Product data sheet Characteristics TM241C40U controller M241 40 IO transistor NPN Commercial Status Commercialised Range of product Modicon M241 Product or component type Logic controller Discrete input number 24 discrete input including 8 fast input conforming to IEC 61131-2 Type 1 Discrete output type Transistor Discrete output number 16 transistor including 4 fast output Discrete output voltage 24 V DC for transistor output Discrete output current 0.5 A with Q0...Q15 terminal(s) for transistor output 0.1 A with Q0...Q3 terminal(s) for fast output (PTO mode) [Us] rated supply voltage 24 V DC Complementary Discrete I/O number 40 Discrete input logic Sink or source Discrete input voltage 24 V Discrete input voltage type DC Voltage state1 guaranteed >= 15 V for input Current state 1 guaranteed >= 5 mA for fast input >= 2.5 mA for input Voltage state 0 guaranteed <= 5 V for input Current state 0 guaranteed <= 1.5 mA for fast input <= 1 mA for input Discrete input current 7 mA for input 10.7 mA for fast input Input impedance 2.81 kOhm for fast input 4.7 kOhm for input Response time <= 250 s turn-off operation with Q0...Q15 terminal(s) for output <= 34 s turn-on operation with Q0...Q15 terminal(s) for output 50 s turn-off operation with I0...I15 terminal(s) for input 50 s turn-on operation with I0...I15 terminal(s) for input <= 2 s turn-off operation with Q0...Q3 terminal(s) for fast output <= 2 s turn-on operation with Q0...Q3 terminal(s) for fast output <= 2 s turn-off operation with I0...I7 terminal(s) for fast input <= 2 s turn-on operation with I0...I7 terminal(s) for fast input Configurable filtering time 12 ms for input 4 ms for input 1 ms for input 0 ms for input 12 ms for fast input 1 s for fast input Number of I/O expansion module 14 (remote I/O architecture) 7 (local I/O architecture) Discrete output logic Negative logic (sink) Output voltage limits 30 V Output frequency <= 1 kHz for output <= 100 kHz for fast output (PLS mode) <= 20 kHz for fast output (PWM mode) Aug 28, 2015 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main Accuracy +/- 1 % at 100 Hz...1 kHz for fast output +/- 0.1 % at 20...100 Hz for fast output Leakage current <= 5 A for output Voltage drop <= 1 V Tungsten load <= 2.4 W Protection type Reverse polarity protection for fast output Short-circuit and overload protection with automatic reset Short-circuit protection Reset time 12 s fast output 10 ms output Current per output common 2A Execution time for 1 KInstruction 0.7 ms for other instruction 0.3 ms for event and periodic task Memory capacity 64 MB for system memory RAM 8 MB for program Data backed up 128 MB built-in flash memory for backup of user programs Data storage equipment <= 32 GB SD card optional Battery type BR2032 lithium non-rechargeable, battery life: 4 yr Backup time 2 years at 25 C Application structure 8 event tasks 4 cyclic master tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks Realtime clock With Clock drift <= 60 s/month at 25 C Positioning functions PWM/PTO function 4 channel(s) (positioning frequency: 100 kHz) Control signal type Single phase signal at 200 kHz for fast input (HSC mode) Pulse/Direction signal at 200 kHz for fast input (HSC mode) A/B signal at 100 kHz for fast input (HSC mode) Counting input number 4 fast input (HSC mode) Integrated connection type USB port with connector mini B USB 2.0 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Supply Serial link supply "serial 1" at 5 V, 200 mA Transmission rate 480 Mbit/s for bus length of 3 m - communication protocol: USB 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485 Communication port protocol Modbus non isolated serial link with master/slave method Supply voltage limits 20.4...28.8 V Inrush current <= 50 A Power consumption in W 32.6...40.4 W Cable length <= 3 m shielded cable for fast output <= 50 m unshielded cable for output <= 10 m shielded cable for fast input <= 50 m unshielded cable for input Local signalling 1 LED per channel green for I/O state 1 LED red for bus fault on TM4 (TM4) 1 LED green for SL2 1 LED green for SL1 1 LED red for BAT 1 LED green for SD card access (SD) 1 LED red for I/O error (I/O) 1 LED red for module error (ERR) 1 LED green for RUN 1 LED green for PWR Electrical connection Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) Removable screw terminal block for inputs and outputs (pitch 5.08 mm) 2 Insulation 500 V AC between output groups 500 V AC between fast output and internal logic Non-insulated between outputs 500 V AC between output and internal logic 500 V AC between fast input and internal logic Non-insulated between inputs 500 V AC between input and internal logic Non-insulated between supply and ground 500 V AC between supply and internal logic Marking CE Surge withstand 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 1 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 Mounting support Plate or panel with fixing kit Top hat type TH35-7.5 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715 Height 3.54 in (90 mm) Depth 3.74 in (95 mm) Width 7.48 in (190 mm) Product weight 1.37 lb(US) (0.62 kg) Environment Standards CSA C22.2 No 142 UL 1604 UL 508 ANSI/ISA 12-12-01 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) Product certifications CSA CULus IACS E10 RCM Resistance to electrostatic discharge 4 kV on contact conforming to EN/IEC 61000-4-2 8 kV in air conforming to EN/IEC 61000-4-2 Resistance to electromagnetic fields 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 Resistance to fast transients 1 kV for transistor output conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 2 kV for power lines conforming to EN/IEC 61000-4-4 Resistance to conducted disturbances, induced by radio frequency fields 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) 3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Electromagnetic emission Radiated emissions, test level: 47 dBV/m QP with class A (radio frequency: 230 MHz...1 GHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBV/m QP with class A (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 63 dBV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBV/m QP, condition of test: power lines (radio frequency: 150 kHz...1.5 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 120...69 dBV/m QP, condition of test: power lines (radio frequency: 10...150 kHz) conforming to EN/IEC 55011 Immunity to microbreaks 10 ms Ambient air temperature for operation -10...55 C for horizontal installation -10...50 C for vertical installation Ambient air temperature for storage -13...158 F (-25...70 C) Relative humidity 10...95 % without condensation in storage 10...95 % without condensation in operation 3 IP degree of protection IP20 with protective cover in place Pollution degree 2 Operating altitude 0...6561.68 ft (0...2000 m) Storage altitude 0...9842.52 ft (0...3000 m) Vibration resistance 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail Shock resistance 15 gn for 11 ms Offer Sustainability Sustainable offer status RoHS 4 Not Green Premium product Compliant - since 1330 - Schneider Electric declaration of conformity