SECTION 1 Advantages of a 782/Full Featured, Super Series Relay Since the launch of the 700 series relays in 2000, this product line has continuously evolved both functionally and visually. The 700 series product line has the perfect mix of historical Magnecraft relay quality combined with a dynamic arsenal of options. When mated with the Magnecraft sockets and accessories, these RoHs compliant relays provide a complete modular system that will meet all your plugin relay requirements in a package that is both visually appealing and functionally outstanding. Removable Lock-Down Door When Activated, Locks Push Button and Contacts in the Powered Position. Color-Coded Push Button Allows Manual Operation of Relay. AC Coils Red or DC Coils Blue. Finger Grip Cover Easy Removal of Relay from Socket. * Offers a "one stop solution" for your power management system. * Several Contact configurations and materials to meet your individual needs. Contact Viewing Window Shows Position of Contacts. * Plug-In switching capabilities from 10 mA to 20 Amps. * Several Feature Code and Operation combinations available for all budgets. * Ejector clips, ribbed relay housings and space-saving sockets allow for easy removal from crowded DIN rails. Isolated Input and Output Terminals Separates Control Circuits from Load Circuits. Module Compatible Allows for Optional Protection or LED Modules to be Used With Sockets. * Color and appearance designed for high visibility in all environments. * Wiring diagrams include NEMA and IEC standards. 2-Way Side or DIN Rail Mounting System Retrofits Existing Panel Mounting and 35mm DIN Rail. * Engineering availability allows for customized relay solutions. 1/2 www.magnecraft.com 847-441-2540 SECTION 1 Flag Indicator Shows Relay Status in Manual or Powered Condition. Bi-Polar LED Status Lamp Shows Coil "ON" or "OFF" Status. The Complete System Solution! I.D. Tag/Write-On Plastic Label Used for Identification of Relays in Multi-Relay Circuits. Mating Hold-Down Clip Available Secures Relay to Socket. Slim Design Minimizes Space on DIN Rail. Finger-Safe Protects Operators from Live Circuits. Internal Coil Buss Jumper System Allows Connection to Adjacent Sockets Without Additional Wiring. I.D. Tag/Write-On Plastic Label Used to Match Wire Identification Tags with Socket Connections. 1/3 SECTION 1 Advantages of a 782/Plain Cover, Super Series Relay The Plain Cover Super Series relays support budget minded applications with premium performance. Maintaining the same ratings and internal components as the Full Feature Series; the Plain Cover Series perform as well as premium relays while maintaining low costs by offering several option configurations. * Offers a "one stop solution" for your power management system. * Several Contact configurations and materials to meet your individual needs. * Plug-In switching capabilities from 10 mA to 20 Amps. Finger Grip Cover Easy Removal of Relay from Socket. Contact Viewing