ENET
Data Layer Decode
Key Features
Ethernet Data Layer Decode for
10BASE-T and 100BASE-TX
Color-coded decode highlights
key elements of Ethernet
packet such as address or error
information
Decoded information is
intuitively overlaid directly on
top of the waveform
Decode information expands
as the timebase is adjusted or
zoomed
Convenient table display with
quick “zoom to message”
capability
Quick search capability for
specific Ethernet frames
Decode Annotation
Complements Physical
Layer Views
The Ethernet 10BASE-T and
100BASE-TX protocol information is
decoded and displayed on the physical
layer waveform. Various sections
of the protocol, such as Destination
and Source Address or CRC Errors,
are color-coded to make it easy to
understand. Decode annotation
information condenses or expands
depending on the timebase/zoom
ratio setting. The decode operation
is fast—even with long acquisitions.
Data transferred in a frame is not only
displayed on the frame level but also
on individual byte level. Look at the
big picture while focusing on details
at the same time.
Decode annotation provides the
ability to view protocol traffic on the
oscilloscope and verify that the link
is alive and transmitting properly
as it quickly decodes waveform
data instantaneously. It also aids in
debugging problems that are not
solely analog or digital in nature, such
as interoperability issues, uncertain
error causes, and physical layer issues
not evident with a protocol analyzer.
Convenient Table Display
and Search
Long oscilloscope acquisition memory
provides long capture times of
Ethernet transmissions. Decoded
information is conveniently shown in
an interactive table, any table entry
can be selected for a closer look. The
search capabilities help identify and
isolate protocol specifics such as CRC
errors, data size errors and more. In
addition, table data may be exported
as .csv files for offline analysis.
Support on Multiple
Oscilloscope Platforms
The Ethernet 10BASE-T and
100BASE-TX decode option is
available on a wide range of
oscilloscope models with real-time
bandwidths from 200 MHz to 65 GHz.
Ethernet decoding provides protocol awareness to the oscilloscope for fast debugging.
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our
digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes:
No charge for return shipping
Long-term 7-year support
Upgrade to latest software at no charge
© 2013 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
enet-decode-ds-19feb13
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.
1-800-5-LeCroy
teledynelecroy.com
ENET
Definition
Protocol Setup Selection for source channels. Supports Single (differential probe) or dual (two single-ended probes) input(s) for decoder.
Detects auto negotiation (option for 100BASE-TX).
Decode Capability
Format Ethernet 10BASE-T and 100BASE-TX Protocol Decode (Hexadecimal).
Decode Setup Selection for source inputs.
Decode Input Any analog Channel, Memory or Math trace.
# of Decode
Waveforms
Up to 4 unique lanes may be decoded at one time.
In addition, zooms can be displayed (with decoded information).
Location Overlaid over waveform, on Grid
Visual Aid Color Coding for Frame, Group Primitives, Data words, Primitive words, and important frame fields such as address and Ethernet
type. Decode information is intelligently annotated based on timebase setting.
Search Capability
Pattern Search Search by the following: Any, Frame, Idle, Source Address, Destination Address, FLP Burst, Electrical Idle,
Protocol Errors: Any, Missed Terminate, Missed Start of Frame, Frame Length Error, Preamble Value Error, Start of Frame,
Delimiter Value Error, CRC Error, Data Size Error
Other
Compatible
With...
Fully compatible with HDO6000, HDO4000, WaveSurfer® Xs/Xs-A/Xs-B Series, WaveRunner® 6 Zi Series,
WaveRunner® Xi/Xi-A Series, WavePro® 7 Zi/Zi-A Series, WaveMaster® 8 Zi/Zi-A Series, LabMaster 9Zi-A Series,
and LabMaster 10Zi Series. Bandwidth of oscilloscope must be equal to bit rate with a minimum oscilloscope sample rate
of 4x the bit rate.
SPECIFICATIONS AND ORDERING INFORMATION
Product Description Product Code
ENET Decode Options
ENET Decode Option for HDO4000 HDO4K-ENETbus D
ENET Decode Option for HDO6000 HDO6K-ENETbus D
ENET Decode Option for WaveSurfer Xs/Xs-B WSXs-ENETbus D
ENET Decode Option for WaveRunner 6 Zi WR6Zi-ENETbus D
ENET Decode Option for WaveRunner Xi/Xi-A WRXi-ENETbus D
ENET Decode Option for WavePro 7 Zi/Zi-A WPZi-ENETbus D
ENET Decode Option for WaveMaster 8 Zi-A WM8Zi-ENETbus D
ENET Decode Option for LabMaster 9 Zi-A LM9Zi-ENETbus D
ENET Decode Option for LabMaster 10 Zi LM10Zi-ENETbus D
Product Description Product Code
Recommended Accessories
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V ZD200
500 MHz, 1.0 pF Active Differential Probe, ±8 V ZD500
1 GHz, 1.0 pF Active Differential Probe, ±8 V ZD1000
10/100/1000Base-T Compliance Test Fixture TF-ENET-B
Ordering Information
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Teledyne LeCroy: