1
CSM_E3C_DS_E_8_1
Compact Head Amplifier-separated Photoelectric Sensor
E3C
Thin, Compact Head Saves Space
and Mounts Closely. Built-in
Interference Protection Provided.
Input indicator on the Sensor Unit simplifies settings.
Be sure to read Safety Precautions on
page 11.
Ordering Information
Sensors
Sensor Units [Refer to Dimensions on page 12.]
* Through-beam Sensors are normally sold in sets that include both the Emitter and Receiver.
Orders for individual Emitters and Receivers are accepted. (Modifications are required for some models. Ask your OMRON representative for details.)
Sensing method Application Appearance Sensing distance Model
Through-beam
(Emitter + Receiver) *
Small type
E3C-S10 2M
Emitter E3C-S10L 2M
Receiver E3C-S10D 2M
E3C-S50 2M
Emitter E3C-S50L 2M
Receiver E3C-S50D 2M
E3C-1 2M
Emitter E3C-1L 2M
Receiver E3C-1D 2M
E3C-2 2M
Emitter E3C-2L 2M
Receiver E3C-2D 2M
Slim type
E3C-S20W 2M
Emitter E3C-S20LW 2M
Receiver E3C-S20DW 2M
E3C-S30W 2M
Emitter E3C-S30LW 2M
Receiver E3C-S30DW 2M
Side-view
E3C-S30T 2M
Emitter E3C-S30LT 2M
Receiver E3C-S30DT 2M
Diffuse-reflective
Small type E3C-DS10 2M
Slim type E3C-DS5W 2M
Side-view E3C-DS10T 2M
Convergent-reflective Small type E3C-LS3R 2M
Red light Infrared light
10
12
5.8
100 mm
11
13
7
500 mm
25
8
12
1 m
36
16
12.4
2 m
18
12.5
2.8
200 mm
15
8
3
300 mm
7.85
3
15
15
26
10
100 mm
18
19.5
2.8
50 mm
8
21
11
100 mm
10
18
36
30±3 mm
E3C
2
Amplifier Units [Refer to Amplifier Units on page 15.]
Accessories (Order Separately)
Mounting Brackets [Refer to E39-L/F39-L/E39-S/E39-R for Dimensions.]
Note: Refer to E39-L/F39-F/E39-S/E39-R for Dimensions.
* When using through-beam models, order one bracket for the Receiver and one for the Emitter.
Connector [Refer to E39-L/F39-L/E39-S/E39-R for Dimensions.]
Power supply Application Appearance Functions Model
AC Standard models
--- E3C-A
E3C-C
DC
Slim type E3C-JC4P 2M
Small type --- E3C-GE4
49
48 109.5 Timer
60
30
14
Self
dia
g
nostic
35.5
27.2
20.7
Appearance Model Quantity Remarks
E39-L41 2 Provided with the E3C-1.
E39-L42 2Provided with the E3C-2.
Can be used with the E3C-DS10.
E39-L127-T1 1
Can be used with the E3C-S10.E39-L127-T2 1
E39-L127-T3 1
E39-L31 1*Can be used with the E3C-S50.
Name Appearance Model Quantity Remarks
Front connection
socket
PF113A 1 Provided with the E3C-A/C.
PYF08A 1 Can be used with the E3C-GE4.
Rear connection
socket PY08 1 Can be used with the E3C-GE4.
E3C
3
Ratings and Specifications
Sensors
Sensing method Through-beam
Item Model E3C-S10 E3C-S20W E3C-S50 E3C-S30T
E3C-S30W E3C-1 E3C-2
Sensing distance 100 mm 200 mm 500 mm 300 mm 1 m 2 m
Standard sensing
object Opaque, 2-mm dia. min. Opaque, 3-mm
dia. min.
Opaque, 1.5-mm
dia. min.
Opaque, 4-mm
dia. min.
Opaque, 8-mm
dia. min.
