Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions. 141
Power Supplies
Linear OEM – Single Output
UL 601950-1
E137632
Features
Low noise output
115/230 Vac input
Remote sensing
Designed for both bench and rack use
Completely protected short circuit proof; automatic
foldback.
Current limiting – automatic reset
Isolated oating output
UL Recognized, CSA Certied
Built-in OVP on 5 Volt models
Terminal block on Case D models (24 V/6 A)
One year warranty
Applications
Microprocessor Circuits Instrumentation
Process Controls CNC Machinery
Control Circuits Analog Circuits
Noise sensitive Circuits
Specifications
Selection Table
Catalog Number Output 1 Case
83-05-230-3 5 V @ 3.0 A B
83-12-218-3 12 V @ 1.8 A B
83-24-212-3 24 V @ 1.2 A B
83-24-225-3 24 V @ 2.5 A C
83-05-312-3 5 V @ 12 A D
83-12-310-3 12 V @ 10 A D
83-24-260-3 24 V @ 6 A D
Parameter Condition Limit
Input
Input Voltage 104-127 Vac
208-254 Vac
Input Frequency 50-60 Hz
Output
Regulation Line & Load ±0.1%
Pard (Ripple and Noise) 0.1% pk/pk
Periodic Deviations
(Ripple) 10mv rms
Output Voltage
Adjustment ±5% Minimum
Transient
Recovery Time 50%-100% Load Less than 50 msec
General
Storage Ambient Temp. -40°C to +85°C
Operating Ambient Temp. 0°C to +50°C
Temp. Effect Coefficient 0.03% °C
Polarity May be used
positive or negative
Short Circuit Protection Protected with
Automatic Recovery
Maximum Allowable
Lead Drop for Remote
Sensing
5%
Maximum Output Current 120% Rated Current
Maximum Short Circuit
Current 30% Rated Current
Input/Output Isolation 1000 Megohms D.C.,
2500 Vac
Cooling Forced air. 20 CFM required for full rating
Derate 30% without cooling