https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Combination of pluggable type 2 arrester and residual current circuit breaker (RCD switch) for 3-phase power supply networks (5-conductor system: L1, L2, L3,N, PE). Product Features Combination of type 2 surge arrester and RCD residual current device Personal protection and device protection in a single device Residual current device is not triggered by magnetic influences caused by discharge currents in the type 2 arrester Optical, mechanical status indication for all protective plugs Disconnect device on each individual plug For 5-conductor systems; L1, L2, L3, N, PE Type 2 consistent plug-in surge arresters Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 840.0 GRM Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 90 mm Width 121 mm Depth 76 mm Ambient conditions Degree of protection IP20 10/23/2014 Page 1 / 7 https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Technical data Ambient conditions Ambient temperature (operation) -25 C ... 40 C Ambient temperature (storage/transport) -40 C ... 60 C General IEC power supply system TT TN-S Housing material PBT / PA Inflammability class according to UL 94 V0 Color light gray Standards for air and creepage distances IEC 61643-1 IEC 60664-1 Mounting type DIN rail: 35 mm Type DIN rail module, two-section, divisible Number of positions 4 Surge protection fault message Optical Direction of action 3L-N & N-PE Protective circuit IEC test classification II T2 EN type T2 Nominal voltage UN 240 V AC (230/400 V AC ... 240/415 V AC) 415 V AC (L-L) Maximum continuous operating voltage UC (L-N) 350 V AC Maximum continuous operating voltage UC (N-PE) 264 V AC UT (TOV-proof) 415 V AC (5 s) 1200 V AC (200 ms / N-PE) Nominal frequency fN 50 Hz 60 Hz Rated load current IL 40 A Residual current IPE 1 A Standby power consumption PC 90 mVA Max. discharge current Imax (8/20) s maximum (L-N) 90 kA (all channels) 30 kA Max. discharge current Imax (8/20) s maximum (N-PE) 30 kA Nominal discharge current In (8/20) s (L-N) 60 kA (all channels) 20 kA Nominal discharge current In (8/20) s (N-PE) 20 kA 10/23/2014 Page 2 / 7 https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Technical data Protective circuit Front of wave sparkover voltage at 6 kV (1.2/50) s (N-PE) 1.7 kV Voltage protection level Up (L-N) 2 kV Voltage protection level Up (N-PE) 2 kV Residual voltage (L-N) 1.8 kV (at In) 1.5 kV (at 10 kA) 1.2 kV (at 5 kA) 1 kV (at 3 kA) Residual voltage (L-PE) 2.5 kV (at In) 2 kV (at 10 kA) 1.4 kV (at 5 kA) 1.1 kV (at 3 kA) Residual voltage (N-PE) 0.7 kV (at In) 0.4 kV (at 10 kA) 0.3 kV (at 5 kA) 0.2 kV (at 3 kA) Response time (L-N) 25 ns Response time (L-PE) 100 ns Response time (N-PE) 100 ns Connection, protective circuit Connection name Protective ground connection Connection method Screw connection Connection type IN Biconnect screw terminal block Connection type OUT Biconnect screw terminal block Connection method Biconnect terminal block Screw thread M5 Tightening torque 4.5 Nm Stripping length 16 mm Conductor cross section stranded min. 4 mm Conductor cross section stranded max. 16 mm Conductor cross section solid min. 4 mm Conductor cross section solid max. 16 mm Conductor cross section AWG/kcmil min. 12 Conductor cross section AWG/kcmil max 4 Connection name Connection protective circuit Connection method Screw connection Connection type IN Biconnect screw terminal block 10/23/2014 Page 3 / 7 https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Technical data Connection, protective circuit Connection type OUT Biconnect screw terminal block Connection method Biconnect terminal block Screw thread M5 Tightening torque 4.5 Nm Stripping length 16 mm Conductor cross section stranded min. 4 mm Conductor cross section stranded max. 25 mm Conductor cross section solid min. 4 mm Conductor cross section solid max. 25 mm Conductor cross section AWG/kcmil min. 12 Conductor cross section AWG/kcmil max 2 Standards and Regulations Standards/regulations IEC 61643-1 2005 EN 61643-11 2002 IEC 61008-1 2004 IEC 61008-1/A11 2007 IEC 61008-2-1 2000 IEC 60947-3 2005 RCD switch Dimensioning error current 30 mA Rated making and breaking capacity Im 1.5 kA Rated residual making and breaking capacity Im 2.5 kA Surge withstand capability 6 kV (1.2/50 s) Immunity to short-circuiting Inc 10 kA (Back-up fuse: 63 A) Tripping time for In 300 ms Tripping time for 5xIn 40 ms Cycles, max. 20000 Utilization category AC 23 A Class A Insulation voltage Ui 440 V Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 10/23/2014 Page 4 / 7 https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Classifications eCl@ss eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130805 eCl@ss 7.0 27130805 eCl@ss 8.0 27130805 ETIM ETIM 2.0 EC000941 ETIM 3.0 EC000941 ETIM 4.0 EC000941 ETIM 5.0 EC000941 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals KEMA-KEUR / VDE Zeichengenehmigung / OVE / GOST / CCA / IECEE CB Scheme Ex Approvals Approvals submitted Approval details KEMA-KEUR 10/23/2014 Page 5 / 7 https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Approvals VDE Zeichengenehmigung OVE GOST CCA IECEE CB Scheme Drawings Connection diagram Functional drawing N N F N 0 off 1 on N N RCD Type A white o.k. IN N N L N L L red fault PE IN 10/23/2014 Page 6 / 7 https://www.phoenixcontact.com/us/products/2882802 Type 2 surge arrester - VAL-CP-RCD-3S/40/0.03 - 2882802 Functional drawing VALVETRAB Functional drawing VALVETRAB green red Functional drawing Functional drawing N 1 on => ok N Dimensioned drawing Circuit diagram 90 N 2 4 6 T PE 76 N 1 3 5 Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 10/23/2014 Page 7 / 7