Directional angle Emitter/Receiver: 10 to 60° each Emitter/Receiver: 10 to 40° each Emitter/Receiv-
er: 3 to 20° each
Emitter/Receiv-
er: 3 to 15° each
Light source (wavelength) Infrared LED (950 nm) Infrared LED
(940 nm) Infrared LED (950 nm)
Ambient illuminance
(Receiver side) Incandescent lamp: 3,000 lx max., Sunlight 10,000 lx max.
Ambient temperature range Operating/Storage: 25°C to 70°C (with no icing or condensation)
Ambient humidity range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 500 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP64
Limited to indoor
use
IEC 60529 IP50
Limited to indoor
use
IEC 60529 IP64
Limited to indoor
use
IEC 60529 IP60
Limited to indoor
use
IEC 60529 IP66
Limited to indoor use
Connection method Pre-wired models (standard length: 2 m)
Weight (packed state) Approx. 50 g Approx. 24 g Approx. 60 g Approx. 120 g
Material
Case Polycarbonate ABS Polycarbonate Zinc die-cast
Lens Polycarbonate Acrylics Polycarbonate
Mounting
Brackets --- Steel
Accessories Instruction
manual
Phillips screw
M2×8, spring
washer, flat
washer, M2 nut,
instruction
manual
Instruction
manual
Phillips screw
M2×8, spring
washer, flat
washer, nut M2,
instruction
manual
Mounting
Bracket (with
screws),
instruction
manual
Mounting
Bracket (with
screws),
instruction
manual
Sensing method Diffuse-reflective Convergent-reflective
Item Model E3C-DS5W E3C-DS10T E3C-DS10 E3C-LS3R
Sensing distance 50 mm (White paper 100 ×
100 mm)
100 mm (White paper 100
× 100 mm)
100 mm (White paper 50 ×
50 mm)
30 ± 3 mm (White paper 10
× 10 mm)
Differential travel 20% max. of sensing distance 10% max. ±3% max.
Light source (wavelength) Infrared LED (950 nm) Infrared LED (950 nm) Red LED (680 nm)
Ambient illuminance
(Receiver side) Incandescent lamp: 3,000 lx max., Sunlight 10,000 lx max.
Ambient temperature range Operating/Storage: 25°C to 70°C (with no icing or condensation)
Ambient humidity range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 500 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP50 (Limited to indoor use) IEC 60529 IP64 (Limited to indoor use)
Connection method Pre-wired models (standard length: 2 m)
Weight (packed state) Approx. 50 g Approx. 55 g
Material Case Polycarbonate
Lens Polycarbonate
Accessories
Phillips screw M2×8,
spring washer, flat washer,
M2 nut, instruction manual
Instruction manual
E3C
4
Amplifier Units
* The terminal pins are used for connection between amplifiers for synchronous operation.
Item Model E3C-A E3C-C E3C-JC4P E3C-GE4
Power supply
voltage 100 to 240 VAC±10%, 50/60 Hz 12 to 24 VDC±10%, ripple (p-p): 1 V max.
Power (current)
consumption 3 W max. 50 mA max.
Control
output
Transis-
tor
output
Load power supply voltage: 24 VDC max., load current: 80 mA
max., voltage output type, output current: 1 to 4 mA (residual
voltage: 1.2 V max.)
Light-ON/Dark-ON switch selectable
Load power supply voltage: 24
VDC max., load current: 100
mA max., NPN open collector
output type (residual voltage:
1 V max.)
Light-ON/Dark-ON switch se-
lectable
Load power supply voltage: 24
VDC max., load current:
80 mA max., voltage output
type, output current: 1 to 4 mA
(residual voltage: 0.7 V max.)
Light-ON/Dark-ON cable con-
nection selectable
Relay out-
put
220 VAC 1 A cosφ=1
(resistive load)
SPDT contact only
---
External
synchronous input ---
H = 6 to 30 V
L = 0 to 2 V
When L, turns OFF the control
output forcibly.
---
Timer function --- ON/OFF, oneshot delay (se-
lectable): 1 or 10 s max.