Window Shows Position of Contacts. Isolated Input and Output Terminals Separates Control Circuits from Load Circuits. Slim Design Minimizes Space on DIN Rail. * Several Feature Code and Operation combinations available for all budgets. * Ejector clips, ribbed relay housings and space-saving sockets allow for easy removal from crowded DIN rails. Mating Hold-Down Clip Available Secures Relay to Socket. * Color and appearance designed for high visibility in all environments. * Wiring diagrams include NEMA and IEC standards. * Engineering availability allows for customized relay solutions. 1/4 www.magnecraft.com 847-441-2540 SECTION 1 Flag Indicator Shows Relay Status in Manual or Powered Condition. The Complete System Solution! Optional Bi-Polar LED Status Lamp Shows Coil "ON" or "OFF" Status. Write-On I.D Label Used for Identification of Relays in Multi-Relay Circuits. Module Compatible Allows for Optional Protection or LED Modules to be Used With Sockets. Finger-Safe Protects Operators from Live Circuits. 2-Way Side or DIN Rail Mounting System Retrofits Existing Panel Mounting and 35 mm DIN Rail. 1/5 SECTION 1 .6 .5) 782 Ice Cube Relays/SPDT, 20 Amp Rating/DPDT 20 Amp Rating Flag indicator Push-To-Test Button Removable lock-down door UL Recognized & Listed When Used With Appropriate Socket. File No. E43641 LED Status Lamp Finger Grip Cover Removable I.D. Tag Contact options for different power levels Contact Viewing Window WHITE General Specifications (UL 508) Contact Characteristics Number and type of Contacts Contact materials Thermal (Carrying) Current Maximum Switching Voltage Switching Current @ Voltage Units ~ ~ Minimum Switching Requirement Coil Characteristics Voltage Range ~ Operating Range ~ Drop-out voltage theshold ~ Performance Characteristics Electrical Life (UL508) Mechanical Life Operating time (response time) Dielectric strength Operations @ Rated Current Unpowered Environment Product certifications Ambient air temperature around the device Vibration resistance Shock resistance Degree of protection 782XAX 1 12 5 14 9 11 13 A1 9(7.4) 11 13 A1 4 42 8 44 12 4 42 8 44 12 41 41 14 A2 NEMA 14 A2 IEC NEMA IEC 1.54 (39.1) 1/12 1 12 5 .83 (21) 14 14 1142 12 41 11 9 12 A1 13 A1 14 A2 11 41 14 1.1 A2 (27.9) 13 A1 14 A2 1 .02 12 5 (0.5) 14 94 8 1344 NEMA IEC NEMA .187Wiring Relay Diagram IEC (4.8) Bottom View 2.6 (6.5) NEMA .08 IEC (2.1)2X 2.61.54 .55 (6.5) (39.1) (14.1) 1.54 (39.1) 100,000 10,000,000 20 2500 1500 1500 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 C C g-n g-n .29 44 (7.4)12 41 9 100,000 10,000,000 20 2500 1500 1500 ms V(rms) V(rms) V(rms) .83 (21) .29 Full Dimensions (7.4)Featured 1 4 .02 42 12 .38 5 8 (0.5) (9.9) 4 42 8 44 6....240 6....125 85% to 110% 80% to 110% 1.2 0.9 15% 10% VA W Standard version Storage Operation Operational 782XBX 6....240 6....125 85% to 110% 80% to 110% 1.2 0.9 15% 10% (Resistive) ~ ~ ~ Between coil and contact Between poles Between contacts 782XBX DPDT Silver