IR2111(S) & (PbF)
www.irf.com 3
Symbol Definition Min. Typ. Max. Units Test Conditions
VIH Logic “1” input voltage for HO & logic “0” for LO 6.4 — — VCC = 10V
9.5 — — VCC = 15V
12.6 — — VCC = 20V
VIL Logic “0” input voltage for HO & logic “1” for LO — — 3.8 VCC = 10V
— — 6.0 VCC = 15V
— — 8.3 VCC = 20V
VOH High level output voltage, VBIAS - VO— — 100 IO = 0A
VOL Low level output voltage, VO— — 100 IO = 0A
ILK Offset supply leakage current — — 50 VB = VS = 600V
IQBS Quiescent VBS supply current — 50 100 VIN = 0V or VCC
IQCC Quiescent VCC supply current — 70 180 VIN = 0V or VCC
IIN+ Logic “1” input bias current — 30 50 VIN = VCC
IIN- Logic “0” input bias current — — 1.0 VIN = 0V
VBSUV+ VBS supply undervoltage positive going threshold 7.6 8.6 9.6
VBSUV- VBS supply undervoltage negative going threshold 7.2 8.2 9.2
VCCUV+ VCC supply undervoltage positive going threshold 7.6 8.6 9.6
VCCUV- VCC supply undervoltage negative going threshold 7.2 8.2 9.2
IO+ Output high short circuit pulsed current 200 250 — VO = 0V, VIN = VCC
PW ≤ 10 µs
IO- Output low short circuit pulsed current 420 500 — VO = 15 V, V IN = 0V
PW ≤ 10 µs
Static Electrical Characteristics
VBIAS (VCC, VBS) = 15V and TA = 25°C unless otherwise specified. The VIN, VTH and IIN parameters are referenced to
COM. The VO and IO parameters are referenced to COM and are applicable to the respective output leads: HO or LO.
mV
mA
V
V
µA
Symbol Definition Min. Typ. Max. Units Test Conditions
ton T urn-on propagation delay 550 750 950 VS = 0V
toff Turn-off propagation delay — 150 180 VS = 600V
trTurn-on rise time — 80 130
tfTurn-off fall time — 40 65
DT Deadtime, LS turn-off to HS turn-on & 480 650 820
HS turn-off to LS turn-on
MT Delay matching, HS & LS turn-on/off — 30 —
Dynamic Electrical Characteristics
VBIAS (VCC, VBS) = 15V, CL = 1000 pF and TA = 25°C unless otherwise specified. The dynamic electrical characteristics
are measured using the test circuit shown in figure 3.
ns