EQ-731L
●Electriccharacteristics(TA=25℃,VCC=5V)
●Magneticcharacteristics(TA=25℃,VCC=5V)
※1mT=10Gauss
※1mT=10Gauss
Parameter
Conditions min Unit
Symbol
VCC−0.3
0
9
210
1
2
0.3
5
12
VCC
0.3
mA
V
V
kHz
μs
μs
μs
mVp-p
Typ Max
OutputsaturationvoltageatLowLevel
(*1)
Bandwidth
(*2)
Response time(*2)
Output rise time(*2)
Output fall time(*2)
Output noise voltage
(*2)
B=0mTwithnoload
IOUT=ー1mA
IOUT=1mA
ー3dB CL=1000pF
ICC
VSATH
VSATL
fT
tRES
tRISE
tFALL
tREAC
VNp-p
OutputsaturationvoltageatHighLevel
(*1)
Current consumption
(*1&2)Designtargetat25℃
(*3)SeeCharacteristicDefinitionssection
(*4)SeeCharacteristicDefinitionssection
Risetime:10%ofInputMFDto90%ofoutputvoltage.
Falltime:90%ofInputMFDto10%ofoutputvoltage.
(underinput/outputMFDstepis1to2μs)
CL=1000pF
Output delay time(*2)
Risetime:10%ofInputMFDto10%ofoutputvoltage.
Falltime:90%ofInputMFDto90%ofoutputvoltage.
(underinput/outputMFDstepis1to2μs)
CL=1000pF
10%to90%ofoutputvoltageunder
input/outputMFDstepis1to2μs.
CL=1000pF
90%to10%ofoutputvoltageunder
input/outputMFDstepis1to2μs
CL=1000pF
●Ratio-metriccharacteristics(TA=25℃)
※1mT=10Gauss
(*5)SeeCharacteristicDefinitionssection
Parameter
Symbol
Conditions min Typ Max Unit
Sensitivity(*3)
Quiescent voltage
Linearity(*4)
Vh
VOUT0
ρ
B=0、±22mTwithnoload
B=0mT
B=0mT(IOUT=0mA)
B=±27mT(IOUT=±1mA)
55
2.35
−0.5
65
2.5
75
2.65
0.5
mV/mT
V
%F.S.
Parameter
Symbol
Conditions min Typ Max Unit
ErrorinRatiometricof
Magneticsensitivity
(*5)
ErrorinRatiometricof
Quiescentvoltage
(*5)
V
OUT0-R
Vh-R B=0、±22mTwithnoload
B=0mT
−3
−3
3
3
%
%
Inputmagneticfield
Risetimeofmagneticfield Falltimeofmagneticfield
tRES
tREA tREA tFALL
tRES
tRISE
Outputvoltage
ofsensor
90% 90%
10%
90%
1〜2μs 1〜2μs
10%
90%
10%
10%
●CharacteristicDefinitions
ρ= ×100
Vout(+B)ーVout(ーB)
Vout(B)ー{Vh×B+Vint}
①MagneticsensitivityVh(mV/mT)
Magneticsensitivityisdefinedastheslopeofthestraightline
obtained from three points, Quiescent voltage VOUT0、VOUT
(+B)、VOUT(−B)(B isdescribed inmeasurementcondition),
bytheleastsquareapproximation.
②Linearityρ(%F.S.)
Linearity is defined as the ratio of a error voltage against
FULLSCALE. Where error voltage is calculate as the
difference from the straight line obtained from three points,
Quiescent voltage VOUT0、VOUT(+B)、VOUT (−B) (B and
Output current are described in measurement condition
shownbelow),bytheleastsquareapproximation.
〈Condition〉:0mTapplied、IOUT=0mA
+BmTapplied:IOUT=+1.0mA(Drawoutfromoutput)
−BmTapplied:IOUT=−1.0mA(Drawintooutput)
WhereFULLSCALE(F.S.)isdefiedasVOUT(+B)、VOUT(−B),
Vint is y-intercepts of the line obtained in the Definition of
Magneticsensitivity.
③Error in Ratiometric of Magnetic sensitivity and Error in
Ratiometricofquiescentvoltage
Errorinratiometricisdefinedastheratioofthevariationof
sensitivityand quiescentvoltage at3Vand5Vas following
equations..
④Responsetime tRES(μs)
Response time is defined as the time from the 90% reach
pointofinputmagneticfieldriseuptothe90%reachpointof
outputvoltageriseup
⑤Outputrisetime,Outputfalltime tRISE、tFALL(μs )
Outputriseuptimeisdefinedasthetimefromthe10%point
to the 90% point of output voltage under a pulse like
magneticfieldinputshownbelow.
Output fall down time is defined as the time from the 90%
point to the 10% point of output voltage under a pulse like
magneticfieldinputshownbelow.
⑥Outputdelaytime tREAC(μs )
Outputdelaytimeisdefinedasthetimefromthe10%point
inrise up(90% pointin falldown) of inputmagnetic fieldto
the 10% point in rise up(90% point in fall down) of output
voltageunderapulselikemagneticfieldinputshownbelow..
〈Relations of the input Magnetic field and tRES、tRISE、tFALL、
tREAC〉
VhーR= ×100
Vh(VCC=5V)5
3
5
3
Vh(VCC=3V)
−
VOUT0ーR= ×100
VOUT0(VCC=5V)5
3
5
3
VOUT0(VCC=3V)
−