Isolated and Unregulated 0.75 WATT Modular DC/DC Converters DUP75 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
INPUT SPECIFICATIONS
Input Voltage Ranges: 5 VDC Nominal 4.5-5.5 VDC
12 VDC Nominal 10.8-13.2 VDC
15 VDC Nominal 13.5-16.5 VDC
24 VDC Nominal 21.6-26.4 VDC
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Load Regulation +/- 10% on 5V output
10% - FL +/- 6% on all others
Line Regulation +/- 1.2%/1% of Vin
Temperature Coefficient +/-0.1%/DegC
Ripple/Noise(Single/Dual) 50mV Pk-Pk, typ
Voltage Stability +/-5%, max
Short Circuit Protection 1 Second max
GENERAL SPECIFICATIONS
Input-Out Isolation 750VDC
Efficiency 78%, typ
Switching Frequency 100Khz
Isolation Resistance 10000 M Ohms
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -25 to +71 DegC(FL)
Storage Temperature -55 to +125 DegC *
Maximum Case Temp 110 DegC *
MTBF 5.5 MHrs
MIL-HDBK 217F TA=25C FL
PHYSICAL SPECIFICATIONS
Case Material Non-Conductive Black Plastic
Construction Fully Encapsulated