Switch Mode Power Supply
S82S (3/7.5-W Models)
Miniature DIN Rail Mounting DC-DC Power
Supplies
65 mm depth enables mounting onto control panels with
100 mm depth.
Inputs: 10.2 to 27.6 VDC (DC input)
7.5-W models provide both ±12-V and ±15-V outputs.
A complete lineup with 10 different models.
UL and CSA approved.
RoHS-compliant
!Refer to Safety Precautions for All Power Supplies.
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Please refer to List of Models in Ordering Information, below.
Ordering Information
List of Models
Note: For details on normal stock models, contact your nearest OMRON representative.
1 32 1. Input Voltage
7: 12 to 24 VDC
2. Power Ratings
3. Output Voltage
S82S -
3: 3 W
7: 7.5 W
05: 5 V
12: 12 V
15: 15 V
24: 24 V
27: ±12 V
28: ±15 V
Power ratings Output voltage Output current Model
3 W 5 V 0.6 A S82S-7305
12 V 0.25 A S82S-7312
15 V 0.2 A S82S-7315
24 V 0.13 A S82S-7324
7.5 W 5 V 1.5 A S82S-7705
12 V 0.6 A S82S-7712
15 V 0.5 A S82S-7715
24 V 0.3 A S82S-7724
±12 V 0.3 A (+12 V)/0.2 A (–12 V) S82S-7727
±15 V 0.2 A (+15V)/0.2A (–15 V) S82S-7728
S82S
2
Specifications
Ratings/Characteristics
Note: 1. A 100% load for rated input voltage.
2. Output characteristics are measured at the power supply output terminals.
3. If the output voltage adjuster (V.ADJ) is turned, the voltage will increase by more than 50% of the voltage adjustment range. When
adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
4. The settings for the output voltage must be within the following range:
+V: ±1% of the rated value
–V: ±5% of the rated value
5. Refer to Overload Protection on page 4 for details.
Item
DC input
3 W Single output 7.5 W Dual Output 7.5 W
Efficiency (typical) 60% min. 66% min. 64% min.
Input Voltage AC No
DC 10.2 to 27.6 VDC
Current (See note 1.) 0.6 A max. 1.2 A max.
Output
(See note
2.)
Voltage adjustment range ±5% (See note 3.) None (See note 4.)
Ripple (See note 1.) 2% (p-p) max.
Input variation influence 0.5% max.
Load variation influence 1.5% max. +V: 1.5% max.
–V: 3% max.
Temperature variation influence 0.05%/°C max.
Additional
function
Overload protection (See note 5.) 105% min., voltage drop, automatic reset
Other Ambient operating temperature Refer to the derating curve in Engineering Data
Storage temperature 25 to 65°C
Ambient operating humidity 25% to 85% (storage humidity: 20% to 90%)
Dielectric strength 1.5 kVAC for 1 min. (between all input terminals and all output terminals/PE terminals),
current off: 10 mA
Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 294 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: green)
Approved standards Refer to List of Certified Models for details.
Weight 150 g max.
S82S
3
Connections
Block Diagrams
Single Output
Dual Outputs
Construction and Nomenclature
Nomenclature
Terminal Arrangement
Fuse (3 A)
Noise filter
Rectifier
Photocoupler
Detection
Drive
overload
protection
circuit
Fuse (3 A)
Noise filter
Rectifier
Photocoupler
Detection
Rectifier
3-terminal REG
Drive
overload
protection
circuit
5
6
44
111
23 23
S82S-7724
Dual Output ModelsSingle Output Models
1. DC Output Terminals: Connect the load lines to these
terminals.
2. Input Terminals: Connect the input lines to these
terminals.
Note: The fuse is located on the (+V) side. It is NOT user
replaceable.
3. Protective earthing terminal: Connect a ground line to
this terminal.
4. Output LED Indicator (DC OUT ON): Lights while a DC
output is ON (for the Dual Output Models, this indicator is
lit when the +V DC output is ON).
5. Output voltage adjuster (V. ADJ): Use to adjust the
output voltage.
6. NC Terminals: Vacant terminals.
S82S
4
Engineering Data
Derating Curve
Overload Protection
The power supply is provided with an overload protection function
that protects the Power Supply from possible damage by overcurrent.