OFF-delay 0/40 ms (switch se-
lectable) ---
Ambient
temperature range Operating:10° to 55°C, Storage: 25° to 70°C (with no icing or condensation)
Ambient humidity
range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 500 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 300 ms2 three times in each of X, Y and Z directions
Degree of protection IEC IP20
(limited to indoor use)
IEC IP60
(limited to indoor use)
IEC IP20
(limited to indoor use)
Protection Reverse polarity protection, output short-circuit protection, mutual interference prevention
Response
time
No
contact
Operate or reset: 1 ms max./2 ms max. each (switch select-
able) Operate or reset: 1 ms max.
Operate or reset: 1 ms max./2 ms
max. each (switch selectable)
Relay Operate or reset: 20 ms max. ---
Connection method Terminal block
Terminal block input cable
pullout
(standard cable length: 2 m)
Terminal block
Weight
(packed state) Approx. 200 g Approx. 80 g Approx. 15 g
Material
Case ABS Polycarbonate
Mounting
Brackets Stainless steel --- Iron ---
Accessories Connection Socket (PF113A)
Instruction manual
Mounting Bracket, Adjustment
screwdriver, Caution label,
Instruction manual
Instruction manual
E3C
5
Engineering Data (Typical)
Parallel Operating Range
Through-beam Through-beam Through-beam
E3C-S10 E3C-S20W E3C-S50
Through-beam Through-beam Through-beam
E3C-1 E3C-2 E3C-S30T/-S30W
Operating Range
Diffuse-reflective Diffuse-reflective Diffuse-reflective
E3C-DS5W E3C-DS10T E3C-DS10 (Example 1)
Y
X
200
150
100
50
0
50
100
150
200
Sensing
distance X (mm)
50 100 150 200 250 300
Operating position Y (mm)
Y
X
200
150
100
50
0
50
100
150
200
50 100 150 200 250 300
Sensing
distance X (mm)
Operating position Y (mm)
Y
X
0.2 0.4 0.6 0.8
1
200
150
100
50
0
50
100
150
200
Sensing
distance X (mm)
Operating position Y (mm)
Y
X
0.5 1 1.5 2
200
150
100
50
0
50
100
150
200
Sensing
distance X (mm)
Operating position Y (mm)
Y
X
200
150
100
50
0
50
100
150
200
1 2 3 4
Sensing
distance X (mm)
Operating position Y (mm)
200
150
100
50
0
50
100
150
200
200 400 600 800
Y
X
Sensing
distance
X (mm)
Operating position Y (mm)
Moving direction
of object
X
Y
40
30
20
10
0
10
20
30
40
20 40 60 80 120
100
Sensing
distance
X (mm)
Operating position Y (mm)
Y
X
40
30
20
10
0
10
20
30
40
20 40 60 80 100 120 160
140
Sensing
distance
X (mm)
Operating position Y (mm)
X
Optical
axis
Y
40
30
20
10
0
10
20
30
40
40 80 120 200
160
ON
OFF
Moving
direction
of object
Sensing
distance
X (mm)
Operating position Y (mm)
E3C
6
Diffuse-reflective Convergent-reflective Convergent-reflective
E3C-DS10 (Example 2) E3C-LS3R (Example 1) E3C-LS3R (Example 2)
Excess Gain vs. Set Distance
E3C-S20W E3C-S30T/-S30W E3C-S50
E3C-DS5W E3C-DS10T E3C-LS3R
X
Y
40
30
20
10
0
10
20
30
40
40 80 120
160
200
ON
OFF
Optical
axis
Moving direction
of object
Sensing
distance
X (mm)
Operating position Y (mm)
X
Y
2
1
0
1
2
22 26 28 30 32 34 36 38
ON
OFF
24
Optical
axis
Sensing distance
X (mm)
Operating position Y (mm)
Moving direction
of object
X
Y
2
1
0
1
2
22 26 28 30 32 34 3836
ON
OFF
24
Optical
axis
Moving
direction
of object
Sensing distance
X (mm)
Operating position Y (mm)
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.1
0 100 200 300 400 500
Set distance (mm)
Operating Level
Excess Gain ratio
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.1
0 0.2 0.4 0.6 0.8 1
Excess Gain ratio
Operating Level
Set distance
(
mm
)
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.1
0 0.2 0.4 0.6 0.8
1
Excess Gain ratio
Operating Level
Set distance
(
mm
)
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.1
0 50 100 150 200
Excess Gain ratio
Operating Level
Set distance (mm)
0 50 100 150 200
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.1
Excess Gain ratio
Operating Level
Set distance (mm)
100 20304050
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.1
Excess Gain ratio
Operating Level
Set distance (mm)
E3C
7
I/O Circuit Diagrams
NPN output
* For t in the timing chart, refer to Part Names/Selection Method on page 9.
