Specifications
TRG36 Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 50 to 60Hz
Inrush Current ………………….………….................... 60A max. @240Vac
Leakage Current …………………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recover)
Over Voltage Protection …………………………..TVS Component to Clamp
Temperature Coefficient …………………….................................. ±0.05%/℃
GENERAL SPECIFICATIONS:
NOTE:
Isolation …………………………………………… Input to output = 4,242VDC
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Operating Temperature ................................... 0 ~ 60℃(see derating curve)
Ripple & Noise measurement @20MHz BW.
Storage Temperature ………………………………..........……........ -20~85℃
2.Voltage setpoint at 60% load.
Humidity .................................................... 93% RH max. Non condensing
3. Line regulation is measured from 100Vac to 240Vac, full load.
Cooling …………………………………………………..... Natural Convection
4. Load regulation measured from 60% to 100% full load and from 60%
Switching Frequency ……….………………………………….……. 50~70KHz
to 20% load (60% +/- 40% full load).
MTBF ….…… MIL-HDBK-217F, GB, at 25℃/115VAC ……. 200K hrs min.
5. Typical efficiency at 230VAC and full load at 25℃.
Altitude ……………………..……………………………….…………… 2000m
6. ”Various TR Series adapters are PSE certified. PSE certification alone
Dimensions …….….. 4.331x1.969x0.787inches (110.00x50.00x20.00mm)
is not sufficient for importation into Japan. A valid PSE mark must
Weight ……………………………………………………… 190g(0.42 Pounds)
contain the name of the importer as shown in the example below. If PSE
AC Inlet …………………………………………………………….. IEC320/C8
mark is required, the name of the registered importer must be supplied
SAFETY AND EMC:
to Cincon on order placement. Product labels will not contain PSE
Emission and Immunity ………...…. EN55022 Class B, FCC Part 15 Class B
mark if importer name is not supplied. Consult factory or local represent
EN61000-6-3, EN61000-3-2, EN61000-3-
tative for details”.
EN55024, EN61204-3, EN61000-6-1
Safety ……………………………… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
All Dimensions are in inches(mm)
IEC320/C8
DC Plug:Right Angle(ψ5.5/ψ2.5 )L12mm
DC Plug type: V+ ─●)─ V-
18AWG/1800mm
70.866[1800.00]±1.969[50.00]
1.969[50.00]
0.787[20.00]
4.331[110.00]
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
0%
20%
40%
60%
80%
100%
0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)