Alloy 20 300 20A @ 120V 50/60Hz 20A @ 277V 50/60Hz 20A @ 28V 1/2 @ 120VAC 1 @ 250 VAC B300 100 @ 5VDC (.5W) V V ~ % of Nominal Average consumption 1 12 5 14.29 A V Resistive Resistive Resistive HP HP Pilot Duty mA 782XAX SPDT Silver Alloy 20 300 20A @ 120V 50/60Hz 20A @ 277V 50/60Hz 20A @ 28V 1/2 @ 120VAC 1 @ 250 VAC B300 100 @ 5VDC (.5W) .23 .02 (5.9) (0.5) .187 (4.8) .187 (4.8) .29 (7.4)Plain Cover Dimensions .02 .38 (0.5) (9.9) .29 .83 (21) .16 (4.7) .30 (7.5) .38 (9.9) 1.1 (27.9) 2.6 (6.5) .08 (2.1)2X 1.54 1.4 .55 (39.1) (35.5) (14.1) .16 (4.7) .83 (21) .16 (4.7) .02 .23 (0.5) (5.9) (7.4) 1.1 (27.9) .83 (21) .08 (2.1)2X .187 .55 (4.8) .187 (14.1) (4.8) .23 (5.9) 1.1 (27.9) .30 (7.5) 1.1 (27.9) .3 (7. 782XAX 847-441-2540 782XBX Full Featured Plain Cover Full Featured Standard Part Numbers BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED SPDT Part Number DPDT Part Number DPDT Part Number (Plain Cover) 20 Amp (Full Feature) 20 Amp (Plain Cover) 20 Amp Coil Resistance AC Operated 6 VAC 50/60 HZ 12 VAC 50/60 HZ 24 VAC 50/60 HZ 120 VAC 50/60 HZ 220-240 VAC 50/60 HZ 9.6 Ohms 46 Ohms 180 Ohms 4430 Ohms 15720 Ohms 782XAXM4L-6A 782XAXC-6A 782XBXM4L-6A 782XAXM4L-12A 782XAXC-12A 782XBXM4L-12A 782XAXM4L-24A 782XAXC-24A 782XBXM4L-24A 782XAXM4L-120A 782XAXC-120A 782XBXM4L-120A 782XAXM4L-220/240A 782XAXC-220/240A 782XBXM4L-220/240A 782XBXC-6A 782XBXC-12A 782XBXC-24A 782XBXC-120A 782XBXC-220/240A DC Operated 6 VDC 12 VDC 24 VDC 48 VDC 110-125 VDC 40 Ohms 160 Ohms 650 Ohms 2600 Ohms 11000 Ohms 782XAXM4L-6D 782XAXC-6D 782XBXM4L-6D 782XAXM4L-12D 782XAXC-12D 782XBXM4L-12D 782XAXM4L-24D 782XAXC-24D 782XBXM4L-24D 782XAXM4L-48D 782XAXC-48D 782XBXM4L-48D 782XAXM4L-110/125D 782XAXC-110/125D 782XBXM4L-110/125D 782XBXC-6D 782XBXC-12D 782XBXC-24D 782XBXC-48D 782XBXC-110/125D Custom Relay Part Number Builder 782 XBX Series Contact Configuration 782 SPDT - XAX DPDT - XBX SPDT Part Number (Full Feature) 20 Amp Plain Cover Nominal Voltage Relay Adapters SECTION 1 www.magnecraft.com C Cover Options Full Feature - No Code Plain Cover - C T Terminal Style Plug In - No Code PC terminal - T 240A Coil Voltage VAC = 6 - 240A VDC = 6 - 125D Other mating sockets see Section 2: 70-459-1, 70-401-1, 70-402-1 1.18 (30) 70-782D8-1 SOCKET M4LFeature Options Side Push Button - M Locking Push Button - M4 Bi-Polar LED - L 0.74 (19) 16-1342 Metal Hold-Down Clip 44 14 8 5 44 8 42 12 1 42 4 4 See Section 3 p.10-11 3.14 (80) 0.16 (4) 16-782C1 3.33 (84) 2.67 (68) 1.57 (40) 0.27 (7) 16-782C 2.07 (52) 2.75 (69) INPUT IEC: NEMA: INPUT A2 A1 14 13 41 11 12 9 0.24 (6) 4 1 8 5 12 9 14 13 14 A2 13 A1 IN 12 41 9 11 NEMA IEC 1.06 (26) 1.18 (30) 1/13 SECTION 1 782 Ice Cube Relays/DPDT, 3-10 Amp Rating (DC and AC) Flag indicator Push-To-Test Button Removable lock-down door UL Recognized & Listed When Used With Appropriate Socket. File No. E43641 LED Status Lamp Finger Grip Cover Removable I.D. Tag Contact options for different power levels Contact Viewing Window WHITE General Specifications Units ~ ~ Minimum Switching Requirement Coil Characteristics Voltage Range ~ Drop-out voltage theshold ~ Performance Characteristics Electrical Life (UL508) Mechanical Life Operating time (response time) Dielectric strength Operations @ Rated Current Unpowered Standard version Storage Operation Operational 782XBX2, 3 6 24 9 11 10 21 13 A1 1/14 1 12 53 32 14 4 42 1 12 4 8 4244 7 934 11 11 13 31 A1 8 4412 41 1214 41A2 14 NEMA IECA2 NEMA Relay Wiring Diagram IEC Bottom View Low Level DPDT Bifurcated 3 300 3A @ 120V 50/60Hz 3A @ 277V 50/60Hz 3A @ 30V 1/16 @ 120VAC 6....240 6....125 85% to 100% 80% to 100% 1.2 0.9 15% 10% 6....240 6....125 85% to 100% 80% to 100% 1.2 0.9 15% 10% 200,000 10,000,000 20 1500 1500 1500 100,000 10,000,000 20 1500 1500 1500 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 VA W (Resistive) ~ ~ ~ Between coil and contact Between poles Between contacts Environment Product certifications Ambient air temperature around the device Vibration resistance Shock resistance Degree of protection 5 14 782XBX3 Standard DPDT Silver Alloy 10 300 10A @ 120V 50/60Hz 8A @ 277V 50/60Hz 8A @ 28V 1/3 @ 120VAC 1 @ 277 VAC B300 100 @ 5VDC (.5W) V V ~ % of Nominal Average consumption 2 22 A V Resistive Resistive Resistive HP HP Pilot Duty mA ~ Operating Range 1 12 782XBX2 (UL 508) Contact Characteristics Number and type of Contacts Contact materials Thermal (Carrying) Current Maximum Switching Voltage Switching Current @ Voltage ms V(rms) V(rms) V(rms) C C g-n g-n Full Featured Dimensions 2 22 4 42 1 12 2 22 5 14 6 24 8 44 5 .02 14 (0.5) 9 11 10 21 12 41 9 11 14 A2 13 A1 13 A1 2.6 NEMA (6.5) IEC 1.54 (39.1) 6 24 8 44 10 21 11 31 12 1.1 41 (27.9) .83 (21) Plain Cover Dimensions .83 (21) .02 (0.5) (2 1.1 (27.9) 14 A2 NEMA IEC .24 (6.0) 4 42 3 .83 32 (21) 7 34 10 @ 5VDC (.05W) 2.6 (6.5) 1.4 (35.5) 1.54 (39.1) .24 (6.0) .24 (6.0) NEW NEW NEW NEW NEW Full Featured 847-441-2540 Plain Cover Standard Part Numbers BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED DPDT Part Number DPDT Part Number (Plain Cover) 10 Amp (Full Feature) 3 Amp, Bifurcated Nominal Voltage Coil Resistance AC Operated 6 VAC 50/60 HZ 12 VAC 50/60 HZ 24 VAC 50/60 HZ 120 VAC 50/60 HZ 220-240 VAC 50/60 HZ DPDT Part Number (Full Feature) 10 Amp 9.6 Ohms 46 Ohms 180 Ohms 4430 Ohms 15720 Ohms 782XBX2M4L-6A 782XBX2M4L-12A 782XBX2M4L-24A 782XBX2M4L-120A 782XBX2M4L-220/240A 782XBX2C-6A 782XBX2C-12A 782XBX2C-24A 782XBX2C-120A 782XBX2C-220/240A 782XBX3M4L-6A 782XBX3M4L-12A 782XBX3M4L-24A 782XBX3M4L-120A 782XBX3M4L-220/240A DC Operated 6 VDC 12 VDC 24 VDC 48 VDC 110-125 VDC 40 Ohms 160 Ohms 650 Ohms 2600 Ohms 11000 Ohms 782XBX2M4L-6D 782XBX2M4L-12D 782XBX2M4L-24D 782XBX2M4L-48D 782XBX2M4L-110/125D 782XBX2C-6D 782XBX2C-12D 782XBX2C-24D 782XBX2C-48D 782XBX2C-110/125D 782XBX3M4L-6D 782XBX3M4L-12D 782XBX3M4L-24D 782XBX3M4L-48D 782XBX3M4L-110/125D Custom Relay Part Number Builder XBX 1 782 Contact Config. Contact Code Series DPDT - XBX 3 Amp Fine Silver - Code 1 782 10 Amp Silver Alloy - Code 2 3 Amp Bifurcated - Code 3 C Cover Options Full Feature - No Code Plain Cover - C 3.18 (81) Relay Adapters SECTION 1 www.magnecraft.com T Terminal Style Plug In - No Code PC terminal - T 2.4 (61) 16-782PC-1 Metal Hold-Down Clip M4LFeature Options Side Push Button - M Locking Push Button - M4 Bi-Polar LED - L 70-782EL8-1 SOCKET 1.06 (27) 0.74 (19) See Section 3 p.10-11 3.34 (85) 16-782C1 0.2 (5.6) 240A Coil Voltage VAC = 6 - 240A VDC = 6 - 125D 41 11 12 44 9 14 8 5 42 12 4 1 41 12 11 9 44 8 14 5 42 4 12 1 1 5 4 8 3.11 (79) 12 9 14 13 1.49 (38) A2 IEC: 16-782C NEMA: 0.27 (7) 14 2.04 (52) 2.75 (70) INPUT 0.92 (23.5) A1 13 14 A2 INPUT NEMA IEC 13 A1 1/15 SECTION 1 782 Ice Cube Relays/3PDT, 3-10 Amp Rating (DC and AC) Flag indicator Push-To-Test Button Removable lock-down door UL Recognized & Listed When Used With Appropriate Socket. File No. E43641 LED Status Lamp Finger Grip Cover Removable I.D. Tag Contact options for different power levels Contact Viewing Window WHITE General Specifications Units A V Resistive Resistive Resistive HP HP Pilot Duty mA ~ ~ Minimum Switching Requirement Coil Characteristics Voltage Range ~ Operating Range Average consumption ~ Drop-out voltage theshold ~ Environment Product certifications Ambient air temperature around the device Vibration resistance Shock resistance Degree of protection 1 12 8 44 5 14 12 41 9 11 14 A2 13 A1 MA C 1 12 2 522 14 6 924 11 10 1321 A1 1/16 6....240 6....125 85% to 110% 80% to 110% 1.2 0.9 15% 10% 200,000 10,000,000 20 1500 1500 1500 100,000 10,000,000 20 1500 1500 1500 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 (Resistive) ms V(rms) V(rms) V(rms) ~ ~ ~ 3 32 4 42 24 8 44 5 14 6 24 7 34 8 44 21 12 41 9 11 10 21 11 31 12 41 14 A2 13 A1 IEC Relay Wiring Diagram Bottom View 2.6 (6.5) NEMA 1.54 IEC (39.1) 10 @ 5VDC (.05W) .83 Plain Cover Dimensions Full Featured Dimensions 2 22 12 41 6....240 6....125 85% to 110% 80% to 110% 1.2 0.9 15% 10% C C g-n g-n 1 12 14 NEMAA2 NEMA IEC Between coil and contact Between poles Between contacts 4 42 8 7 34 10 44 11 31 Operations @ Rated Current Unpowered 2 22 4 3 32 6 42 Low Level 3PDT Bifurcated 3 300 3A @ 120V 50/60Hz 3A @ 277V 50/60Hz 3A @ 30V 1/16 @ 120VAC VA W Standard version Storage Operation Operational 782XCX2, 3 4 42 782XCX3 Standard 3PDT Silver Alloy 10 300 10A @ 120V 50/60Hz 8A @ 277V 50/60Hz 8A @ 28V 1/3 @ 120VAC 1 @ 277 VAC B300 100 @ 5VDC (.5W) V V ~ % of Nominal Performance Characteristics Electrical Life (UL508) Mechanical Life Operating time (response time) Dielectric strength 782XCX2 (UL 508) Contact Characteristics Number and type of Contacts Contact materials Thermal (Carrying) Current Maximum Switching Voltage Switching Current @ Voltage (21) .83 (21) .02 (0.5) .02 (0.5) 1.1 (27.9) 1.1 (27.9) 1.1 (27.9) 14 A2 2.6 (6.5) .24 (6.0) 1.54 (39.1) .83 (21) 1.4 .24 (35.5) (6.0) 1.4 (35.5) .24 (6.0) NEW NEW NEW NEW NEW Full Featured Standard Part Numbers 847-441-2540 Plain Cover BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED 3PDT Part Number 3PDT Part Number (Plain Cover) 10 Amp (Full Feature) 3 Amp, Bifurcated Nominal Voltage Coil Resistance AC Operated 6 VAC 50/60 HZ 12 VAC 50/60 HZ 24 VAC 50/60 HZ 120 VAC 50/60 HZ 220-240 VAC 50/60 HZ 3PDT Part Number (Full Feature) 10 Amp 9.6 Ohms 46 Ohms 180 Ohms 4430 Ohms 15720 Ohms 782XCX2M4L-6A 782XCX2M4L-12A 782XCX2M4L-24A 782XCX2M4L-120A 782XCX2M4L-220/240A 782XCX2C-6A 782XCX2C-12A 782XCX2C-24A 782XCX2C-120A 782XCX2C-220/240A 782XCX3M4L-6A 782XCX3M4L-12A 782XCX3M4L-24A 782XCX3M4L-120A 782XCX3M4L-220/240A DC Operated 6 VDC 12 VDC 24 VDC 48 VDC 110-125 VDC 40 Ohms 160 Ohms 650 Ohms 2600 Ohms 11000 Ohms 782XCX2M4L-6D 782XCX2M4L-12D 782XCX2M4L-24D 782XCX2M4L-48D 782XCX2M4L-110/125D 782XCX2C-6D 782XCX2C-12D 782XCX2C-24D 782XCX2C-48D 782XCX2C-110/125D 782XCX3M4L-6D 782XCX3M4L-12D 782XCX3M4L-24D 782XCX3M4L-48D 782XCX3M4L-110/125D Custom Relay Part Number Builder 782 1 XCX Series Contact Code Contact Config. 782 3 Amp Fine Silver - Code 1 3PDT - XCX 10 Amp Silver Alloy - Code 2 3 Amp Bifurcated - Code 3 C Cover Options Full Feature - No Code Plain Cover - C T M4L240A Terminal Style Feature Options Coil Voltage Plug In - No Code Side Push Button - M VAC = 6 - 240A PC terminal - T Locking Push Button - M4 VDC = 6 - 125D Bi-Polar LED - L 3.18 (81) Relay Adapters 16-782C1 SECTION 1 www.magnecraft.com 2.4 (61) 0.74 (19) 70-782EL11-1 SOCKET 3.34 (85) 16-782PC-1 Metal Hold-Down Clip See Section 3 p.10-11 0.2 (5.6) 1.06 (27) 31 9 21 8 11 34 24 7 6 5 14 4 32 22 12 3 2 1 3.11 (79) 31 9 21 8 34 6 24 5 32 3 22 2 3 6 2 5 9 8 14 1.49 (38) A2 IEC: 16-782C A1 NEMA: 14 INPUT 13 0.27 (7) 2.75 (70) 2.04 (52) 0.92 (23.5) 14 A2 1/17 INPU NEM IEC SECTION 1 782 Ice Cube Relays/4PDT, 3-10 Amp Rating (DC and AC) Flag indicator Push-To-Test Button Removable lock-down door UL Recognized & Listed When Used With Appropriate Socket. File No. E43641 LED Status Lamp Finger Grip Cover Removable I.D. Tag Contact options for different power levels Contact Viewing Window WHITE General Specifications (UL 508) Contact Characteristics Number and type of Contacts Contact materials Thermal (Carrying) Current Maximum Switching Voltage Switching Current @ Voltage Units A V Resistive Resistive Resistive HP HP Pilot Duty mA ~ ~ Minimum Switching Requirement Coil Characteristics Voltage Range ~ Operating Range ~ % of Nominal Average consumption ~ Drop-out voltage theshold ~ Performance Characteristics Electrical Life (UL508) Mechanical Life Operating time (response time) Dielectric strength Environment Product certifications Ambient air temperature around the device Vibration resistance Shock resistance Degree of protection 782XDX2, 3 4 42 2 22 3 32 4 42 8 44 1 12 52 14 22 63 24 32 7 4 34 42 8 44 12 41 5 14 96 24 11 7 10 34 21 8 11 44 31 12 41 14 A2 9 11 13 10 21 A1 11 31 12 41 14 A2 1/18 Operations @ Rated Current Unpowered Between coil and contact Between poles Between contacts VA W (Resistive) ~ ~ ~ Standard version Storage Operation Operational 1 12 13 A1 V V NEMA14 IEC A2 NEMA Relay Wiring Diagram IEC Bottom View ms V(rms) V(rms) V(rms) C C g-n g-n 782XDX2 782XDX3 Standard 4PDT Silver Alloy 10 300 10A @ 120V 50/60Hz 8A @ 277V 50/60Hz 8A @ 28V 1/3 @ 120VAC 1 @ 277 VAC B300 100 @ 5VDC (.5W) Low Level 4PDT Bifurcated 3 300 3A @ 120V 50/60Hz 3A @ 277V 50/60Hz 3A @ 30V 1/16 @ 120VAC 6....240 6....125 85% to 110% 80% to 110% 1.2 0.9 15% 10% 6....240 6....125 85% to 110% 80% to 110% 1.2 0.9 15% 10% 200,000 10,000,000 20 1500 1500 1500 200,000 10,000,000 20 1500 1500 1500 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 UL, CSA, CE -40...+85 -40...+55 3, 10 - 55 Hz 10 IP 40 .83 (21) Full Featured Dimensions 10 @ 5VDC (.05W) .83 (21) Plain Cover Dimensions .02 (0.5).83 (21) .83 (21) 1.1 (27.9) 1.1 (27.9) .02 (0.5) 1.1 (27.9) 1.1 (27.9) 2.6 (6.5) 2.6 (6.5) 1.54 (39.1) 1.54 (39.1) .24 (6.0) .24 (6.0) 1.4 (35.5) 1.4 (35.5) .24 (6.0) .24 (6.0) Full Featured 847-441-2540 SECTION 1 www.magnecraft.com Plain Cover Standard Part Numbers BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED 4PDT Part Number 4PDT Part Number (Full Feature) 3 Amp, Bi-Furcated (Plain Cover) 10 Amp Nominal Voltage Coil Resistance AC Operated 6 VAC 50/60 HZ 12 VAC 50/60 HZ 24 VAC 50/60 HZ 120 VAC 50/60 HZ 220-240 VAC 50/60 HZ 4PDT Part Number (Full Feature) 10 Amp 9.6 Ohms 46 Ohms 180 Ohms 4430 Ohms 15720 Ohms 782XDX2M4L-6A 782XDX2M4L-12A 782XDX2M4L-24A 782XDX2M4L-120A 782XDX2M4L-220/240A 782XDX2C-6A 782XDX2C-12A 782XDX2C-24A 782XDX2C-120A 782XDX2C-220/240A 782XDX3M4L-6A 782XDX3M4L-12A 782XDX3M4L-24A 782XDX3M4L-120A 782XDX3M4L-220/240A DC Operated 6 VDC 12 VDC 24 VDC 48 VDC 110-125 VDC 40 Ohms 160 Ohms 650 Ohms 2600 Ohms 11000 Ohms 782XDX2M4L-6D 782XDX2M4L-12D 782XDX2M4L-24D 782XDX2M4L-48D 782XDX2M4L-110/125D 782XDX2C-6D 782XDX2C-12D 782XDX2C-24D 782XDX2C-48D 782XDX2C-110/125D 782XDX3M4L-6D 782XDX3M4L-12D 782XDX3M4L-24D 782XDX3M4L-48D 782XDX3M4L-110/125D Custom Relay Part Number Builder XDX 1 782 Contact Config. Contact Code Series 4PDT - XDX 3 Amp Fine Silver - Code 1 782 10 Amp Silver Alloy - Code 2 3 Amp Bifurcated - Code 3 C Cover Options Full Feature - No Code Plain Cover - C T Terminal Style Plug In - No Code PC terminal - T M4LFeature Options Side Push Button - M Locking Push Button - M4 Bi-Polar LED - L 240A Coil Voltage VAC = 6 - 240A VDC = 6 - 125D Other mating sockets see Section 2: 70-782EL14-1, 70-782E14-1, 70-461-1, 70-378-1, 70-379-1, Relay Adapters 1.57 (40) 70-782D14-1 SOCKET 1.0 (25.5) 0.14 (3.8) 0.74 (19) 16-782SC Metal Hold-Down Clip See Section 3 p.10-11 3.11 (79) 16-782C1 3.3 (84) 34 7 24 6 44 14 8 5 42 32 22 4 3 2 34 7 44 8 1 4 A2 A1 INPUT INPUT 14 2.08 (53) 16-782C 2.71 (69) 22 2 3 2 7 6 12 11 10 11 1.18 (30) 32 3 8 2.4 (61) 0.14 (3.8) 0.27 (7) 42 4 12 13 41 31 21 12 11 10 0.82 (21) 1.18 (30) 14 1.55 (39.5) 9 13 A1 14 A2 0.25 (6.4) 12 41 11 10 31 21 NEMA IEC 1/19