Model Operation
mode Timing charts *Operation
selector Output circuit
E3C-A
E3C-C
Light-ON LIGHT ON
Dark-ON DARK ON
E3C-JC4P
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
E3C-GE4
Light-ON
Switched with
wiring.
(LIGHT ON)
Dark-ON
Switched with
wiring.
(DARK ON)
Incident light
No incident light
ON
OFF
a
b
H
L
ON
OFF
Light
indicator
(red)
Contact
output
Solid-state
output
Output
transistor
tt
Output
0 V
+12 V
+5.5 V
Output circuitInput circuit
Synchronous
inputs * 1
Rated current
circuit
1.5 to 4 mA
80 mA max.
*2
3
2
9
HIGH 6 to 30 V
LOW 0 to 2 V
* 1. E3C-C only
* 2. E3C-A/-C have SPDT contact output.
(About terminal number, please refer to the connection section.)
Photo-
electric
Sensor
Main
Circuit
tt
Incident light
No incident light
ON
OFF
a
b
H
L
ON
OFF
Light
indicator
(red)
Contact
output
Solid-state
output
Output
transistor
Incident light
No incident light
ON
OFF
ON
OFF
ON
OFF
Light
indicator
(red)
Output
transistor
Load
(relay etc.)
40 ms
Light
indicator
(red)
Stability
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Load
Brown
Black
Blue
Pink
Self diagnostic output
50 mA max.
Output
12 to 24 VDC
0 V
100 mA max.
Z
0
Z
1
40 ms
Incident light
No incident light
ON
OFF
ON
OFF
ON
OFF
Light
indicator
(red)
Output
transistor
Load
(relay etc.)
Incident light
No incident light
ON
OFF
H
L
ON
OFF
Light
indicator
(red)
No-contact
output
Output
transistor
tt
14 4
+Output
Rated current
circuit
1.5 to 4 mA
80 mA max.
12
14
4
Power
source
Photo-
electric
Sensor
Main
Circuit
tt
Incident light
No incident light
ON
OFF
H
L
ON
OFF
Light
indicator
(red)
No-contact
output
Output
transistor
14 4
+
E3C
8
Connection
Amplifier Units Connected to the through-beam model Connected to the reflective model Note
E3C-A/C
+
PF113A
Note: 1. The strip-off length of the
shielded cable should
always be 20 mm max. on
the Receiver side (white)
and 50 mm max. on the
Emitter side (red).
2. The E3C-A does not have
a gate input function.
3. L when the gate input 2-9
terminals are connected,
H when they are
disconnected.
E3C-JC4P
Note: 1. The strip-off length of the
shielded cable should
always be 20 mm max. on
the Receiver side (white)
and 50 mm max. on the
Emitter side (red).
E3C-GE4
Note: 1. The strip-off length of the
shielded cable should
always be 20 mm max. on
the Receiver side (white)
and 50 mm max. on the
Emitter side (red).
2. The response time is 1 ms
when (8) is disconnected,
and 2 ms when (8) is
connected to 0 V (negative
side) of the power supply.