When the output current rises to 105% or higher of the rated current,
the protection function is triggered, automatically decreasing the
output voltage. When the output current falls within the rated range,
the overload protection function is automatically cleared.
The values shown in the above diagram are for reference only.
Note: Internal parts may occasionally deteriorate or be damaged if a
short-circuit or other overcurrent state continues during
operation. Eliminate the overcurrent state as soon as possible.
Dual Output Models
The total output power for the +V output and V output is detected for
the protection operation (i.e., total overcurrent protection), but this
condition varies depending on –V output status. –V output has an
independent short-circuit protection feature.
Inrush Current, Startup Time,
Hold Time
(A) (B)
Load (%)
Note: The derating curve depends on the mounting direction
of the Power Supply
Standard Mounting Face-up Mounting
20 10 0 10 20 30 40 50 60 70 80
120
100
80
60
40
20
0
Ambient temperature (°C)
(B)
(A)
Output current (%)
100500
Output voltage (V)
90%96.5%
Input ON
Inrush current on input application
100 ms (max.) startup time
Input OFF
AC
input
voltage
AC
input
current
Output
voltage 20 ms (min.)
hold time
S82S
5
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Accessories
Note: All units are in millimeters unless otherwise indicated.
Mounting Bracket
Used when not mounting the Power Supply directly on the DIN Rail.
DIN Rail (Order Separately)
Note: The values shown in parentheses are for the PFP-50N.
* A distance of 7.3 mm is required between the
model and the mounting surface when the
mounting bracket provided with the model is used.
7.3 *
9.8
37.5
±1
75
±1
61 35
65
±1
61
4.6
(Sliding: 7 max.)
Six, M3.5
L27 M4 or 4.5 dia.
Mounting bracket
(provided with the model)
Mounting Holes
S82S-73@@ (3W)
S82S-77@@ (7.5W)
Note: If more than one Power
Supply is installed in a row,
keep a distance of 20 mm
min. (L = 20 mm min.)
between each adjacent
Power Supply.
Mounting Rail (Material: Aluminum)
PFP-100N
PFP-50N
4.5
15 25 25
10 10
1,000 (500)
(see note)
25 25 15 (5)
(see note)
35±0.3
7.3±0.15
27±0.15
1
PFP-100N2
4.5
15 25 25
10 10
1,000
25 25 15 1 1.5
29.2242735±0.3
16
S82S
6
Safety Precautions
!CAUTION
Mounting
To improve and maintain the reliability of the power supply over a
long period of time, adequate consideration must be given to heat
radiation.
The power supply is designed to radiate heat by means of natural air-
flow. Therefore, mount the power supply so that air flow takes place
around the power supply.
When mounting two or more power supplies side-by-side, allow at
least 10 mm spacing between them, as shown in the following
diagram.
Forced air-cooling is recommended.
Wiring
Do not apply more than 75-N force to the terminal block when
tightening it.
DIN Rail Mounting
When mounting to a DIN Rail, lower the S82S onto the Rail until the
Rail stopper clicks into space, hook section A over the edge of the
Rail, and push in the direction of B.
To remove the S82S from the DIN Rail, insert a screwdriver into
section C and pull the S82S away from the Rail.
Serial or Parallel Operation
No serial or parallel operation is available.
The positive and negative output terminals of a Dual Output Model
cannot be connected in series to operate.
Minimum Output Current
(S82S-7727 and S82S-7728)
The minimum output current of the S82S-7727 and S82S-7728 is
restricted by the output voltage and control method.
Note: All the outputs of the S82S-7727 and S82S-7728 are controlled
by the +V output. If the +V output current falls to 10% or less of
the rated output, the –V output voltage may drop.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or repair
the Product or touch the interior of the Product.
Minor burns may occasionally occur. Do not touch the
Product while power is being supplied or immediately
after power is turned OFF.
Fire may occasionally occur. Tighten terminal screws to
the specified torque of 0.74 N·m (M3.5).
Minor injury due to electric shock may occasionally occur.
Do not touch the terminals while power is being supplied.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal or
conductors or any clippings or cuttings resulting from
installation work to enter the Product.
Air
10 mm min.
A
B
Rail stopper
30 mm min.
+V
+V
+V
+V
V
V
V
V
INPUT
INPUT
INPUT
INPUT
Incorrect
Incorrect
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2017.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2017 All Right Reserved.