Conditions Dual output HL-LL 0% Load to Full Load 0% Load to Full Load Full Load Typical 1.2 5 0.5 0.5 1.0 Zener diode clamp 150 Continuous Auto recovery 85 % % % % % % m Vp-p General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Temperature coefficient Derating Cooling Humidity Case material Potting material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Full Load with Derating above 60C 330 Maximum -40 to +85 -40 to +125 100 Above 60C 0.02 2.5 % per 1C Free air convection Units KHz oC oC oC %/oC 95 % RH Nickel-coated Copper UL94V-0 rated 18.0 g Tolerance 0.5 mm or 0.02 inches 1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm >1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Safety Specifications Parameters Agency Approval Standards www.aimtec.com F 051e R12.G CE IEC 60950-1:2005 (2nd Edition); EN 60950-1: 2006 EN55032 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM12T-Z 12 Watt | DC-DC Converter Pin Out Specifications Derating Pin Single Dual 1 2 3 9 11 14 16 22 23 Remote On/Off -V Input -V Input No Pin N.C. +V Output -V Output +V Input +V Input Remote On/Off -V Input -V Input Common -V Output +V Output Common +V Input +V Input Dimensions 22.90 (0.90) 0.50 (0.02) 20.32 (0.80) 1 2 3 9 11 Bottom View 16 14 23 22 5.08 (0.20) 2.54 (0.10) Printed Face 15.24 (0.60) 31.75 (1.25) Built-in Stand-offs to ease PCB cleaning 3.05 (0.12) 10.16 (0.40) All dimensions are typical: millimeters (inches) Pin Diameter: 0.50 0.05 (0.02 0.002) Pin Pitch Tolerance: 0.35 (0.014) Case Tolerence: 0.5 (0.02) Test Circuits Conducted Emmisions : Surge: +Vout +Vout L 12uH +Vin +Vin DC/DC Converter C1 100uF, 100V Load DC/DC Converter C1 330uF, 100V -Vin Load -Vin -Vout -Vout NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only