3. By setting the power
supply terminal (4) to
and (14) to +, the output
turns "H" when the light is
received. With the E2
mode, the output transistor
turns OFF. By setting (4)
to + and (14) to +, the
output turns "L" when the
light is received. With the
E1 mode, the output
transistor turns ON.
Emitter Receiver
ShieldRed
White
Gate input
(Note)
Solid-state output
+
+
Tb Ta Tc 100 to 240 VAC
Shield
2 1 11 10
5678
93
4
E3C-A/C
Emitter/receiver
White
Red
E3C-A/C
Gate input
(Note
)
Solid-state output
+
+
Tb Ta Tc 100 to 240 VAC
2 1 11 10
5678
93
4
Shield
Shield
Shield
Emitter Receiver
White
Red
Shield
Emitter/receive
r
Shield
White
Red
Shield
1
5
9
13
4
8
12
14
Red
White
Shield
Shield
Emitter
Receiver
Response
time
selector
input
12 to
24 VD
C
Output
+
+
1
5
9
13
4
8
12
14
Emitter/
receiver
Response
time
selector
input
Shield
Red
Shield
White
12 to
24 VDC
Output
+
+
E3C
9
Nomenclature/Settings
Amplifier Units Nomenclature Settings
E3C-A
E3C-C
Stability indicator (green)
When the light receiving input
becomes +20% or more and 20%
or less of operating voltage, it will
be turned on. (Indicate stable status)
Light indicator
(red)
When the light
inputs,
it will be turned on.
Sensitivity adjuster
Response
time
selector
switch
Operation
selector
Operation
indicator (red)
When a relay-switch
operates, the indicator turns
on.
Operation switching
Response time changing (The different frequency type can be
made up by changing the response speed.)
Timing chart
DARK turns the relay ON and the transistor out-
put "H".
LIGHT turns the relay ON and the transistor out-
put "H".
The response time is set to 2 ms.
The response time is set to 1 ms.
DARK ON LIGHT ON
DARK ON LIGHT ON
2 ms (B) 1 ms (A)
2 ms (B) 1 ms (A)
Note 1. Control output is produced only during input time.
2. When t exceeds 1 ms or 2 ms, solid-state output is produced.
To produce relay output, t must be longer than 20 ms.
tt
Incident light
No incident light
"a"
"b"
"a"
"b"
"H"
"L"
"H"
"L"
(OFF)
(ON)
(OFF)
(ON)
(Output
transistor)
Relay
Output
Solid
state
Selector switch for
operating mode
LIGHT ON
Selector switch for
operating mode
DARK ON
Stability indicator (green)
When the light receiving input
becomes +20% or more and 20%
or less of operating voltage, it will be
turned on. (Indicate stable status)
Light indicator
(red)
When the light
inputs,
it will be turned on.
Sensitivity adjusterDelay time adjuster
Delay
time setting
switch
Timer
function
setting
switch
Selector
switch for
response
time
Operation
selector
Operation indicator
(red)
When a relay-switch
operates, the indicator turns
on.
Operation switching
Response time changing (The different frequency type can be
made up by changing the response speed.)
Delay time setting
After setting the selector, fine-adjust the delay time with the
variable adjuster. (Clockwise turn increases the delay time.)
Timing chart
External synchronous input operation
When the external synchronous input terminal (9) is open (HIGH), the output
relay performs timer operation according to the input signals (LIGHT, DARK).
When the external synchronous input terminaL (9) is connected to the 0 V ter-
minal (2) (LOW), the output relay turns OFF, independently of the input signals
and output status, and acts as an inhibit signal.
DARK turns the relay ON and the transistor out-
put "H".
LIGHT turns the relay ON and the transistor out-
put "H".
The response time is set to 2 ms.
The response time is set to 1 ms.
0.1 to 1 s can be set.
1 to 10 s can be set.
DARK ON LIGHT ON
DARK ON LIGHT ON
2 ms (B) 1 ms (A)
2 ms (B) 1 ms (A)
1 sec 10 sec
1 sec 10 sec
Min Max
TIME
Note 1. t must be longer than 1 ms or 2 ms. 2. T denotes a delay time.
