RK
104
4.-(1) Mechanical life test (Single side stable)
Sample: RK1-12V; No. of samples: n = 12
4.-(2) Mechanical life test (Latching)
Sample: RK1-L2-12V
No. of samples: n = 12
4.-(3) Mechanical life test
Sample: RK1-12V
No. of samples: n = 20 (20
×
2 contacts)
0
2
4
6
8
10
12
100 500 1,000
Min.
Max.
Min.
Max.
No. of operations, ×104
Pick-up/drop-out voltage, V
Pick-up voltage
Drop-out voltage
0
2
4
6
8
10
12
100 500 1,000
Min.
Max.
No. of operations, ×104
Set/Reset voltage, V
0
50
100
150
200
250
300
50 100 500 1,000
Min.
Max.
No. of operations, ×104
Contact resistance, mΩ
5. Electrical life test (0.01 A 24 V DC)
Sample: RK1-12V; No. of samples: n = 6
6. Ambient temperature characteristics
Sample: RK1-12V; No. of samples: n = 6
7. Contact resistance distribution (initial)
Sample: RK1-12V
No. of samples: n = 50 (50
×
2 contacts)
0
2
4
6
8
10
12
10 20 30
Min.
Max.
Min.
Max.
No. of operations, ×104
Pick-up/drop-out voltage, V
Pick-up voltage
Drop-out voltage
–40
–40 –20
–4 020
68
40
20
–20
–40
Rate of change, %
Ambient temperature,
°C °F
40
104
60
140 80
176
Pick-up voltage
Drop-out voltage
0
10
20
30
40
50
10 20 30 40 50
Contact resistance, mΩ
Quantity
8.-(1) Influence of adjacent mounting
Sample: RK1-12V; No. of sample: n = 10
8.-(2) Influence of adjacent mounting
Sample: RK1-12V; No. of samples: n = 10
–10
0
10
–10
0
10
5
.197 10
.394
ON ON
OFF OFF
OFF condition
ON condition
Inter-relay distance, (mm, inch)
Rate of change, % Rate of change, %
Pick-up voltage
Drop-out voltage ON
ON
OFF
OFF
–10
0
10
–10
0
10
5
.197 10
.394
0
10
OFF condition
Inter-relay distance, (mm, inch)
Rate of change, % Rate of change, %
ON condition
Drop-out voltage
Pick-up voltage
NOTES
1. Soldering
Perform soldering under the conditions
below.
• Within 10 s at 260°C 500°F
• Within 3 s at 350°C 662°F
2. Latching relay
In order to assure proper operating re-
gardless of changes in the ambient usage
temperature and usage conditions, nomi-
nal operating voltage should be applied to
the coil for more than 30 ms to set/reset
the latching type relay.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog