Inductive sensor NBN15-M1K-WS
Release date: 2011-07-22 15:53 Date of issue: 2012-02-03 030739_eng.xml
Germany: +49 621 776-4411
Subject to modifications without notice
Pepperl+Fuchs Group
fa-info@pepperl-fuchs.comwww.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
Model Number
NBN15-M1K-WS
Features
• 15 mm not embeddable
•2-wire AC
Connection
Accessories
MH 04-3742A
Mounting aid for VariKont and -M1K-
BN
L
N
BU
Dimensions
Technical Data
General specifications
Switching element function AC NO
Rated operating distance sn15 mm
Installation not embeddable
Output polarity AC
Assured operating distance sa0 ... 12.15 mm
Reduction factor rAl 0.43
Reduction factor rCu 0.41
Reduction factor r304 0.82
Nominal ratings
Operating voltage UB20 ... 253 V AC
Switching frequency f 0 ... 20 Hz
Hysteresis H typ. 5 %
Voltage drop Ud≤ 8 V
Momentary current
(20 ms, 0.1 Hz)
0 ... 2400 mA
Operating current IL5 ... 400 mA
Off-state current Ir0 ... 1.7 mA typ.
Operating voltage display LED, green
Indication of the switching state LED, yellow
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type screw terminals
Core cross-section ≤ 2.5 mm2
Housing material PBT
Sensing face PBT
Protection degree IP67
Note 1) In the temperature range below 0 °C, permissible operating vol-
tage Ub 80...253 V
Safety fuse ≤ 2 A (quick-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is
functioning correctly.
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
15
4,3x5,3
LEDs
30
30
41
91
20/22
M16 x 1,5