T
T
T
T
T
TT
T
T
T
t
Incident light
No incident light
(9)(2)
Release
(9)-(2)
Short circuit
LIGHT ON
DARK ON
LIGHT ON
DARK ON
LIGHT ON
DARK ON
ON D.
OFF D.
O.S.D.
"a"
"b"
"a"
"b"
"a"
"b"
"a"
"b"
"a"
"b"
"a"
"b"
"H"
"L"
"H"
"L"
"H"
"L"
"H"
"L"
"H"
"L"
"H"
"L"
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(ON)
Output
Relay Solid
state
(Output
transistor)
External
synchro-
nous in-
puts
Timer function setting
When select-
ing ON delay
(ON D.)
When select-
ing OFF de-
lay (OFF D.)
When select-
ing one-shot
delay
(O.S.D.)
DARK ON LIGHT ON
2 ms (B)
DELAY
ON D.
1 sec
1 ms (A)
O.S.D.
OFF D.
10 sec
Set a position freel
y
Set a position freel
y
Set a position freel
y
DARK ON LIGHT ON
2 ms (B)
DELAY
ON D.
1 sec
1 ms (A)
O.S.D.
OFF D.
10 sec
Set a position freel
y
Set a position freel
y
Set a position freel
y
DARK ON LIGHT ON
2 ms (B)
DELAY
ON D.
1 sec
1 ms (A)
O.S.D.
OFF D.
10 sec
Set a position freely
Set a position freely
Since the function ha
s
stopped, it allows in
both of the positions.
Set a position freely
E3C
10
Amplifier Units Nomenclature Settings
E3C-JC4P ---
E3C-GE4
Light indicator
(red)
Stability indicator
(green)
Sensitivity adjuster
(4-turn endless asjuster)
Operation selector
Stability indicator
(green)
When the light receiving
input becomes+20% or
more and 20% or less
of operating voltage, it will
be turned on. (Indicate
stable status)
Light indicator
(red)
When the light inputs,
it will be turned on
Sensitivit
ad
uster
Operation switching
Response time changing (The different frequency type can be
made up by changing the response speed.)
* 0 V of power supply
Timing chart
DARK turns the output "H".
LIGHT turns the output "H".
H-0 V * connected The response time is set to 2 ms.
H disconnected The response time is set to 1 ms.
14 4
+
14 4
+
14 4
+
14 4
+
tt
Incident light
No incident light
"H"
"L"
"H"
"L"
No-contact
output
(OFF)
(ON)
(OFF)
(ON)
(Output
transistor)
E3C
11
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product in atmospheres or environments that exceed
product ratings.
Wiring
Connection of E3C-JC4P Amplifier Unit and Sensor
Always run the shielded wires of the Emitter and Receiver separately.
Also, route the sensor cable along the cable grooves of the cover and
sensor and fix it with the cover.
Connection Socket
The standard socket is the PF113A for the E3C-A and -C, and the
PYF08A, PYF08M or PY08 for the E3C-GE4. Avoid using any other
sockets since they may not satisfy the characteristics. (There will be
no problem when the STABILITY indicator turns ON)
Wiring
Extension Cable
The extension distance of the sensor connection cable should be
within 10 m.
The strip-off length of the core in the connection cable should be 20
mm max. on the Receiver side and 50 mm max. on the Emitter side,
and the core should be as short as possible. Avoid using the joint
terminal and connector.
Use independent shielded wires for the Emitter and Receiver.
Using a common shielded wire can cause a malfunction.
Extension Cable
Through-beam
Reflective model
Others
When the E3C is used in a place where high-frequency noise will be
generated, e.g. ultrasonic welder, grounding the 0-V terminal (on the
shield side of the connection cable) of the Receiver may avoid a
malfunction caused by induction.
WARNING
Precautions for Correct Use
Amplifier Units
Sensor Units
Receiver
Emitter
White (Shield)
(Shield) Red
20 mm max.
