Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (412) 925-7272
CR03AM
Lead-Mount, Phase Control SCR
0.3 Amperes/400-600 Volts
P-8
Absolute Maximum Ratings, Ta= 25 °C unless otherwise specified
Ratings Symbol CR03AM-8 CR03AM-12 Units
Repetitive Peak Off-state Voltage VDRM 400 600 Volts
Repetitive Peak Reverse Voltage VRRM 400 600 Volts
Non-repetitive Peak Reverse Voltage VRSM 500 720 Volts
DC Reverse Voltage VR(DC) 320 480 Volts
DC Forward Voltage VD(DC) 320 480 Volts
RMS On-state Current IT(RMS) 0.47 0.47 Amperes
Average On-state Current (Nominal, See Graphs) Ta= 47°C IT(avg) 0.3 0.3 Amperes
Non-repetitive Peak Surge, On-state Current One Cycle (60 Hz) ITSM 20 20 Amperes
I2t for Fusing, t = 8.3 msec I2t 1.6 1.6 A2sec
Peak Gate Power Dissipation PGM 0.5 0.5 Watts
Average Gate Power Dissipation PG(avg) 0.1 0.1 Watts
Peak Forward Gate Current IFGM 0.3 0.3 Amperes
Peak Forward Gate Voltage VFGM 6 6 Volts
Peak Reverse Gate Voltage VRGM 6 6 Volts
Storage Temperature Tstg -40 to 125 -40 to 125 °C
Operating Temperature Tj-40 to 125 -40 to 125 °C
Weight – 0.23 0.23 Grams
Electrical and Thermal Characteristics, Tj= 25 °C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Voltage – Blocking State
Peak Forward Leakage IDRM Tj= 110°C, VD= VDRM – – 0.1 mA
Peak Reverse Leakage IRRM Tj= 110°C, VR= VRRM – – 0.1 mA
Current – Conducting State
Peak On-state Voltage VTM Ta= 25°C, ITM = 4 A Peak – – 1.8 Volts
DC Holding Current IH VD= 12V, RGK = 1KV, Tj= 25°C – 1.5 3.0 mA
Thermal Resistance,
Junction-to-ambient Rth(j-a) – – – 180 °C/W
Gate – Parameters
Gate Current to Trigger†IGT VD= 6V, RL= 60V, Tj= 25°C 1 – 100 mA
Gate Voltage to Trigger†VGT VD= 6V, RL= 60V, Tj= 25°C – – 0.8 Volts
Non-triggering Gate Voltage VGDM VD= 1/2VDRM, RGK = 1kV, Tj= 110°C 0.2 – – Volts
† IGT, VGT Measurement Circuit