Termination-Insensitive Mixer, 1 MHz - 3.5 GHz MD-/MDC-/MDS-169
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
V 3.00
2
Electrical Specifications1(MD-/MDC-169): TA = -55°C to +85°C
Parameter Test Conditions Frequency Units Min Typ Max
Frequency Range RF, LO Ports
IF Port 0.001 - 3.5
5 - 1500 GHz
MHz —
— —
— —
—
Conversion Loss 5 - 1000 MHz 2
5 - 3000 MHz 3
1 - 3500 MHz
dB
dB
dB
—
—
—
—
—
—
7
8
10
Isolation LO to RF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 —
— —
—
LO to IF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 —
— —
—
RF to IF 10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
30
20
18
—
—
—
—
—
—
RF Input 1 dB Compression
1 dB Desensitization —
— dBm
dBm —
— +7
+5 —
—
SSB Noise Figure Within 1 dB of Conversion Loss
Max — — — — —
Typical Two-Tone IM
Ratio with a –10 dBm input, each input,
25 MHz and 35 MHz IF 10 MHz
500 MHz
3000 MHz
dB
dB
dB
—
—
—
55
58
56
—
—
—
3rd Order
Intermodulation Ratio
Degradation
@ IF VSWR 3:1 — dB — 3 —
1. All specifications apply when operated at +10 available LO power with 50 Ohm source and load impedance.
2. For IF Frequencies of 5 - 300 MHz and RF of –10 dBm or less.
3. For MDC-169, add 1.0 dB to conversion loss.
Parameter Test Conditions Frequency Units Min Typ Max
Conversion Loss LO @ +10 dBm
IF @ 60 MHz 5 - 1000 MHz
1000 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
—
—
—
6.5
7.5
8.0
7.0
9.0
10.0
LO to RF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 35
25 —
—
LO to IF 5 - 1000 MHz
1 - 3500 MHz dB
dB 30
20 35
25 —
—
RF to IF 10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
30
20
18
35
25
23
—
—
—
Isolation
Electrical Specifications (MDS-169): TA = -55°C to +85°C,
Frequency: RF, LO Ports = 1 - 3500 MHz, IF Port = 5 - 1500 MHz