Socket
Cable Specified cable Replacement
cable
Model
E3C-S10
E3C-1
E3C-2
E3C-S50
Polyethylene insulation shield
Round cable
1-conductor shield/
vinyl wire, conduc-
tor cross section:
0.3 mm2 min.
E3C-S20W
Vinyl insulation shield round cable
1-conductor shield/
vinyl wire, conduc-
tor cross section:
0.3 mm2 min.
E3C-S30T
E3C-S30W
Vinyl insulation shield round cable
(robot cable)
Cable Specified cable Replacement
cable
Model
E3C-DS10
E3C-DS10T
E3C-VS1G
E3C-VS3R
E3C-LS3R
Vinyl insulation shielded parallel ca-
ble
When there is no1-
conductor shielded,
vinyl cable (parallel
wire), use two 1-
conductor shielded,
vinyl wires.
E3C-DS5W
E3C-VS7R
E3C-VM35R
Vinyl insulation shielded parallel ca-
ble When there is no1-
conductor shielded,
vinyl cable (parallel
wire), use two 1-
conductor shielded,
vinyl wires.
2.4 dia.
12-conductor, 0.18 dia.
White (polyethylene)
Shield
White
(vinyl)
Gra
y
(
vin
y
l sheath
)
Shield
1.7 dia.
12-conductor, 0.18 dia.
Sheath
Shield
Polyethylene
Conductor
1.8 dia.
30-conductor, 0.08 dia.
Sheath
Shield
Polyethylene
Conductor
12-conductor, 0.18 dia.
Sheath
Shield
Conductor
Polyethylene
Internal
sheath
2.4
4.3
Sheath
Shield
Polyethylene
Conductor
7-conductor, 0.18 dia.
E3C
12
Dimensions
Sensors
Sensor Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E3C-S10
Emitter: E3C-S10L
Receiver: E3C-S10D
5.8 10
2.3
2.8
2.87.5
Two, 2.9 dia.
2.4-dia. shielded cable with 1 conductor
(Conductor cross section: 0.3 mm2),
Standard len
g
th: 2 m
Light indicator (red)
(emitter only)
12
2
5.2 dia.
Emitter/
receiver surface
E3C-S50
Emitter: E3C-S50L
Receiver: E3C-S50D
13
7
Emitter/receiver label
Two, 3.2 dia.
3.5
5.7 dia.
8
±0.2
2.9
±0.2
11
Emitter/receiver
surface
2.4-dia. shielded cable with 1 conductor
(Conductor cross section: 0.3 mm2),
Standard length: 2 m
Light indicator (red)
(emitter only)
E3C-1
Emitter: E3C-1L
Receiver: E3C-1D
13.5
12
Optical axis position
Emitter/receiver
surface
Iron
12.5
* Mounting Bracket can be attached to side A.
5
103
8 6.4
5.5
2
13
25
3.2
8
12
6 dia.
3.2
16.5
5
4M3
6
3.5
Lens 4 dia.
12
(A)*
2.4-dia. shielded cable with 1 conductor
(Conductor cross section: 0.3 mm2), Standard length: 2 m
Light indicator (red)
(emitter only)
Lens 8 dia.
6.7
23
3.2
5.5
4.5
Iron
3.2
36
12.4 9.4
2
8
12
8 dia.
7
21
Emitter/receiver
surface
13.3 20
17
3.3
* Mounting Bracket can be attached to side A.
(A)*
16
M3 2.4-dia. shielded cable with 1 conductor
(conductor cross section: 0.3 mm
2
), Standard length: 2 m
Optical
axis position
Light indicator (red)
(emitter only)
E3C-2
Emitter: E3C-2L
Receiver: E3C-2D
E3C
13
E3
C
-
S
20W
3.8 dia.
11
±0.2
3.5
2.5
2 dia. (emitter)
Light indicator (red) (Red)(white)
54
4.5 4.5
3.6
18 2 dia. (receiver)
2
2,000
(6) 12.5
2.81.4
2.3 dia.
1.75-dia. shielded cable
with 1 conductor
(Conductor cross section:
0.3 mm2),
Standard length: 2 m
Receiver Emitter
Emitter: E3C-S20LW
Receiver: E3C-S20DW
E3C-S30W
2.2
dia.
4
3.6 dia.
5
7.5
12
2.2
2
8
15
1.5 dia. (receiver)
3
1.5
5
2.4 1.5 dia. (emitter)
1.93-dia. shielded robotics
cable with 1 conductor
(Conductor cross section:
0.15 mm
2
),
Standard length: 2 m
Receiver Emitter
Light indicator
(red) 1.2 dia.
Emitter: E3C-S30LW
Receiver: E3C-S30DW
E3C-S30T
2.2
dia.
15
3.85
5
1.5 dia. (receiver)
3.6 dia.
12
7.5
2.2
7.85
1.5 dia. (emitter)
3
1.5
5
2.4
1.93-dia. shielded robotics
cable with 1 conductor
(Conductor cross section:
0.15 mm2),
Standard length: 2 m
Receiver Emitter
Light indicator
(red) 1.2 dia.
Emitter: E3C-S30LT
Receiver: E3C-S30DT
4
5
Optical axis
position
3.2 10
2.4
6.6
19
3.2
3.9
Receiver
Emitter
Lens
5
1094.3
26 2
8.5±1
15
R3.3
R1.2
2.4-dia. shielded cable
with 2 conductors
(Conductor cross section: 0.3 mm2),
Standard length: 2 m
Light indicator
(red)
E3C-DS10
E3C
14
3.5
2.5
Emitter
Receiver
4
7
±0.2
6
19.5
3.8 dia.
2.8
1.4
2.3 dia.
18
2,000
2
4.5
11
±0.2
40
4
7
1.8 × 3.6-dia. shielded
cable with 2 conductors
(Conductor cross
section: 0.18 mm2),
Standard length: 2 m
E3C-DS5W
E3C-DS10T
16±0.2 Two, 3.2-dia. mounting holes
2.5
Emitter Receiver
2.5
86
40
77±0.2
11
21
1.5
2,000
4.
6
2.4-dia. shielded cable with 2 conductors
(Conductor cross section: 0.3 mm2),
Standard length: 2 m
E3C-LS3R
Emitter Receiver
36 2
1094.3
3.2
6.5
313
±1
Lens
30
Optical axis
position
Light indicator
(red)
5.3
18
2.4
6.6
13
R3.3
R1.2
2.4-dia. shielded cable with 2 conductors
(Conductor cross section: 0.3 mm2),
Standard length: 2 m
E3C
15
Amplifier Units
Accessories (Order Separately)
Mounting Brackets
Refer to E39-L/F39-L/E39-S/E39-R for details.
Connecting Sockets
Refer to E39-L/F39-L/E39-S/E39-R for details.
E3C-A
E3C-C
49
48
48
Operation indicator (red) Stability indicator (green)
Light indicator (red)
51.5
PF113A
4
24.5
109.5
73.5
3
4
6
8
6
E3C-JC4P
50
(10)
5
Two, 3.3 dia.
Operation selector
Caution label*
Sensitivity adjuster
Light indicator
M2.6 Stability indicator
Timer mode selector switch
60
16 R1.6
Mounting bracket (iron) (detachable)
23.5
4310
6
14
12
3.5
30
2.5
35.5
2
3.2
14
*After adjusting the sensitivity, attach the caution label at the location indicated by
above to prevent malfunction.
4.5-dia. vinyl-insulated round cable with
4 conductors (Conductor cross section:
0.2mm2, Insulator diameter: 1.2mm),
Standard length: 2 m
With Mounting Bracket Attached
E3C-GE4
Connector
Use the PYF08A front connection socket
or PY08 rear connection socket.
20.7
Stability indicator (green) Light indicator (red)
35.5 5.4
27.2
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2011.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/